Effects of tracking landmarks and tibial point of resistive force application on the assessment of patellar tendon mechanical properties in vivo

被引:7
作者
Mersmann, Falk [1 ,2 ]
Seynnes, Olivier R. [3 ]
Legerlotz, Kirsten [1 ,2 ]
Arampatzis, Adamantios [1 ,2 ]
机构
[1] Humboldt Univ, Dept Training & Movement Sci, Unter Linden 6, D-10099 Berlin, Germany
[2] Berlin Sch Movement Sci, Berlin, Germany
[3] Norwegian Sch Sports Sci, Dept Phys Performance, Oslo, Norway
关键词
Tendon elongation; Ultrasound; Dynamometry; Pad position; Tracking features; MORPHOLOGICAL PROPERTIES; BIOCHEMICAL-PROPERTIES; ACHILLES-TENDON; MUSCLE; MOMENT; CONTRACTIONS; HYPERTROPHY; ADAPTATION; STIFFNESS; BEHAVIOR;
D O I
10.1016/j.jbiomech.2018.02.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The different methods used to assess patellar tendon elongation in vivo may partly explain the large variation of mechanical properties reported in the literature. The present study investigated the effects of tracking landmark position and tibial point of resistive force application during leg extensions in a dynamometer. Nineteen adults performed isometric contractions with a proximal and distal dynamometer shank pad position. Knee joint moments were calculated employing an inverse dynamics approach. Tendon elongation was measured using the patellar apex and either the tibial tuberosity (T) or plateau (P) as tracking landmark. Using P for tracking introduced a bias towards greater values of tendon elongation at all force levels from 100 N to maximum tendon force (TFmax; p < 0.05). The differences between landmarks considering maximum tendon strain were greater at the proximal shank pad position (p < 0.05). Tendon stiffness was lower for P compared with T, but only in intervals up to 50% of TFmax (p < 0.05). The agreement between T and P for stiffness calculated between 50% and TFmax was acceptable with the distal, but poor with the proximal pad position. We demonstrated that using the tibia plateau and not the insertion as tracking landmark clearly affects the assessment of the force-elongation curve of the patellar tendon. However, using a distal point of resistive force application and calculating tendon stiffness between 50% and TFmax seems to yield an acceptable agreement between landmarks. These findings have important implications for the assessment of tendon properties in vivo and cross-study comparisons. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 50 条
  • [1] MECHANICAL BEHAVIOUR OF TENDON IN VITRO - A PRELIMINARY REPORT
    ABRAHAMS, M
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (05): : 433 - +
  • [2] Differences between measured and resultant joint moments during voluntary and artificially elicited isometric knee extension contractions
    Arampatzis, A
    Karamanidis, K
    De Monte, G
    Stafilidis, S
    Morey-Klapsing, G
    Brüggemann, GP
    [J]. CLINICAL BIOMECHANICS, 2004, 19 (03) : 277 - 283
  • [3] Adaptational responses of the human Achilles tendon by modulation of the applied cyclic strain magnitude
    Arampatzis, Adamantios
    Karamanidis, Kiros
    Albracht, Kirsten
    [J]. JOURNAL OF EXPERIMENTAL BIOLOGY, 2007, 210 (15) : 2743 - 2753
  • [4] Influence of the muscle-tendon unit's mechanical and morphological properties on running economy
    Arampatzis, Adamantios
    De Monte, Gianpiero
    Karamanidis, Kiros
    Morey-Klapsing, Gaspar
    Stafilidis, Savvas
    Brueggemann, Gert-Peter
    [J]. JOURNAL OF EXPERIMENTAL BIOLOGY, 2006, 209 (17) : 3345 - 3357
  • [5] Tendinopathy alters mechanical and material properties of the Achilles tendon
    Arya, Shruti
    Kulig, Kornelia
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (03) : 670 - 675
  • [6] BENEDICT J V, 1968, Journal of Biomechanics, V1, P53, DOI 10.1016/0021-9290(68)90038-9
  • [7] Biewener AA, 1998, J EXP BIOL, V201, P1681
  • [8] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [9] Muscle performance during maximal isometric and dynamic contractions is influenced by the stiffness of the tendinous structures
    Bojsen-Moller, J
    Magnusson, SP
    Rasmussen, LR
    Kjaer, M
    Aagaard, P
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (03) : 986 - 994
  • [10] Butler D L, 1978, Exerc Sport Sci Rev, V6, P125