Trochanteric transfer in total hip replacement: Effects on the moment arms and force-generating capacities of the hip abductors

被引:24
作者
Free, SA
Delp, SL
机构
[1] REHABIL INST CHICAGO, SENSORY MOTOR PERFORMANCE PROGRAM 1406, CHICAGO, IL 60611 USA
[2] NORTHWESTERN UNIV, DEPT BIOMED ENGN, CHICAGO, IL USA
[3] NORTHWESTERN UNIV, DEPT PHYS MED & REHABIL, CHICAGO, IL USA
关键词
D O I
10.1002/jor.1100140212
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A three-dimensional computer model of the pelvis, femur, gluteus medius, and gluteus minimus was used to evaluate the changes in muscle moment arms and force-generating capacities caused by alterations in the location of the greater trochanter. In the first part of this study, the hip center and all other aspects of joint geometry remained unaltered, while we examined changes in abduction moment arms that resulted from transfer of the trochanteric fragment to a wide variety of positions on the femur. The largest increase in average abduction moment arm was 11% (0.5 cm), which occurred with an anterolateral transfer. Most transfers resulted in moment arm changes of less than 5%. In the second part of this study, the hip center was displaced 2 cm superiorly and the effects of a distal trochanteric transfer on the moment arms and force-generating capacities of the abductors were analyzed. The superior displacement caused a 13% decrease in the moment arm of the abductors and a 43% decrease in their force-generating capacity. The moment arm was not restored by distal transfer of the greater trochanter; however, distal transfer had the major advantage of restoring muscle lengths and force-generating capacities. These results suggest that trochanteric transfer should be considered primarily as a means to restore muscle length because it has limited potential to increase the moment arms of the two primary hip abductors.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 27 条
[1]  
BORJA F, 1985, CLIN ORTHOP RELAT R, V197, P181
[2]   THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA [J].
BRAND, RA ;
PEDERSEN, DR ;
FRIEDERICH, JA .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :589-596
[3]   TRANSPLANTATION OF THE GREATER TROCHANTER IN ARTHROPLASTY OF THE HIP [J].
CHARNLEY, J ;
FERREIRA, ADD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1964, 46 (02) :191-197
[4]   SUPERIOR DISPLACEMENT OF THE HIP IN TOTAL JOINT REPLACEMENT - EFFECTS OF PROSTHETIC NECK LENGTH, NECK-STEM ANGLE, AND ANTEVERSION ANGLE ON THE MOMENT-GENERATING CAPACITY OF THE MUSCLES [J].
DELP, SL ;
KOMATTU, AV ;
WIXSON, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (06) :860-870
[5]   EFFECTS OF HIP CENTER LOCATION ON THE MOMENT-GENERATING CAPACITY OF THE MUSCLES [J].
DELP, SL ;
MALONEY, W .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :485-499
[6]   AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES [J].
DELP, SL ;
LOAN, JP ;
HOY, MG ;
ZAJAC, FE ;
TOPP, EL ;
ROSEN, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) :757-767
[7]  
DELP SL, 1990, CLIN ORTHOP RELAT R, V254, P189
[8]  
EFTEKHAR NS, 1978, PRINCIPLES TOTAL HIP, P35
[9]   TROCHANTERIC APPROACH TO HIP FOR PROSTHETIC REPLACEMENT [J].
ENGLISH, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (08) :1128-1133
[10]  
FRANKEL A, 1993, CLIN ORTHOP RELAT R, P209