Mid-term evaluation of the new Glaukos iStent with phacoemulsification in coexistent open-angle glaucoma or ocular hypertension and cataract

被引:64
作者
Arriola-Villalobos, Pedro [1 ]
Maria Martinez-de-la-Casa, Jose [2 ,3 ,4 ,5 ]
Diaz-Valle, David [2 ,3 ,4 ,5 ]
Garcia-Vidal, Sara E. [1 ]
Fernandez-Perez, Cristina [6 ]
Garcia-Sanchez, Julian [2 ,3 ,4 ,5 ,7 ]
Garcia-Feijoo, Julian [2 ,3 ,4 ,5 ,7 ]
机构
[1] Hosp Clin San Carlos, Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Serv Oftalmol, Madrid, Spain
[2] Univ Complutense Madrid, Serv Oftalmol, Dept Oftalmol, Madrid, Spain
[3] Univ Complutense Madrid, ORL, Fac Med, Madrid, Spain
[4] Hosp Clin San Carlos, Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Madrid, Spain
[5] Inst Salud Carlos III, Cooperat Res Network Age Related Ocular Pathol Vi, Madrid, Spain
[6] Hosp Clin San Carlos, Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Serv Med Prevent & Salud Publ, Madrid, Spain
[7] Univ Complutense Madrid, Inst Invest Oftalmol Ramon Castroviejo, Madrid, Spain
关键词
Glaucoma; Treatment Surgery; Aqueous humour; MICRO-BYPASS STENT; INTRAOCULAR-PRESSURE; LONG-TERM; SURGERY; IMPLANTATION; COMPLICATIONS;
D O I
10.1136/bjophthalmol-2012-302394
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To evaluate the mid-term efficacy and safety of the GTS-400-iStent combined with phacoemulsification in patients with cataract and open-angle glaucoma (OAG) or ocular hypertension (OHT). Methods Prospective, non-comparative, uncontrolled, interventional case series study. Subjects underwent phacoemulsification and two GTS-400 implantation. Efficacy outcomes: intraocular pressure (IOP) and antiglaucoma medications. Safety outcomes: complications, best-corrected visual acuity and endothelial cell count (ECC). Follow-up was 1 year. Results 20 patients were enrolled (mean age: 75.18.6 years). Mean medicated baseline IOP was 19.95 +/- 3.71 mm Hg and 26 +/- 3.11 mm Hg without medication. Mean final IOP was 16.75 +/- 2.24, determining a final IOP decrease of 35.68% (9.42 +/- 3 mm Hg; p<0.001), from baseline washout IOP. Mean number of medications fell from 1.3 +/- 0.66 to 0.3 +/- 0.57 (P<0.001). 75% of patients were off medications at one year. Mean ECC decreased from 2289.64 +/- 393.5 cells/mm(2) to 1986.95 +/- 520.58 cells/mm(2). Conclusions Combined cataract surgery with implantation of GTS-400-iStent seems to be an effective and safe procedure.
引用
收藏
页码:1250 / 1255
页数:6
相关论文
共 21 条
[1]   Postoperative infection in penetrating versus non-penetrating glaucoma surgery [J].
Ang, Ghee Soon ;
Varga, Zsolt ;
Shaarawy, Tarek .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (12) :1571-1576
[2]   Combined iStent trabecular micro-bypass stent implantation and phacoemulsification for coexistent open-angle glaucoma and cataract: a long-term study [J].
Arriola-Villalobos, Pedro ;
Maria Martinez-de-la-Casa, Jose ;
Diaz-Valle, David ;
Fernandez-Perez, Cristina ;
Garcia-Sanchez, Julian ;
Garcia-Feijoo, Julian .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (05) :645-649
[3]   Trabecular bypass stents decrease intraocular pressure in cultured human anterior segments [J].
Bahler, CK ;
Smedley, GT ;
Zhou, J ;
Johnson, DH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (06) :988-994
[4]   Ocular surface inflammatory changes induced by topical antiglaucoma drugs -: Human and animal studies [J].
Baudouin, C ;
Pisella, PJ ;
Fillacier, K ;
Goldschild, M ;
Becquet, F ;
De Saint Jean, M ;
Béchetoille, A .
OPHTHALMOLOGY, 1999, 106 (03) :556-563
[5]   Effect of cataract surgery on the corneal endothelium - Modern phacoemulsification compared with extracapsular cataract surgery [J].
Bourne, RRA ;
Minassian, DC ;
Dart, JKG ;
Rosen, P ;
Kaushal, S ;
Wingate, N .
OPHTHALMOLOGY, 2004, 111 (04) :679-685
[6]   ADVERSE-EFFECTS OF TOPICAL ANTIGLAUCOMA MEDICATION .2. THE OUTCOME OF FILTRATION SURGERY [J].
BROADWAY, DC ;
GRIERSON, I ;
OBRIEN, C ;
HITCHINGS, RA .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (11) :1446-1454
[7]   Endothelial cells analysis with the TOPCON specular microscope SP-2000P and IMAGEnet system [J].
Cheung, SW ;
Cho, P .
CURRENT EYE RESEARCH, 2000, 21 (04) :788-798
[8]   Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma Randomized double-masked clinical trial [J].
Fea, Antonio M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03) :407-412
[9]   Fluorophotometric Study of the Effect of the Glaukos Trabecular Microbypass Stent on Aqueous Humor Dynamics [J].
Fernandez-Barrientos, Yolanda ;
Garcia-Feijoo, Julian ;
Martinez-de-la-Casa, Jose M. ;
Pablo, Luis E. ;
Fernandez-Perez, Cristina ;
Garcia Sanchez, Julian .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) :3327-3332
[10]   Corneal complications of glaucoma surgery [J].
Hau, Scott ;
Barton, Keith .
CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (02) :131-136