Low-power readout electronics for microchannel plate detectors with cross strip anodes

被引:1
|
作者
Pfeifer, M. [1 ]
Barnstedt, J. [1 ]
Bauer, C. [2 ]
Diebold, S. [1 ]
Hermanutz, S. [1 ]
Kalkuhl, C. [1 ]
Kappelmann, N. [1 ]
Loechner, S. [2 ]
Schanz, T. [1 ]
Schmelling, M. [2 ]
Werner, K. [1 ]
机构
[1] Inst Astron & Astrophys IAAT, Sand 1, D-72076 Tubingen, Germany
[2] Univ Tubingen, Kepler Ctr Astro & Particle Phys, D-72076 Tubingen, Germany
来源
SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY | 2012年 / 8443卷
关键词
Ultraviolet; Observatory; WSO-UV; Future missions; Microchannel plate; Cross strip anode; Beetle chip;
D O I
10.1117/12.925137
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The World Space Observatory - Ultraviolet (WSO-UV) will be the only space telescope for the ultraviolet wavelength range between 102 and 310 nm during the next decade. It is a multinational project under Russian leadership with contributions from Ukraine and Spain. Its main instrument, the WSO-UV Spectrographs (WUVS), was designed by IAAT in collaboration with the Leibniz Institut fur Analytische Wissenschaften, Berlin. We are developing the corresponding microchannel plate detectors using new combinations of materials for the photocathode as well as a 64 by 64 cross strip anode for event position determination. Charge pre-amplification is performed by the Beetle chip designed at the ASIC laboratory of the MPIK for LHCb at CERN. It has 128 pre-amplifiers on one die and provides the analog output in a four-fold serial stream. This stream is digitized by four ADCs and processed in a Microsemi RTAX FPGA. Processed data are sent to the instrument control unit via a SpaceWire interface. This concept results in one order of magnitude reduced power consumption in comparison to the use of conventional pre-amplifiers as well as a reduced volume, weight and complexity of the readout electronics. This paper presents the architecture of the electronics and details of the FPGA design as well as an estimation of the performance of our setup.
引用
收藏
页数:6
相关论文
共 15 条
  • [1] Characterisation of low power readout electronics for a UV microchannel plate detector with cross-strip readout
    Pfeifer, M.
    Barnstedt, J.
    Diebold, S.
    Hermanutz, S.
    Kalkuhl, C.
    Kappelmann, N.
    Schanz, T.
    Schuetze, B.
    Werner, K.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [2] Cross strip anodes for microchannel plate imaging detectors
    Siegmund, OHW
    Zaninovich, J
    Tremsin, A
    Hull, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 397 - 406
  • [3] Cross-strip anodes for microchannel plate detectors
    Siegmund, OHW
    Tremsin, AS
    Abiad, R
    Vallerga, JV
    UV/EUV AND VISIBLE SPACE INSTRUMENTATION FOR ASTRONOMY AND SOLAR PHYSICS, 2001, 4498 : 131 - 140
  • [4] FIRE - A fast image readout and electronics for microchannel plate detectors
    Lapington, JS
    Rees, K
    INSTRUMENTATION FOR UV/EUV ASTRONOMY AND SOLAR MISSIONS, 2000, 4139 : 51 - 58
  • [5] Performance of the wedge-and-strip microchannel plate detectors and electronics for the Global Ultraviolet Imager
    Goldsten, JO
    Humm, DC
    Paxton, LJ
    Ogorzalek, BS
    Gary, SA
    Hayes, JR
    Boldt, JD
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 408 - 416
  • [6] Microchannel plate cross-strip detectors with high spatial and temporal resolution
    Siegmund, O.
    Tremsin, A.
    Vallerga, J.
    McPhate, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01) : 118 - 122
  • [7] Development of Sealed Cross Strip Readout UV Detectors
    Siegmund, O. H. W.
    Curtis, T.
    McPhate, J. B.
    Darling, N.
    Cremer, T.
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XXII, 2021, 11821
  • [8] A comparison of readout techniques for high-resolution imaging with microchannel plate detectors
    Lapington, JS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2) : 361 - 365
  • [9] High resolution cross strip anodes for photon counting detectors
    Siegmund, OHW
    Tremsin, AS
    Vallerga, JV
    Abiad, R
    Hull, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3) : 177 - 181
  • [10] The Capacitive Division Image Readout: A Novel Imaging Device for Microchannel Plate Detectors
    Lapington, J. S.
    Conneely, T. M.
    Leach, S. A.
    Moore, L.
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XVIII, 2013, 8859