Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data

被引:4
作者
Yoshimura, Takaaki [1 ,2 ]
Shimizu, Shinichi [3 ,4 ]
Hashimoto, Takayuki [3 ]
Nishioka, Kentaro [3 ]
Katoh, Norio [4 ,5 ]
Taguchi, Hiroshi [4 ,5 ]
Yasuda, Koichi [4 ,5 ]
Matsuura, Taeko [6 ]
Takao, Seishin [2 ]
Tamura, Masaya [2 ]
Tanaka, Sodai [6 ]
Ito, Yoichi M. [2 ,7 ]
Matsuo, Yuto [2 ]
Tamura, Hiroshi [2 ]
Horita, Kenji [2 ]
Umegaki, Kikuo [6 ]
Shirato, Hiroki [4 ,8 ]
机构
[1] Hokkaido Univ, Fac Hlth Sci, Dept Hlth Sci & Technol, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ Hosp, Proton Beam Therapy Ctr, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Fac Med, Dept Radiat Med Sci & Engn, Sapporo, Hokkaido, Japan
[4] Hokkaido Univ, Global Inst Collaborat Res & Educ GI CoRE, Global Stn Quantum Med Sci & Engn, Sapporo, Hokkaido, Japan
[5] Hokkaido Univ, Fac Med, Dept Radiat Oncol, Sapporo, Hokkaido, Japan
[6] Hokkaido Univ, Fac Engn, Sapporo, Hokkaido, Japan
[7] Inst Stat Math, Dept Stat Data Sci, Tokyo, Japan
[8] Hokkaido Univ, Fac Med, Res Ctr Cooperat Projects, Dept Proton Beam Therapy, Sapporo, Hokkaido, Japan
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2020年 / 21卷 / 12期
基金
日本学术振兴会;
关键词
spot‐ scanning proton beam therapy; organ motion; beam delivery efficiency; treatment time; MULTIPLE-ENERGY OPERATION; TUMOR-TRACKING; TREATMENT UNCERTAINTIES; DELIVERY; MOTION; LUNG; RADIOTHERAPY; DESIGN; OPTIMIZATION; SENSITIVITY;
D O I
10.1002/acm2.13029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A synchrotron-based real-time image gated spot-scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra-field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron-based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron-based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra-field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron-based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within +/- 2.0 mm, intra-field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 45 条
  • [1] Relation of external surface to internal tumor motion studied with cine CT
    Chi, Pai-Chun Melinda
    Balter, Peter
    Luo, Dershan
    Mohan, Radhe
    Pan, Tinsu
    [J]. MEDICAL PHYSICS, 2006, 33 (09) : 3116 - 3123
  • [2] The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center
    Chung, Kwangzoo
    Han, Youngyih
    Kim, Jinsung
    Ahn, Sung Hwan
    Ju, Sang Gyu
    Jung, Sang Hoon
    Chung, Yoonsun
    Cho, Sungkoo
    Jo, Kwanghyun
    Shin, Eun Hyuk
    Hong, Chae-Seon
    Shin, Jung Suk
    Park, Seyjoon
    Kim, Dae-Hyun
    Kim, Hye Young
    Lee, Boram
    Shibagaki, Gantaro
    Nonaka, Hideki
    Sasai, Kenzo
    Koyabu, Yukio
    Choi, Changhoon
    Huh, Seung Jae
    Ahn, Yong Chan
    Pyo, Hong Ryull
    Lim, Do Hoon
    Park, Hee Chul
    Park, Won
    Ryul, Dong
    Noh, Jae Myung
    Yu, Jeong Il
    Song, Sanghyuk
    Lee, Ji Eun
    Lee, Bomi
    Choi, Doo Ho
    [J]. RADIATION ONCOLOGY JOURNAL, 2015, 33 (04): : 337 - 343
  • [3] Optimizing mini-ridge filter thickness to reduce proton treatment times in a spot-scanning synchrotron system
    Courneyea, Lorraine
    Beltran, Chris
    Tseung, Hok Seum Wan Chan
    Yu, Juan
    Herman, Michael G.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [4] Reduction of the number of stacking layers in proton uniform scanning
    Fujitaka, Shinichiro
    Takayanagi, Taisuke
    Fujimoto, Rintaro
    Fujii, Yusuke
    Nishiuchi, Hideaki
    Ebina, Futaro
    Okazaki, Takashi
    Hiramoto, Kazuo
    Sakae, Takeji
    Terunuma, Toshiyuki
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) : 3101 - 3111
  • [5] MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY
    HABERER, T
    BECHER, W
    SCHARDT, D
    KRAFT, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) : 296 - 305
  • [6] Multiple-energy operation with extended flattops at HIMAC
    Iwata, Y.
    Kadowaki, T.
    Uchiyama, H.
    Fujimoto, T.
    Takada, E.
    Shirai, T.
    Furukawa, T.
    Mizushima, K.
    Takeshita, E.
    Katagiri, K.
    Sato, S.
    Sano, Y.
    Noda, K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (01) : 33 - 38
  • [7] Impact of Real-Time Image Gating on Spot Scanning Proton Therapy for Lung Tumors: A Simulation Study
    Kanehira, Takahiro
    Matsuura, Taeko
    Takao, Seishin
    Matsuzaki, Yuka
    Fujii, Yusuke
    Fujii, Takaaki
    Ito, Yoichi M.
    Miyamoto, Naoki
    Inoue, Tetsuya
    Katoh, Norio
    Shimizu, Shinichi
    Umegaki, Kikuo
    Shirato, Hiroki
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 97 (01): : 173 - 181
  • [8] Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion
    Knopf, Antje-Christin
    Boye, Dirk
    Lomax, Antony
    Mori, Shininchiro
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (17) : 6079 - 6094
  • [9] Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics
    Knopf, Antje-Christin
    Hong, Theodore S.
    Lomax, Antony
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22) : 7257 - 7271
  • [10] Initial Report of Pencil Beam Scanning Proton Therapy for Posthysterectomy Patients With Gynecologic Cancer
    Lin, Lilie L.
    Kirk, Maura
    Scholey, Jessica
    Taku, Nicolette
    Kiely, Janid B.
    White, Benjamin
    Both, Stefan
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 181 - 189