Tracking Changes in Cardiac Output: Statistical Considerations on the 4-Quadrant Plot and the Polar Plot Methodology

被引:119
作者
Saugel, Bernd [1 ]
Grothe, Oliver [2 ,3 ]
Wagner, Julia Y. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
[2] Univ Cologne, Dept Econ & Social Stat, D-50931 Cologne, Germany
[3] Karlsruhe Inst Technol, Inst Operat Res, D-76021 Karlsruhe, Germany
关键词
PULSE-CONTOUR ANALYSIS; PULMONARY-ARTERY THERMODILUTION; LITHIUM DILUTION; AGREEMENT; SURGERY; PRECISION; BIOIMPEDANCE; METAANALYSIS; ALGORITHM; MONITORS;
D O I
10.1213/ANE.0000000000000725
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
When comparing 2 technologies for measuring hemodynamic parameters with regard to their ability to track changes, 2 graphical tools are omnipresent in the literature: the 4-quadrant plot and the polar plot recently proposed by Critchley et al. The polar plot is thought to be the more advanced statistical tool, but care should be taken when it comes to its interpretation. The polar plot excludes possibly important measurements from the data. The polar plot transforms the data nonlinearily, which may prevent it from being seen clearly. In this article, we compare the 4-quadrant and the polar plot in detail and thoroughly describe advantages and limitations of each. We also discuss pitfalls concerning the methods to prepare the researcher for the sound use of both methods. Finally, we briefly revisit the Bland-Altman plot for the use in this context.
引用
收藏
页码:514 / 524
页数:11
相关论文
共 47 条
[21]   Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: Comparison with thermodilution method [J].
Gujjar A.R. ;
Muralidhar K. ;
Banakal S. ;
Gupta R. ;
Sathyaprabha T.N. ;
Jairaj P.S. .
Journal of Clinical Monitoring and Computing, 2008, 22 (03) :175-180
[22]   THE IMPORTANCE OF USING THE CORRECT BOUNDS ON THE BLAND-ALTMAN LIMITS OF AGREEMENT WHEN MULTIPLE MEASUREMENTS ARE RECORDED PER PATIENT [J].
Hamilton, Cody ;
Lewis, Steven .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2010, 24 (03) :173-175
[23]   Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period [J].
Hamzaoui, Olfa ;
Monnet, Xavier ;
Richard, Christian ;
Osman, David ;
Chemla, Denis ;
Teboul, Jean-Louis .
CRITICAL CARE MEDICINE, 2008, 36 (02) :434-440
[24]   Analysis of Variance of Communication Latencies in Anesthesia: Comparing Means of Multiple Log-Normal Distributions [J].
Ledolter, Johannes ;
Dexter, Franklin ;
Epstein, Richard H. .
ANESTHESIA AND ANALGESIA, 2011, 113 (04) :888-896
[25]   Analysis of Interventions Influencing or Reducing Patient Waiting While Stratifying by Surgical Procedure [J].
Ledolter, Johannes ;
Dexter, Franklin .
ANESTHESIA AND ANALGESIA, 2011, 112 (04) :950-957
[26]   Lithium dilution cardiac output measurement: A comparison with thermodilution [J].
Linton, R ;
Band, D ;
OBrien, T ;
Jonas, M ;
Leach, R .
CRITICAL CARE MEDICINE, 1997, 25 (11) :1796-1800
[27]   A NEW METHOD OF MEASURING CARDIAC-OUTPUT IN MAN USING LITHIUM DILUTION [J].
LINTON, RAF ;
BAND, DM ;
HAIRE, KM .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (02) :262-266
[28]   Noninvasive Cardiac Output Monitors: A State-of the-Art Review [J].
Marik, Paul E. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (01) :121-134
[29]   Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock [J].
Marx, G ;
Schuerholz, T ;
Sümpelmann, R ;
Simon, T ;
Leuwer, M .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2005, 22 (02) :129-134
[30]   Using the Bland-Altman method to measure agreement with repeated measures [J].
Myles, P. S. ;
Cui, J. .