Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis

被引:41
作者
Fukuda, Shinichi [1 ,2 ]
Beheregaray, Simone [1 ]
Hoshi, Sujin [1 ]
Yamanari, Masahiro [2 ,3 ]
Lim, Yiheng [2 ,3 ]
Hiraoka, Takahiro [1 ]
Yasuno, Yoshiaki [2 ,3 ]
Oshika, Tetsuro [1 ,2 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058575, Japan
[2] Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki, Japan
[3] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058575, Japan
关键词
forme fruste keratoconus; three dimensional anterior segment optical coherence tomography; rotating scheimpflug camera with placido topography system; receiver operating characteristic curve; CORNEAL TOPOGRAPHY; ANTERIOR; PENTACAM; VIDEOKERATOGRAPHY; REPEATABILITY; PARAMETERS; PACHYMETRY;
D O I
10.1136/bjophthalmol-2013-303477
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective To evaluate the ability of parameters measured by three-dimensional (3D) corneal and anterior segment optical coherence tomography (CAS-OCT) and a rotating Scheimpflug camera combined with a Placido topography system (Scheimpflug camera with topography) to discriminate between normal eyes and forme fruste keratoconus. Methods Forty-eight eyes of 48 patients with keratoconus, 25 eyes of 25 patients with forme fruste keratoconus and 128 eyes of 128 normal subjects were evaluated. Anterior and posterior keratometric parameters (steep K, flat K, average K), elevation, topographic parameters, regular and irregular astigmatism (spherical, asymmetry, regular and higher-order astigmatism) and five pachymetric parameters (minimum, minimum-median, inferior-superior, inferotemporal-superonasal, vertical thinnest location of the cornea) were measured using 3D CAS-OCT and a Scheimpflug camera with topography. The area under the receiver operating curve (AUROC) was calculated to assess the discrimination ability. Compatibility and repeatability of both devices were evaluated. Results Posterior surface elevation showed higher AUROC values in discrimination analysis of forme fruste keratoconus using both devices. Both instruments showed significant linear correlations (p<0.05, Pearson's correlation coefficient) and good repeatability (ICCs: 0.885-0.999) for normal and forme fruste keratoconus. Conclusions Posterior elevation was the best discrimination parameter for forme fruste keratoconus. Both instruments presented good correlation and repeatability for this condition.
引用
收藏
页码:1554 / 1559
页数:6
相关论文
共 29 条
[1]  
AMSLER M, 1961, Wien Klin Wochenschr, V73, P842
[2]   Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus [J].
de Sanctis, Ugo ;
Loiacono, Carlotta ;
Richiardi, Lorenzo ;
Turco, Davide ;
Mutani, Bernardo ;
Grignolo, Federico M. .
OPHTHALMOLOGY, 2008, 115 (09) :1534-1539
[3]   Reproductivity and repeatability of central corneal thickness measurement in keratoconus using the rotating scheimpflug camera and ultrasound pachymetry [J].
De Sanctis, Ugo ;
Missolungi, Alessandro ;
Mutani, Bernardo ;
Richiardi, Lorenzo ;
Grignolo, Federico M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) :712-718
[4]   Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system [J].
Emre, Sinan ;
Doganay, Selim ;
Yologlu, Saim .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10) :1708-1712
[5]   Anterior Ocular Biometry Using 3-Dimensional Optical Coherence Tomography [J].
Fukuda, Shinichi ;
Kawana, Keisuke ;
Yasuno, Yoshiaki ;
Oshika, Tetsuro .
OPHTHALMOLOGY, 2009, 116 (05) :882-889
[6]   Corneal Elevation Topography: Best Fit Sphere, Elevation Distance, Asphericity, Toricity, and Clinical Implications [J].
Gatinel, Damien ;
Malet, Jacques ;
Thanh Hoang-Xuan ;
Azar, Dimitri T. .
CORNEA, 2011, 30 (05) :508-515
[7]  
KLYCE SD, 1984, INVEST OPHTH VIS SCI, V25, P1426
[8]   Chasing the suspect: keratoconus [J].
Klyce, Stephen D. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (07) :845-847
[9]   The role of reference body selection in calculating posterior corneal elevation and prediction of keratoconus using rotating Scheimpflug camera [J].
Kovacs, Illes ;
Mihaltz, Kata ;
Ecsedy, Monika ;
Nemeth, Janos ;
Nagy, Zoltan Z. .
ACTA OPHTHALMOLOGICA, 2011, 89 (03) :e251-e256
[10]   Keratoconus Diagnosis with Optical Coherence Tomography Pachymetry Mapping [J].
Li, Yan ;
Meisler, David M. ;
Tang, Maolong ;
Lu, Ake T. H. ;
Thakrar, Vishakha ;
Reiser, Bibiana J. ;
Huang, David .
OPHTHALMOLOGY, 2008, 115 (12) :2159-2166