The kinetic and biological activity of different loaded rhBMP-2 calcium phosphate cement implants in rats

被引:69
作者
Bodde, Esther W. H. [1 ]
Boerman, Otto C. [2 ]
Russel, Frans G. M. [3 ]
Mikos, Antonios G. [4 ]
Spauwen, Paul H. M. [5 ]
Jansen, John A. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Periodontol & Biomat, NL-6525 ED Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Nucl Med, NL-6525 ED Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Pharmacol & Toxicol, NL-6525 ED Nijmegen, Netherlands
[4] Rice Univ, Dept Bioengn, Houston, TX USA
[5] Radboud Univ Nijmegen, Med Ctr, Dept Plast & Reconstruct Surg, NL-6525 ED Nijmegen, Netherlands
关键词
BMP; drug release; calcium phosphate cement; PLGA; bone regeneration;
D O I
10.1002/jbm.a.31830
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The healing of large bone defects can be improved by osteogenic bone graft substitutes, due to growth factor inclusion. A sustained release of these growth factors provides more efficient bioactivity when compared with burst release and might reduce the dose required for bone regeneration, which is desirable for socioeconomical and safety reasons. In this study, we compared different rhBMP-2 loadings in a sustained release system of CaP cement and PLGA-microparticles and were able to couple kinetic to biological activity data. Fifty-two rats received a critical-size cranial defect, which was left open or filled with the cement composites. The implants consisted of plain, high, and five-fold lower dose rhBMP-2 groups. Implantation time was 4 and 12 weeks. Longitudinal in vivo release was monitored by scintigraphic imaging of 131 I-labeled rhBMP-2. Quantitative analysis of the scintigraphic images revealed a sustained release of I-131-rhBMP-2 for both doses, with different release profiles between the two loadings. However, around 70% of the initial dose was retained in both implant formulations. Although low amounts of rhBMP-2 were released (2.4 +/- 0.8 mu g in 5 weeks), histology showed defect bridging in the high-dose implants. Release out of the low-dose implants was not sufficient to enhance bone formation. Implant degradation was limited in all formulations, but was mainly seen in the high-dose group. Low amounts of sustained released rhBMP-2 were sufficient to bridge critically sized defects. A substantial amount of rhBMP-2 was retained in the implants because of the slow release rate and the limited degradation. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res 87A: 780-791, 2008
引用
收藏
页码:780 / 791
页数:12
相关论文
共 46 条
[1]  
[Anonymous], [No title captured]
[2]   Osteogenesis with coral is increased by BMP and BMC in a rat cranioplasty [J].
Arnaud, E ;
De Pollak, C ;
Meunier, A ;
Sedel, L ;
Damien, C ;
Petite, H .
BIOMATERIALS, 1999, 20 (20) :1909-1918
[3]   Lower dose of rhBMP-2 achieves spine fusion when combined with an osteoconductive bulking agent in non-human primates [J].
Barnes, B ;
Boden, SD ;
Louis-Ugbo, J ;
Tomak, PR ;
Park, JS ;
Park, MS ;
Minamide, A .
SPINE, 2005, 30 (10) :1127-1133
[4]   THE HALF-LIFE OF IODINE-131 [J].
BURKINSHAW, L .
PHYSICS IN MEDICINE AND BIOLOGY, 1958, 2 (03) :255-257
[5]   Bone morphogenetic proteins [J].
Chen, D ;
Zhao, M ;
Mundy, GR .
GROWTH FACTORS, 2004, 22 (04) :233-241
[6]   Segmental bone regeneration using a load-bearing biodegradable carrier of bone morphogenetic protein-2 [J].
Chu, Tien-Min G. ;
Warden, Stuart J. ;
Turner, Charles H. ;
Stewart, Rena L. .
BIOMATERIALS, 2007, 28 (03) :459-467
[7]  
Cleek RL, 1997, J BIOMED MATER RES, V35, P525, DOI 10.1002/(SICI)1097-4636(19970615)35:4<525::AID-JBM12>3.0.CO
[8]  
2-A
[9]   In vivo bone response to porous calcium phosphate cement [J].
del Real, RP ;
Ooms, E ;
Wolke, JGC ;
Vallet-Regí, M ;
Jansen, JA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 65A (01) :30-36
[10]   Mechanism for the action of bone morphogenetic proteins and regulation of their activity [J].
Ebara, S ;
Nakayama, K .
SPINE, 2002, 27 (16) :S10-S15