Trifocality Achieved Through Polypseudophakia: Optical Quality and Light Loss Compared With a Single Trifocal Intraocular Lens

被引:23
作者
Labuz, Grzegorz [1 ]
Auffarth, Gerd U. [1 ]
Knorz, Michael C. [2 ]
Son, Hyeck-Soo [1 ]
Yildirim, Timur M. [1 ]
Khoramnia, Ramin [1 ]
机构
[1] Univ Hosp Heidelberg, Dept Ophthalmol, David J Apple Ctr Vis Res, Heidelberg, Germany
[2] Heidelberg Univ, Med Fac Mannheim, Mannheim, Germany
关键词
DEPTH-OF-FOCUS; EXTENDED DEPTH; IMAGE QUALITY; IMPLANTATION; BAG;
D O I
10.3928/1081597X-20200715-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the optical performance of a two-intraocular lens (IOL) system with that of a single capsular bag trifocal IOL. METHODS: The two-IOL configuration of a monofocal RayOne Aspheric (Rayner Intraocular Lenses, Ltd) and a Sulcoflex Trifocal (Rayner Intraocular Lenses, Ltd) lens was compared in vitro with a single-lens option (RayOne Trifocal; Rayner Intraocular Lenses, Ltd). Two samples of each IOL model were studied with an optical metrology device. The optical quality was assessed using the area under the modulation transfer function (MTF). The impact of the supplementary lens misalignment on the MTF was tested. The light loss was also measured using a power meter. RESULTS: The two-IOL system produced three well-defined focal peaks comparable to those of the single lens. The MTF area of the single- and two-IOL configuration was, respectively, 22.5 and 20.7 at far, 16.4 and 15.4 at intermediate, and 14.9 for each configuration at near. A moderate decentration (up to 0.6 mm) had a minimal effect at intermediate and near on the supplementary lens MTF and no impact at far. A 5 degrees tilt did not alter the MTF. The supplementary tens caused a 1.3% decrease in the optical power. CONCLUSIONS: The optical quality of the two-IOL system matched that of the single trifocal lens. A tow-power supplementary IOL demonstrated high tolerance to misalignment and minimal light attenuation. The reversibility of the two-IOL approach may prove advantageous clinically.
引用
收藏
页码:570 / 577
页数:8
相关论文
共 30 条
[1]   Optimizing the subjective depth-of-focus with combinations of fourth- and sixth-order spherical aberration [J].
Benard, Yohann ;
Lopez-Gil, Norberto ;
Legras, Richard .
VISION RESEARCH, 2011, 51 (23-24) :2471-2477
[2]  
Campbell FW, 1957, Optica Acta, V4, P157, DOI [10.1080/713826091, DOI 10.1080/713826091]
[3]   Primary sulcus implantation of a diffractive CrossMark multifocal pseudophakic piggyback intraocular lens [J].
Cassagne, Myriam ;
Porterie, Marie ;
Gauthier, Laurent ;
Chapotot, Eric ;
Soler, Vincent ;
Malecaze, Francois ;
Fournie, Pierre .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (03) :266-273
[4]   Secondary pigmentary glaucoma associated with piggyback intraocular lens implantation [J].
Chang, SHL ;
Lim, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10) :2219-2222
[5]   LUMINANCE DISCRIMINATION OF BRIEF FLASHES UNDER VARIOUS CONDITIONS OF ADAPTATION [J].
CORNSWEET, TN ;
PINSKER, HM .
JOURNAL OF PHYSIOLOGY-LONDON, 1965, 176 (02) :294-+
[6]   History and development of the apodized diffractive intraocular lens [J].
Davison, James A. ;
Simpson, Michael J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :849-858
[8]   Piggybacking intraocular implants to correct pseudophakic refractive error [J].
Gayton, JL ;
Sanders, V ;
Van Der Karr, M ;
Raanan, MG .
OPHTHALMOLOGY, 1999, 106 (01) :56-59
[9]   IMPLANTING 2 POSTERIOR CHAMBER INTRAOCULAR LENSES IN A CASE OF MICROPHTHALMOS [J].
GAYTON, JL ;
SANDERS, VN .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06) :776-777
[10]   Interlenticular opacification: Clinicopathological correlation of a complication of posterior chamber piggyback intraocular lenses [J].
Gayton, JL ;
Apple, DJ ;
Peng, Q ;
Visessook, N ;
Sanders, V ;
Werner, L ;
Pandey, SK ;
Escobar-Gomez, M ;
Hoddinott, DSM ;
Van Der Karr, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (03) :330-336