Performance Analysis of Flat-Plate Solar Collector Having Silver Nanofluid as a Working Fluid

被引:34
作者
Polvongsri, Sarawut [1 ]
Kiatsiriroat, Tanongkiat [2 ]
机构
[1] Chiang Mai Univ, Grad Sch, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Dept Engn Mech, Fac Engn, Chiang Mai 50200, Thailand
关键词
HEAT-PIPE; THERMAL-CONDUCTIVITY; NANO-FLUID; ENHANCEMENT; EFFICIENCY;
D O I
10.1080/01457632.2013.870003
中图分类号
O414.1 [热力学];
学科分类号
摘要
A study on water solar collector performance having silver nanofluid as working fluid was carried out. In this study, 20-nm silver particles mixed with water at the concentrations of 1,000 and 10,000 ppm were undertaken in 3 small identical closed-loop flat-plate solar collectors, each with an area of 0.15 m x 1.0 m. The mass flux of the working fluid varied between 0.8 and 1.2 L/min-m(2) and the inlet temperatures were controlled in the range of 35-65 degrees C. The tests were performed outdoor under a steady-state condition. The experimental results showed that at the same Reynolds number, the convective heat transfer coefficient of the nanofluid inside the solar absorber tube at 1,000 ppm was slightly higher than that of water, and at 10,000 ppm, the heat transfer coefficient was about 2 times that of water. This meant that the overall heat loss coefficient of the solar collector with nanofluid could be reduced and more solar heat gain could be obtained, especially with a high inlet temperature of the working fluid. In our experiments, for 10,000 ppm concentration of silver nanoparticles, the optical characteristic and the thermal loss characteristic of the solar collector, under steady-state condition with a mass flux of 1.2 kg/min-m(2), were 0.691 and 4.869 W/m(2)-K, compared with 0.684 and 7.178 W/m(2)-K, respectively for 1,000 ppm concentration and 0.702 and 8.318 W/m(2)-K for water. When the flow rate was different from the standard value, the solar thermal characteristics were also improved with the nanofluid.
引用
收藏
页码:1183 / 1191
页数:9
相关论文
共 19 条
[1]  
ASHRAE Standard, 2003, METH TEST DET THERM
[2]  
Duffie J.A., 1994, Solar Engineering of Thermal Processes
[3]  
Heaton H.S., 1964, INT J HEAT MASS TRAN, V7, P763
[4]   Flow and convective heat transfer characteristics of water-based Al2O3 nanofluids in fully developed laminar flow regime [J].
Hwang, Kyo Sik ;
Jang, Seok Pil ;
Choi, Stephen U. S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (1-2) :193-199
[5]   Experimental investigation of silver nano-fluid on heat pipe thermal performance [J].
Kang, Shung-Wen ;
Wei, Wei-Chiang ;
Tsai, Sheng-Hong ;
Yang, Shih-Yu .
APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) :2377-2382
[6]   Experimental investigation of nanofluids on sintered heat pipe thermal performance [J].
Kang, Shung-Wen ;
Wei, Wei-Chiang ;
Tsai, Sheng-Hong ;
Huang, Chia-Ching .
APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) :973-979
[7]   A new thermal conductivity model for nanofluids [J].
Koo, J ;
Kleinstreuer, C .
JOURNAL OF NANOPARTICLE RESEARCH, 2004, 6 (06) :577-588
[8]   Effect of silver nano-fluid on pulsating heat pipe thermal performance [J].
Lin, Yu-Hsing ;
Kang, Shung-Wen ;
Chen, Hui-Lun .
APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) :1312-1317
[9]  
Malawanno N., 2008, P 7 C HEAT MASS TRAN, V7, P30
[10]   Effect of nanoparticles mean diameter on mixed convection heat transfer of a nanofluid in a horizontal tube [J].
Mirmasoumi, S. ;
Behzadmehr, A. .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2008, 29 (02) :557-566