Virtual Averaging Making Nonframe-Averaged Optical Coherence Tomography Images Comparable to Frame-Averaged Images

被引:9
作者
Chen, Chieh-Li [1 ,2 ]
Ishikawa, Hiroshi [1 ,2 ]
Wollstein, Gadi [1 ,2 ]
Bilonick, Richard A. [1 ,3 ]
Kagemann, Larry [1 ,2 ]
Schuman, Joel S. [1 ,2 ,4 ]
机构
[1] Univ Pittsburgh, Dept Ophthalmol, Sch Med, Ophthalmol & Visual Sci Res Ctr,UPMC Eye Ctr,Eye, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Swanson Sch Engn, Dept Bioengn, Pittsburgh, PA USA
[3] Univ Pittsburgh, Dept Biostat, Grad Sch Publ Hlth, Pittsburgh, PA 15261 USA
[4] Univ Pittsburgh, Sch Med, McGowan Inst Regenerat Sci, Pittsburgh, PA USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2016年 / 5卷 / 01期
基金
美国国家卫生研究院;
关键词
image processing; optical coherence tomography; retina; FIBER LAYER THICKNESS; SPECKLE NOISE-REDUCTION; SPECTRAL-DOMAIN; SIGNAL NORMALIZATION; TIME-DOMAIN; NERVE; INSTRUMENTS; OCT; DEVICES; EYES;
D O I
10.1167/tvst.5.1.1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Methods: Twenty-one eyes of 21 healthy volunteers were scanned with noneyetracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. Results: All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-tonoise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t-test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 mu m, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 mu m, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. Conclusion: The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Translational Relevance: Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frameaveraged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects.
引用
收藏
页数:14
相关论文
共 37 条
  • [1] Speckle reduction in optical coherence tomography images by use of a spatially adaptive wavelet filter
    Adler, DC
    Ko, TH
    Fujimoto, JG
    [J]. OPTICS LETTERS, 2004, 29 (24) : 2878 - 2880
  • [2] [Anonymous], 2012, R LANG ENV STAT COMP
  • [3] Baumal C R, 1999, Curr Opin Ophthalmol, V10, P182, DOI 10.1097/00055735-199906000-00006
  • [4] Bilonick R., 2003, merror: Accuracy and Precision of Measurements
  • [5] OpenMx: An Open Source Extended Structural Equation Modeling Framework
    Boker, Steven
    Neale, Michael
    Maes, Hermine
    Wilde, Michael
    Spiegel, Michael
    Brick, Timothy
    Spies, Jeffrey
    Estabrook, Ryne
    Kenny, Sarah
    Bates, Timothy
    Mehta, Paras
    Fox, John
    [J]. PSYCHOMETRIKA, 2011, 76 (02) : 306 - 317
  • [6] Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    Bourne, RRA
    Medeiros, FA
    Bowd, C
    Jahanbakhsh, K
    Zangwill, LM
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1280 - 1285
  • [7] Comparison of Retinal Nerve Fiber Layer Thickness Measurement Bias and Imprecision across Three Spectral-Domain Optical Coherence Tomography Devices
    Buchser, Nancy M.
    Wollstein, Gadi
    Ishikawa, Hiroshi
    Bilonick, Richard A.
    Ling, Yun
    Folio, Lindsey S.
    Kagemann, Larry
    Noecker, Robert J.
    Albeiruti, Eiyass
    Schuman, Joel S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 3742 - 3747
  • [8] Signal Normalization Reduces Systematic Measurement Differences Between Spectral-Domain Optical Coherence Tomography Devices
    Chen, Chieh-Li
    Ishikawa, Hiroshi
    Ling, Yun
    Wollstein, Gadi
    Bilonick, Richard A.
    Xu, Juan
    Fujimoto, James G.
    Sigal, Ian A.
    Kagemann, Larry
    Schuman, Joel S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (12) : 7317 - 7322
  • [9] Individual A-Scan Signal Normalization Between Two Spectral Domain Optical Coherence Tomography Devices
    Chen, Chieh-Li
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Ling, Yun
    Bilonick, Richard A.
    Kagemann, Larry
    Sigal, Ian A.
    Schuman, Joel S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3463 - 3471
  • [10] Wavelet Denoising during Optical Coherence Tomography of the Prostate Nerves using the Complex Wavelet Transform
    Chitchian, Shahab
    Fiddy, Michael
    Fried, Nathaniel M.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3016 - 3019