Patent Foramen Ovale Closure With the Gore Septal Occluder: Initial UK Experience

被引:11
|
作者
Thomson, John D. [1 ]
Hildick-Smith, David [2 ]
Clift, Paul [3 ]
Morgan, Gareth [4 ]
Daniels, Matthew [5 ,6 ]
Henderson, Robert [7 ]
Spence, Mark S. [8 ]
Mahadevan, Vaikom S. [9 ]
Crossland, David [10 ]
Ormerod, Oliver [5 ]
机构
[1] Leeds Gen Infirm, Dept Congenital Cardiol, Leeds LS1 3EX, W Yorkshire, England
[2] Sussex Cardiac Ctr, Dept Cardiol, Brighton, E Sussex, England
[3] Queen Elizabeth Hosp, Dept Adult Congenital Heart Dis, Birmingham B15 2TH, W Midlands, England
[4] Bristol Heart Inst, Dept Congenital Cardiol, Bristol, Avon, England
[5] John Radcliffe Hosp, Dept Cardiovasc Med, Oxford OX3 9DU, England
[6] Univ Oxford, Radcliffe Dept Med, Div Cardiovasc Med, Oxford, England
[7] Univ Nottingham Hosp, Trent Cardiac Ctr, Dept Cardiol, Nottingham NG7 2UH, England
[8] Royal Victoria Hosp, Dept Cardiol, Belfast BT12 6BA, Antrim, North Ireland
[9] Manchester Royal Infirm, Dept Cardiol, Manchester M13 9WL, Lancs, England
[10] Freeman Rd Hosp, Dept Paediat Cardiol, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
基金
英国惠康基金;
关键词
patent foramen ovale; atrial septal defect; congenital heart; disease in adults; cerebrovascular accident; TRANSCATHETER CLOSURE; ATRIAL-FIBRILLATION; CRYPTOGENIC STROKE; PERCUTANEOUS CLOSURE; DEVICES; PFO;
D O I
10.1002/ccd.25063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesTo report procedural outcome and short-term follow-up data for the Gore septal occluder (GSO), a new device for closure of patent foramen ovale (PFO). BackgroundTranscatheter closure of PFO is an established treatment modality but no current device provides a perfect solution. The GSO has a number of design features, which make it potentially attractive for closure of defects in the atrial septum. MethodsData from 9 centers in the United Kingdom implanting the GSO device, submitted to an electronic registry for evaluation. ResultsTwo hundred twenty-nine patients undergoing PFO closure from June 2011 to October 2012 were included. Indications for closure were secondary prevention of paradoxical cerebral emboli (83.4%), migraine (2.1%), platypnoea orthodeoxia (3.9%), and other (10.5%). Median PFO size was 8 mm and 34 and 39%, respectively, had long tunnel anatomy or atrial septal aneurysms. A GSO was successfully implanted in all cases. A single device was used in 98% but in 4 patients the initial device was removed and a second device required. Procedural complications occurred in 3% and later complications (e.g., atrial fibrillation, atrial ectopics, and device thrombus) in 5.7% of cases. All patients have undergone clinical and echocardiographic follow-up and all devices remain in position. Early bubble studies (median 0 months) with Valsalva maneuver in 67.2% were negative in 89%. ConclusionsThe GSO is an effective occlusion device for closure of PFO of all types. Longer-term follow-up particularly to document later closure rates are required. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 50 条
  • [21] AMPLATZER versus Figulla occluder for transcatheter patent foramen ovale closure
    Trabattoni, Daniela
    Gaspardone, Achille
    Sgueglia, Gregory A.
    Fabbiocchi, Franco
    Gioffre, Gaetano
    Montorsi, Piero
    Calligaris, Giuseppe
    Iamele, Maria
    De Santis, Antonella
    Bartorelli, Antonio L.
    EUROINTERVENTION, 2017, 12 (17) : 2092 - 2099
  • [22] Initial Clinical Experience With the GORE® CARDIOFORM ASD Occluder for Transcatheter Atrial Septal Defect Closure
    de Hemptinne, Quentin
    Horlick, Eric M.
    Osten, Mark D.
    Millan, Xavier
    Tadros, Victor-Xavier
    Pighi, Michele
    Barlatey, Francisco Gonzalez
    Alnasser, Sami M.
    Miro, Joaquim
    Asgar, Anita W.
    Ibrahim, Reda
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (03) : 495 - 503
  • [23] Patent foramen ovale closure for secondary stroke prevention
    Alkhouli, Mohamad
    Sievert, Horst
    Holmes, David R.
    EUROPEAN HEART JOURNAL, 2019, 40 (28) : 2339 - +
  • [24] Patent foramen ovale and atrial septal defect
    Kheiwa, Ahmed
    Hari, Pawan
    Madabhushi, Pranav
    Varadarajan, Padmini
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (12): : 2172 - 2184
  • [25] Residual Shunt after Patent Foramen Ovale Closure: Preliminary Results from Italian Patent Foramen Ovale Survey
    Caputi, Luigi
    Butera, Gianfranco
    Anzola, Gian Paolo
    Carminati, Mario
    Carriero, Maria Rita
    Chessa, Massimo
    Onorato, Eustaquio
    Rigatelli, Gianluca
    Sangiorgi, Giuseppe
    Santoro, Gennaro
    Spadoni, Isabella
    Ussia, Gian Paolo
    Vigna, Carlo
    Zanchetta, Mario
    Parati, Eugenio
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2013, 22 (07) : E219 - E226
  • [26] First experience with the new GORE® septal occluder for the closure of multiple atrial septal defects
    Freixa, Xavier
    Garceau, Patrick
    Asgar, Anita W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1238 - 1242
  • [27] Patent Foramen Ovale Stroke and Device Closure
    Suradi, Hussam S.
    Hijazi, Ziyad M.
    CARDIOLOGY CLINICS, 2016, 34 (02) : 231 - +
  • [28] Recent development of transcatheter closure of atrial septal defect and patent foramen ovale with occluders
    Tang, Baiyu
    Su, Feng
    Sun, Xiangke
    Wu, Qin
    Xing, Quansheng
    Li, Suming
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (01) : 433 - 443
  • [29] Transient heart block following patent foramen ovale and atrial septal defect closure with Gore cardioform devices
    Devanagondi, Rajiv
    Leonard, Glenn
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2022, 66
  • [30] Experience in patent foramen ovale closure with the CERA Lifetech occluder in patients with cryptogenic stroke
    Weglarz, Przemyslaw
    Wegiel, Michal
    Konarska-Kuszewska, Ewa
    Kuszewski, Piotr
    Staszel, Michal
    Dziewierz, Artur
    Rakowski, Tomasz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2023, 19 (03): : 257 - 261