Iminodiacetic acid-containing polymer brushes grafted onto silica gel for preconcentration and determination of copper(II) in environmental samples

被引:14
|
作者
Panahi, Homayon Ahmad [1 ]
Mehmandost, Nasrin [1 ]
Moniri, Elham [2 ]
Galaev, Igor Yu [3 ]
机构
[1] Islamic Azad Univ, Dept Chem, Cent Tehran Branch, Tehran, Iran
[2] Islamic Azad Univ, Dept Chem, Varamin Pishva Branch, Tehran, Iran
[3] DSM Food Specialties BV, Delft, Netherlands
关键词
solid-phase extraction; polymer grafting; copper; isotherm study; preconcentration; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; WATER SAMPLES; HEAVY-METALS; TRACE-ELEMENTS; SEDIMENT SAMPLES; COPRECIPITATION; CADMIUM; RESIN; SEPARATION;
D O I
10.1002/app.36802
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Silica gel has been modified by silylation with 3-mercaptopropyltrimethoxysilane followed by graft polymerization of dimethylacrylamide and (N,N-bis-carboxymethyl)amino-3-allylglycerol-co-dimethylacrylamide, synthesized via the reaction of allyl glycidyl ether with iminodiacetic acid. The sorbent, poly(AGE/IDA-co-DMAA)-grafted silica gel, has been characterized by FTIR, elemental analysis, thermogravimetric analysis (TGA), FT-Raman, and scanning electron microscopy and studied for the preconcentration and determination of trace amounts of Cu(II) ion in environmental water samples. The optimum pH value for quantitative sorption of Cu(II) in batch mode was 5.5 and desorption was achieved, using 0.5 mol L-1 nitric acid. The sorption capacity of functionalized sorbent is 32.3 mg g-1. The chelating sorbent was reused for 15 sorptiondesorption cycles without any significant change in sorption capacity. The profile of copper uptake by the sorbent reflected good accessibility of the chelating sites in the poly(AGE/IDA-co-DMAA)-grafted silica gel. Scatchard analysis demonstrated homogeneous nature of binding sites. The equilibrium adsorption data of Cu(II) on modified sorbent were analyzed by Langmuir, Freundlich, Temkin, and RedlichPeterson models. Based on equilibrium adsorption data, the Langmuir, Freundlich, and Temkin constants were determined as 0.0665, 4.26, and 8.34, respectively, at pH 5.5 and 20 degrees C. Adsorption isotherms were analyzed at different temperatures to obtain free energy, enthalpy, and entropy of adsorption. The method was applied for Cu(II) determination in sea water samples. (C) 2012 Wiley Periodicals, Inc. J Appl Polym Sci, 2012
引用
收藏
页码:480 / 489
页数:10
相关论文
共 50 条
  • [1] Functionalised polymer brushes grafted onto nanosiliceous support for removal of cadmium (II) in environmental and biological samples
    Ghoroghi, Atefeh
    Panahi, Homayon Ahmad
    Arjmandpour, Saba
    Moniri, Elham
    MICRO & NANO LETTERS, 2019, 14 (11) : 1169 - 1174
  • [2] Application of Grafted Silica Gel for Improvement of FAAS Conditions of Copper(II) Determination in Water Samples
    Tobiasz, Anna
    Walas, Stanislaw
    Buda, Marta
    Laszczyk, Katarzyna
    Trzewik, Bartosz
    Mrowiec, Halina
    CURRENT ANALYTICAL CHEMISTRY, 2014, 10 (02) : 288 - 295
  • [3] Determination of neodymium (III) in human plasma and environmental samples with poly(allyl glycidyl ether/iminodiacetic acid- co-dimethylacrylamide) brushes grafted onto siliceous support
    Sadeghi, Hayedeh Bagheri
    Panahi, Homayon Ahmad
    Ghasemi, Maryam
    Moniri, Elham
    Galaev, Igor Yu
    ADVANCES IN POLYMER TECHNOLOGY, 2012, 31 (04) : 257 - 270
  • [4] β-Cyclodextrin/thermosensitive containing polymer brushes grafted onto magnetite nano-particles for extraction and determination of venlafaxine in biological and pharmaceutical samples
    Panahi, Homayon Ahmad
    Alaei, Haniyeh Sadat
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 476 (1-2) : 178 - 184
  • [5] 7-Amino-4-azaheptyl Grafted onto a Silica Gel as a Sorbent for the On-line Preconcentration and Determination of Iron(III) in Water Samples
    Sandra V. M. de Moraes
    Mateus M. Tisott
    Caroline D. Milcharek
    Jorge L. Brasil
    Tania M. H. Costa
    Márcia R. Gallas
    Edilson V. Benvenutti
    Eder C. Lima
    Analytical Sciences, 2005, 21 : 573 - 577
  • [6] 7-amino-4-azaheptyl grafted onto a silica gel as a sorbent for the on-line preconcentration and determination of iron(III) in water samples
    de Moraes, SVM
    Tisott, MM
    Milcharek, CD
    Brasil, JL
    Costa, TMH
    Gallas, MR
    Benvenutti, EV
    Lima, EC
    ANALYTICAL SCIENCES, 2005, 21 (05) : 573 - 577
  • [7] 7-Amino-4-azaheptyl grafted onto a silica gel as a sorbent for the on-line preconcentration and determination of iron(III) in water samples
    Colégio Militar de Porto Alegre, Av. Jose Bonifacio, 363, 90040-130, Porto Alegre, RS, Brazil
    不详
    1600, 573-577 (May 2005):
  • [8] Preconcentration, separation and determination of trace Hg(II) in environmental samples with aminopropylbenzoylazo-2-mercaptobenzothiazole bonded to silica gel
    Ma, WX
    Liu, F
    Li, KA
    Chen, M
    Tong, SY
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 191 - 196
  • [9] Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography
    Sadeghi, Hayedeh Bagheri
    Panahi, Homayon Ahmad
    Mahabadi, Mahsa
    Moniri, Elham
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 14 (03): : 765 - 773
  • [10] Poly[1-(N,N-bis-carboxymethyl)amino-3-allylglycerol-co-dimethylacrylamide] brushes grafted onto siliceous support for preconcentration and determination of cobalt (II) in human plasma and environmental samples
    Homayon Ahmad Panahi
    Mahshid Nikpour Nezhati
    Rohollah Abedini Kashkoieh
    Elham Moniri
    Igor Yu. Galaev
    Korean Journal of Chemical Engineering, 2013, 30 : 1722 - 1728