Simultaneous detection of guanine and adenine in DNA and meat samples using graphitized mesoporous carbon modified electrode

被引:60
作者
Thangaraj, Rajendiran [1 ]
Kumar, Annamalai Senthil [1 ]
机构
[1] Vellore Inst Technol Univ, Environm & Analyt Chem Div, Sch Adv Sci, Vellore 632014, Tamil Nadu, India
关键词
Graphitized mesoporous carbon; Simultaneous detection; Guanine; Adenine; DNA; ELECTROCHEMICAL DETERMINATION; CAPILLARY-ELECTROPHORESIS; NANOTUBES; PURINE; FILM; NANOPARTICLES; OXIDATION; GRAPHENE; BEHAVIOR; TYROSINE;
D O I
10.1007/s10008-012-1895-0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A graphitized mesoporous carbon modified glassy carbon electrode (GCE/GMC) prepared by drop coating method without any pre-anodization of the underlying GCE or external binder/matrix, has been demonstrated for simultaneous electrochemical oxidation of guanine (G) and adenine (A) at oxidation potentials 0.60 and 0.85 V vs. Ag/AgCl, respectively, in the presence of thymine (T) by differential pulse voltammetric method in pH 7 phosphate buffer solution. Control voltammetric experiments with unmodified GCE, graphite nanopowder and multiwalled carbon nanotube modified electrodes yielded either feeble or with high-background current responses. Interestingly, the GCE/GMC showed highly efficient, stable and well-defined voltammetric signals. Thymine oxidation signal noticed discretely at 1.15 V vs. Ag/AgCl on the GCE/GMC was not influenced for the simultaneous determination of G and A. Constructed DPV calibration graphs were linear in the range of 25-200 and 25-150 mu M, respectively, for the G and A. Corresponding detection limit (S/N = 3) values are 0.76 and 0.63 mu M. Real sample analyses for the detection of G and A concentrations in calf-thymus DNA (detected [G]/[A] ratio = 0.82), beef brain and beef liver were successfully demonstrated with recovery values 100 %.
引用
收藏
页码:583 / 590
页数:8
相关论文
共 50 条
  • [41] A sensitive porphyrin/reduced graphene oxide electrode for simultaneous detection of guanine and adenine
    Yalin Chen
    Tao Mei
    Yi Chen
    Jianying Wang
    Jinhua Li
    Yang Fu
    Guangchao Dai
    Sheng Wang
    Weilai Xiong
    Xianbao Wang
    [J]. Journal of Solid State Electrochemistry, 2016, 20 : 2055 - 2062
  • [42] Fabrication of Cu-CeO2 Coated Multiwall Carbon Nanotube Composite Electrode for Simultaneous Determination of Guanine and Adenine
    Akturk, Merve
    Karabiberoglu, Sukriye Ulubay
    Dursun, Zekerya
    [J]. ELECTROANALYSIS, 2018, 30 (02) : 238 - 249
  • [43] Simultaneous determination of guanine, adenine and thymine using a modified carbon paste electrode by TiO2 nanoparticles-magnesium(II) doped natrolite zeolite
    Arvand, M.
    Mazhabi, R. Motaghed
    Niazi, A.
    [J]. ELECTROCHIMICA ACTA, 2013, 89 : 669 - 679
  • [44] Electrocatalytic oxidation and the simultaneous determination of guanine and adenine on (2,6-pyridinedicarboxylic acid)/graphene composite film modified electrode
    Li, Chunxiang
    Qiu, Xiyang
    Ling, Yulin
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 704 : 44 - 49
  • [46] Fabrication of poly (2,6-pyridinedicarboxylic acid)/MWNTs modified electrode for simultaneous determination of guanine and adenine in DNA
    Deng, Ke Qin
    Li, Chun Xiang
    Ling, Yu Lin
    Xu, Guo Rong
    Li, Xiao Fang
    [J]. CHINESE CHEMICAL LETTERS, 2011, 22 (08) : 981 - 984
  • [47] Voltammetric sensing of guanine and adenine using a glassy carbon electrode modified with a tetraoxocalix[2]arene[2]triazine Langmuir-Blodgett film
    Zou, Lina
    Li, Yamin
    Ye, Baoxian
    [J]. MICROCHIMICA ACTA, 2011, 173 (3-4) : 285 - 291
  • [48] Fabrication of copper oxide nanoparticles modified carbon paste electrode and its application in simultaneous electroanalysis of guanine, adenine and thymine
    Siddegowda, K. S.
    Mahesh, B.
    Swamy, Kumara N.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2018, 280 : 277 - 286
  • [49] Electrocatalytic performance of a zinc sulphide nanoparticles-modified carbon paste electrode for the simultaneous determination of acetaminophen, guanine and adenine
    Mahanthappa, Mallappa
    Kottam, Nagaraju
    Yellappa, Shivaraj
    [J]. ANALYTICAL METHODS, 2018, 10 (11) : 1362 - 1371
  • [50] Selective voltammetric and flow-injection determination of guanine and adenine on a glassy carbon electrode modified by a ruthenium hexachloroplatinate film
    Shaidarova, L. G.
    Gedmina, A. V.
    Zhaldak, E. R.
    Chelnokova, I. A.
    Budnikov, G. K.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (08) : 741 - 749