Comparison of Macular Ganglion Cell Complex Thickness by Fourier-Domain OCT in Normal Tension Glaucoma and Primary Open-Angle Glaucoma

被引:53
作者
Kim, Na Rae [1 ,2 ]
Hong, Samin [1 ]
Kim, Ji Hyun [1 ]
Rho, Seung Soo [1 ]
Seong, Gong Je [1 ]
Kim, Chan Yun [1 ]
机构
[1] Yonsei Univ, Dept Ophthalmol, Inst Vis Res, Coll Med, Seoul 120752, South Korea
[2] Inha Univ, Dept Ophthalmol, Sch Med, Inchon, South Korea
基金
新加坡国家研究基金会;
关键词
Fourier-domain OCT; ganglion cell complex; normal tension glaucoma; primary open-angle glaucoma; VISUAL-FIELD DAMAGE; NERVE-FIBER LAYER; BALTIMORE EYE SURVEY; INTRAOCULAR-PRESSURE; DEFECTS; HEAD; ASSOCIATION; PROGRESSION; PREVALENCE; JAPANESE;
D O I
10.1097/IJG.0b013e3182254cde
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare perimacular ganglion cell complex (GCC) parameters between patients with normal tension glaucoma (NTG) and primary open-angle glaucoma (POAG). Methods: Participants, consecutively enrolled from January 2009 to June 2009, underwent optical coherence tomographic imaging with RTVue-100 (Optovue Inc, Fremont, CA). Optic nerve head (ONH) parameters, retinal nerve fiber layer (RNFL) parameters, and GCC parameters were acquired. Mean measurements of ONH, RNFL, and GCC parameters among the normal, NTG, and POAG groups were compared using analysis of variance. Area under the receiver operator characteristic curve was used to assess the ability of each parameter to detect glaucomatous changes. Results: Fifty-eight normal controls, 51 patients with NTG, and 52 patients with POAG were included. Mean measurements of ONH parameters were similar between the NTG and POAG groups (all P > 0.05). Average RNFL thickness did not differ between the NTG and POAG groups (P = 0.053), whereas average GCC thickness significantly differed between the NTG and POAG groups (P = 0.001). In terms of pattern-based parameters of GCC, focal loss volume did not differ between the NTG and POAG groups (P = 0.165), whereas global loss volume was significantly higher in the POAG group (P < 0.001). There were no statistically significant differences between RNFL and GCC measurements with respect to the ability to detect glaucomatous changes. Conclusions: GCC loss in the NTG group was more localized compared with diffuse GCC loss in the POAG group. Perimacular GCC parameters could be a good alternative or supplement to peripapillary RNFL measurements for diagnosis and research in patients with NTG.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 35 条
[1]  
ARAIE M, 1993, OPHTHALMOLOGY, V100, P1808
[2]   Clinical utility of Intraocular pressure monitoring outside of normal office hours in patients with glaucoma [J].
Barkana, Yaniv ;
Anis, Sarah ;
Liebmann, Jeffrey ;
Tello, Celso ;
Ritch, Robert .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) :793-797
[3]   PATTERNS OF EARLY VISUAL-FIELD LOSS IN OPEN-ANGLE GLAUCOMA [J].
CAPRIOLI, J ;
SEARS, M ;
MILLER, JM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 103 (04) :512-517
[4]   COMPARISON OF VISUAL-FIELD DEFECTS IN THE LOW-TENSION GLAUCOMAS WITH THOSE IN THE HIGH-TENSION GLAUCOMAS [J].
CAPRIOLI, J ;
SPAETH, GL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 97 (06) :730-737
[5]  
CAPRIOLI J, 1985, ARCH OPHTHALMOL-CHIC, V103, P1145
[6]   VISUAL-FIELD DAMAGE IN NORMAL-TENSION AND HIGH-TENSION GLAUCOMA [J].
CHAUHAN, BC ;
DRANCE, SM ;
DOUGLAS, GR ;
JOHNSON, CA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (06) :636-642
[7]   LOW-TENSION GLAUCOMA [J].
CHUMBLEY, LC ;
BRUBAKER, RF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1976, 81 (06) :761-767
[8]   DIFFUSE VISUAL-FIELD LOSS IN CHRONIC OPEN-ANGLE AND LOW-TENSION GLAUCOMA [J].
DRANCE, SM ;
DOUGLAS, GR ;
AIRAKSINEN, PJ ;
SCHULZER, M ;
HITCHINGS, RA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 104 (06) :577-580
[9]   OPTIC DISK TOPOGRAPHY IN PATIENTS WITH LOW-TENSION AND PRIMARY OPEN ANGLE GLAUCOMA [J].
FAZIO, P ;
KRUPIN, T ;
FEITL, ME ;
WERNER, EB ;
CARRE, DA .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (05) :705-708
[10]   VISUAL-FIELD CHANGE IN LOW-TENSION GLAUCOMA OVER A 5-YEAR FOLLOW-UP [J].
GLIKLICH, RE ;
STEINMANN, WC ;
SPAETH, GL .
OPHTHALMOLOGY, 1989, 96 (03) :316-320