Do directional deep brain stimulation leads rotate after implantation?

被引:10
|
作者
Krueger, Marie T. [1 ,2 ]
Naseri, Yashar [1 ,3 ]
Cavalloni, Fabian [1 ]
Reinacher, Peter C. [2 ,4 ]
Kagi, Georg [5 ]
Weber, Johannes [6 ]
Brogle, Deborah [1 ,5 ]
Bozinov, Oliver [1 ]
Hagele-Link, Stefan [5 ]
Brugger, Florian [5 ]
机构
[1] Cantonal Hosp St Gallen, Dept Neurosurg, Rorschacher Str 95,Haus 04, CH-9007 St Gallen, Switzerland
[2] Univ Freiburg, Dept Stereotact & Funct Neurosurg, Fac Med, Med Ctr, Freiburg, Germany
[3] Univ Freiburg, Dept Neurosurg, Fac Med, Med Ctr, Freiburg, Germany
[4] Fraunhofer Inst Laser Technol, Aachen, Germany
[5] Cantonal Hosp St Gallen, Dept Neurol, St Gallen, Switzerland
[6] Cantonal Hosp St Gallen, Dept Radiol, St Gallen, Switzerland
关键词
Deep brain stimulation; Directional leads; Iron sights; Rotational fluoroscopy;
D O I
10.1007/s00701-020-04568-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The two middle contacts of directional leads (d-leads) for deep brain stimulation are split into three segments, allowing current steering toward desired axial directions. To facilitate programming, their final orientation needs to be reliably determined. However, it is currently unclear whether d-leads rotate after implantation. Our objective was to assess the degree of d-lead rotation after implantation. Methods We retrospectively analyzed d-lead orientation on intraoperative X-rays, postoperative CT scans (latencies to surgery: 108-189 min postoperatively), and rotational fluoroscopies (4-9 days postoperatively) for a consecutive series of 32 implanted d-leads. For five d-leads, a CT scan with a mean follow-up of 57 days (range 28-182) was available. All d-leads were implanted with the marker facing anterior and the intention to hit an "iron sight" (ISi) on the X-ray, indicating anterior orientation (i.e., 0 degrees +/- 6 degrees). Results In nine d-leads, an ISi was visible on the final X-ray; median orientation was 1.5 degrees (range 0.5-6.0 degrees) at the first follow-up CT, confirming anterior orientation. In d-leads without ISi or where ISi was not evaluable, the median rotation was 15.5 degrees (9.5-35.0 degrees) and 26.5 degrees (5.5-62.0 degrees), respectively. The orientation of the initial CT was comparable with the orientation determined by the postoperative rotational fluoroscopy and second CT in all d-lead groups. Conclusion D-lead orientation does not change within the first week after implantation. We provide first indications that d-lead orientation remains stable for several weeks after surgery. Determination of lead orientation using marker-based X-ray alone seems too imprecise; adding the ISi method can increase determination of intraoperative orientation.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 50 条
  • [1] Do directional deep brain stimulation leads rotate after implantation?
    Marie T. Krüger
    Yashar Naseri
    Fabian Cavalloni
    Peter C. Reinacher
    Georg Kägi
    Johannes Weber
    Deborah Brogle
    Oliver Bozinov
    Stefan Hägele-Link
    Florian Brugger
    Acta Neurochirurgica, 2021, 163 : 197 - 203
  • [2] Longitudinal Assessment of Rotation Angles after Implantation of Directional Deep Brain Stimulation Leads
    Lange, Florian
    Steigerwald, Frank
    Engel, Doortje
    Malzacher, Tobias
    Neun, Tilmann
    Fricke, Patrick
    Volkmann, Jens
    Matthies, Cordula
    Capetian, Philipp
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2021, 99 (02) : 150 - 158
  • [3] Deep brain stimulation electrodes may rotate after implantation—an animal study
    Alexander Rau
    H. Urbach
    V. A. Coenen
    K. Egger
    P. C. Reinacher
    Neurosurgical Review, 2021, 44 : 2349 - 2353
  • [4] Deep brain stimulation electrodes may rotate after implantation-an animal study
    Rau, Alexander
    Urbach, H.
    Coenen, V. A.
    Egger, K.
    Reinacher, P. C.
    NEUROSURGICAL REVIEW, 2021, 44 (04) : 2349 - 2353
  • [5] Directional Leads for Deep Brain Stimulation: Opportunities and Challenges
    Schupbach, W. M. Michael
    Chabardes, Stephan
    Matthies, Cordula
    Pollo, Claudio
    Steigerwald, Frank
    Timmermann, Lars
    Vandewalle, Veerle Visser
    Volkmann, Jens
    Schuurman, P. Richard
    MOVEMENT DISORDERS, 2017, 32 (10) : 1371 - 1375
  • [6] First experience with 59 directional leads in Deep Brain Stimulation
    Nickl, R.
    Fricke, P.
    Steigerwald, F.
    Volkmann, J.
    Matthies, C.
    MOVEMENT DISORDERS, 2017, 32
  • [7] Directional Leads for Deep Brain Stimulation: Technical Notes and Experiences
    Fricke, Patrick
    Nickl, Robert
    Breun, Maria
    Volkmann, Jens
    Kirsch, Dalal
    Ernestus, R. -I.
    Steigerwald, Frank
    Matthies, Cordula
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2021, 99 (04) : 305 - 312
  • [8] Review of directional leads, stimulation patterns and programming strategies for deep brain stimulation
    Zhou, Yijie
    Song, Yibo
    Song, Xizi
    He, Feng
    Xu, Minpeng
    Ming, Dong
    COGNITIVE NEURODYNAMICS, 2025, 19 (01)
  • [9] Directional Deep Brain Stimulation Lead Implantation: A Single Center Experience
    Kochanski, R.
    Borghei, A.
    Pal, G.
    Metman, L. Verhagen
    Lynn, F.
    Karl, J.
    Sani, S.
    MOVEMENT DISORDERS, 2019, 34 : S866 - S866
  • [10] Directional leads in deep brain stimulation - surgical handling and evolving therapy options
    Matthies, C.
    Fricke, P.
    Nickl, R.
    Capetian, P.
    Steigerwald, F.
    Volkmann, J.
    MOVEMENT DISORDERS, 2019, 34 : S871 - S872