Adaptive Kaczmarz method for image reconstruction in electrical impedance tomography

被引:13
|
作者
Li, Taoran [1 ]
Kao, Tzu-Jen [2 ]
Isaacson, David [3 ]
Newell, Jonathan C. [4 ]
Saulnier, Gary J. [1 ]
机构
[1] Rensselaer Polytech Inst, Dept Elect Engn, Troy, NY 12180 USA
[2] GE Global Res Ctr, Schenectady, NY 12309 USA
[3] Rensselaer Polytech Inst, Dept Math Sci, Troy, NY 12180 USA
[4] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
关键词
electrical impedance tomography; image reconstruction; optimal current pattern; ORDERED SUBSETS; ALGORITHMS;
D O I
10.1088/0967-3334/34/6/595
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present an adaptive Kaczmarz method for solving the inverse problem in electrical impedance tomography and determining the conductivity distribution inside an object from electrical measurements made on the surface. To best characterize an unknown conductivity distribution and avoid inverting the Jacobian-related term J(T) J which could be expensive in terms of computation cost and memory in large-scale problems, we propose solving the inverse problem by applying the optimal current patterns for distinguishing the actual conductivity from the conductivity estimate between each iteration of the block Kaczmarz algorithm. With a novel subset scheme, the memory-efficient reconstruction algorithm which appropriately combines the optimal current pattern generation with the Kaczmarz method can produce more accurate and stable solutions adaptively as compared to traditional Kaczmarz- and Gauss-Newton-type methods. Choices of initial current pattern estimates are discussed in this paper. Several reconstruction image metrics are used to quantitatively evaluate the performance of the simulation results.
引用
收藏
页码:595 / 608
页数:14
相关论文
共 50 条
  • [1] A new image reconstruction method for electrical impedance tomography
    Hou, WD
    Mo, WL
    BIOMEDICAL PHOTONICS AND OPTOELECTRONIC IMAGING, 2000, 4224 : 64 - 67
  • [2] Studies of an adaptive Kaczmarz method for electrical impedance imaging
    Li, Taoran
    Isaacson, David
    Newell, Jonathan C.
    Saulnier, Gary J.
    Journal of Physics: Conference Series, 2013, 434 (01)
  • [3] Studies of an Adaptive Kaczmarz Method for Electrical Impedance Imaging
    Li, Taoran
    Isaacson, David
    Newell, Jonathan C.
    Saulnier, Gary J.
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [4] New image reconstruction method in dynamic electrical impedance tomography
    Hou, WD
    Mo, WL
    ELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY III, 2002, 4925 : 1 - 4
  • [5] Adaptive techniques in electrical impedance tomography reconstruction
    Li, Taoran
    Isaacson, David
    Newell, Jonathan C.
    Saulnier, Gary J.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (06) : 1111 - 1124
  • [6] A Joint Image Reconstruction Method for Capacitively Coupled Electrical Impedance Tomography
    Wu, Yimin
    Jiang, Yandan
    Ji, Haifeng
    Wang, Baoliang
    Huang, Zhiyao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [7] Multimodal Image Reconstruction of Electrical Impedance Tomography Using Kernel Method
    Liu, Zhe
    Yang, Yunjie
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [8] Temporal image reconstruction in electrical impedance tomography
    Adler, Andy
    Dai, Tao
    Lionheart, William R. B.
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S1 - S11
  • [9] Image reconstruction using adaptive mesh refinement based on adaptive thresholding in electrical impedance tomography
    Kim, Bong Seok
    Kim, Kyung Youn
    Kim, Sin
    NUCLEAR ENGINEERING AND DESIGN, 2014, 270 : 421 - 426
  • [10] Boundary image reconstruction based on the nonmonotonic and self-adaptive trust region method for electrical impedance tomography
    Tan, Chunxiao
    Xu, Guizhi
    Li, Youyu
    Xu, Yaoyuan
    Su, Guozhong
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (08) : 951 - 962