A New Inexpensive Simulation Model for Ultrasound Assessment of Optic Nerve Sheath Diameter

被引:2
作者
Johnson, Garrett G. R. J. [1 ]
Jelic, Tomislav [2 ]
Derksen, Angela [3 ]
Unger, Bertram [4 ]
Zeiler, Frederick [5 ,6 ]
Ziesmann, Markus [1 ]
Gillman, Lawrence M. [1 ]
机构
[1] Univ Manitoba, Dept Surg, GF439,820 Sherbrook St, Winnipeg, MB R3A 1R9, Canada
[2] Univ Manitoba, Dept Emergency Med, Winnipeg, MB, Canada
[3] Seven Oaks Gen Hosp, Emergency Dept, Winnipeg, MB, Canada
[4] Univ Manitoba, Dept Internal Med, Winnipeg, MB, Canada
[5] Univ Manitoba, Dept Surg, Sect Neurosurg, Winnipeg, MB, Canada
[6] Univ Cambridge, Dept Med, Div Anaesthesia, Cambridge, England
关键词
Handheld ultrasound; Intracranial pressure; Optic nerve sheath diameter; Point-of-care ultrasound; Ultrasound; RAISED INTRACRANIAL-PRESSURE; UNIQUE MODEL; LOW-COST; ULTRASONOGRAPHY; SONOGRAPHY; PHANTOM;
D O I
10.1017/cjn.2020.37
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Sonographic measurement of optic nerve sheath diameter (ONSD) is becoming increasingly accepted as a diagnostic modality to detect elevations in intracranial pressure. As this technique becomes more widespread, methods to address the inherent operator-dependent nature of this modality will need to be developed. We propose a novel low-cost model to accurately simulate sonographic ONSD measurement for purposes of training and assessment. Methods: We designed models composed of medical tubing of various diameters readily available from typical hospital supplies and suspended them in gelatin. The models were evaluated by ultrasound by three expert point-of-care sonographers using a standard linear array probe and technique proposed in the literature. Results: This model generates faithful simulation of the ONS that closely approximatesin vivoimages and can be used to produce accurate, reproducible measurements. Materials are low cost and easy to acquire and assemble. Conclusions: Our model provides realistic simulated images of the ONS. Through comparison of sonographic measurements to the known tube diameters, this model serves as a promising inexpensive tool to teach the method of ultrasound assessment of ONSD or as a way to determine accuracy of this novel ultrasound technology.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 32 条
[1]  
[Anonymous], 2016, Treatment manual., VPP, P1
[2]  
[Anonymous], 2016, LUM ULTR SYST US MAN
[3]  
[Anonymous], 2019, BUTT IQ PERS ULTR SY
[4]  
[Anonymous], 2018, SON IVIZ US MAN
[5]   Mortality and long-term functional outcome associated with intracranial pressure after traumatic brain injury [J].
Badri, Shide ;
Chen, Jasper ;
Barber, Jason ;
Temkin, Nancy R. ;
Dikmen, Sureyya S. ;
Chesnut, Randall M. ;
Deem, Steven ;
Yanez, N. David ;
Treggiari, Miriam M. .
INTENSIVE CARE MEDICINE, 2012, 38 (11) :1800-1809
[6]   Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging [J].
Baeuerle, Jochen ;
Schuchardt, Florian ;
Schroeder, Laure ;
Egger, Karl ;
Weigel, Matthias ;
Harloff, Andreas .
BMC NEUROLOGY, 2013, 13
[7]   Intra- and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy Adults [J].
Baeuerle, Jochen ;
Lochner, Piergiorgio ;
Kaps, Manfred ;
Nedelmann, Max .
JOURNAL OF NEUROIMAGING, 2012, 22 (01) :42-45
[8]  
Ballantyne S A, 2002, Eur J Ultrasound, V15, P145, DOI 10.1016/S0929-8266(02)00036-8
[9]  
Blaivas M, 2003, ACAD EMERG MED, V10, P376, DOI 10.1197/aemj.10.4.376
[10]   AN EASILY MADE, LOW-COST, TISSUE-LIKE ULTRASOUND PHANTOM MATERIAL [J].
BUDE, RO ;
ADLER, RS .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (04) :271-273