Characterization of a new radiochromic three-dimensional dosimeter

被引:111
作者
Guo, P. Y. [1 ]
Adamovics, J. A.
Oldham, M.
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Rider Univ, Dept Biol & Chem, Lawrenceville, NJ 08648 USA
关键词
gel dosimetry; optical computed tomography; optical CT; 3D dosimetry; verification; PRESAGE (TM); radiochromic dosimeter;
D O I
10.1118/1.2192888
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The development of intensity-modulated radiotherapy (IMRT) has created a clear need for a dosimeter that can accurately and conveniently measure dose distributions in three dimensions to assure treatment quality. PRESAGE (TM) is a new three dimensional (3D) dosimetry material consisting of an optically clear polyurethane matrix, containing a leuco dye that exhibits a radiochromic response when exposed to ionizing radiation. A number of potential advantages accrue over other gel dosimeters, including insensitivity to oxygen, radiation induced light absorption contrast rather than scattering contrast, and a solid texture amenable to machining to a variety of shapes and sizes without the requirement of an external container. In this paper, we introduce an efficient method to investigate the basic properties of a 3D dosimetry material that exhibits an optical dose response. The method is applied here to study the key aspects of the optical dose response of PRESAGE (TM): linearity, dose rate dependency, reproducibility, stability, spectral changes in absorption, and temperature effects. PRESAGE (TM) was prepared in 1 X 1 X 4.5 cm(3) optical cuvettes for convenience and was irradiated by both photon and electron beams to different doses, dose rates, and energies. Longer PRESAGE (TM) columns (2 X 2 X 13 cm(3)) were formed without an external container, for measurements of photon and high energy electron depth-dose curves. A linear optical scanning technique was used to detect the depth distribution of radiation induced optical density (OD) change along the PRESAGE (TM) columns and cuvettes. Measured depth-OD curves were compared with percent depth dose (PDD). Results indicate that PRESAGE (TM) has a linear optical response to radiation dose (with a root mean square error of similar to 1%), little dependency on dose rate (similar to 2%), high intrabatch reproducibility (< 2%), and can be stable (similar to 2%) during 2 hours to 2 days post irradiation. Accurate PRESAGE (TM) dosimetry requires temperature control within 1 degrees C. Variations in the PRESAGE (TM) formulation yield corresponding variations in sensitivity, stability, and density. CT numbers in the range 100-470 were observed. In conclusion, the small volume studies presented here indicate PRESAGE (TM) to be a promising, versatile, and practical new dosimetry material with applicability for radiation therapy. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1338 / 1345
页数:8
相关论文
共 28 条
  • [1] Adamovics J., 2004, Journal of Physics: Conference Series, V3, P172, DOI 10.1088/1742-6596/3/1/020
  • [2] Adamovics J, 2003, MED PHYS, V30, P1349
  • [3] ADAMOVICS J, Patent No. 20040211917
  • [4] Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element method
    Baldock C.
    Harris P.J.
    Piercy A.R.
    Healy B.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2001, 24 (1): : 19 - 30
  • [5] Polyvinyl alcohol-Fricke hydrogel and cryogel:: two new gel dosimetry systems with low Fe3+ diffusion
    Chu, KC
    Jordan, KJ
    Battista, JJ
    Van Dyk, J
    Rutt, BK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) : 955 - 969
  • [6] De Deene Y, 2000, PHYS MED BIOL, V45, P859, DOI 10.1088/0031-9155/45/4/304
  • [7] Doran S. J., 2004, Journal of Physics: Conference Series, V3, P240, DOI 10.1088/1742-6596/3/1/037
  • [8] FONG PM, 2001, MAGN RESON MED, V9, P901
  • [9] Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (II) modelling oxygen diffusion
    Hepworth, SJ
    Leach, MO
    Doran, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08) : 1875 - 1884
  • [10] Use of BANG® polymer gel for dose measurements in a 68 MeV proton beam
    Heufelder, J
    Stiefel, S
    Pfaender, M
    Lüdemann, L
    Grebe, G
    Heese, J
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1235 - 1240