Development of a Stable Isotope Dilution LC-MS/MS Method for the Alternaria Toxins Tentoxin, Dihydrotentoxin, and Isotentoxin

被引:26
|
作者
Liu, Yang [1 ]
Rychlik, Michael [1 ,2 ]
机构
[1] Tech Univ Munich, Chair Analyt Food Chem, D-85354 Freising Weihenstephan, Germany
[2] Tech Univ Munich, ZIEL Res Ctr Nutr & Food Sci, BIOANALYT Weihenstephan, D-85354 Freising Weihenstephan, Germany
关键词
tentoxin; dihydrotentoxin; isotentoxin; Alternaria; mycotoxin; stable isotope dilution assay; LC-MS/MS; synthesis; MICROWAVE; ASSAYS;
D O I
10.1021/jf305111w
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
For the Alternaria toxins tentoxin, dihydrotentoxin, and isotentoxin, a stable isotope dilution LC-MS/MS method was first developed. Triply deuterated internal standards were prepared via total synthesis and introducing the labels in the last step before cyclization. Method validation was carried out by using potato starch, tomato puree, and white pepper powder as blank matrices. For the three toxins the limits of detection ranged from 0.10 to 0.99 mu g/kg. The inter-/intraday relative standard deviations of the method were below 8.8%, and the recoveries ranged between 98 and 115%. Although cyclic peptides are known to show only negligible fragmentation, a low limit of detection was achieved with the optimization of mass spectrometry parameters and cleanup on C18-phenyl SPE columns providing a more selective binding of these phenyl-containing cyclic peptides. The method was applied to 103 food samples including bread, cereals, chips, juice, nuts, oil, sauce, seeds, and spices. Of these, 85% were contaminated with tentoxin and 55% were contaminated with dihydrotentoxin, whereas isotentoxin was not quantifiable. Maximal concentrations of tentoxin and dihydrotentoxin were 52.4 and 36.3 mu g/kg, respectively, and were both detected in paprika powder.
引用
收藏
页码:2970 / 2978
页数:9
相关论文
共 50 条
  • [1] Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer
    Habler, Katharina
    Gotthardt, Marina
    Schueler, Jan
    Rychlik, Michael
    FOOD CHEMISTRY, 2017, 218 : 447 - 454
  • [2] Development and validation of stable isotope dilution LC-MS/MS method for simultaneous quantification of four Alternaria toxins in 15 food commodities
    Zhang, Jia
    Huang, Renzhi
    Feng, Yongwei
    Yang, Ting
    Sun, Maozhong
    Kuang, Hua
    Xu, Chuanlai
    Guo, Lingling
    FOOD CHEMISTRY, 2024, 457
  • [3] Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in cereals
    Katharina Habler
    Michael Rychlik
    Analytical and Bioanalytical Chemistry, 2016, 408 : 307 - 317
  • [4] Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in cereals
    Habler, Katharina
    Rychlik, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (01) : 307 - 317
  • [5] Use of isotope-labeled Aflatoxins for LC-MS/MS stable isotope dilution analysis of foods
    Cervino, Christian
    Asam, Stefan
    Knopp, Dietmar
    Rychlik, Michael
    Niessner, Reinhard
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (06) : 1873 - 1879
  • [6] Development of a LC-MS/MS method using stable isotope dilution for the quantification of individual B6 vitamers in fruits, vegetables, and cereals
    Thomas Bachmann
    Andrea Maurer
    Michael Rychlik
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7237 - 7252
  • [7] Improved Stable Isotope Dilution Assay for Dietary Folates Using LC-MS/MS and Its Application to Strawberries
    Striegel, Lisa
    Chebib, Soraya
    Netzel, Michael E.
    Rychlik, Michael
    FRONTIERS IN CHEMISTRY, 2018, 6
  • [8] Rapid Method for the Determination of Multiple Mycotoxins in Wines and Beers by LC-MS/MS Using a Stable Isotope Dilution Assay
    Al-Taher, Fadwa
    Banaszewski, Katie
    Jackson, Lauren
    Zweigenbaum, Jerry
    Ryu, Dojin
    Cappozzo, Jack
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (10) : 2378 - 2384
  • [9] Development of a LC-MS/MS method using stable isotope dilution for the quantification of individual B6vitamers in fruits, vegetables, and cereals
    Bachmann, Thomas
    Maurer, Andrea
    Rychlik, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (26) : 7237 - 7252
  • [10] Development and Validation of a LC-ESI-MS/MS Method for the Determination of Alternaria Toxins Alternariol, Alternariol Methyl-Ether and Tentoxin in Tomato and Tomato-Based Products
    Rodriguez-Carrasco, Yelko
    Manes, Jordi
    Berrada, Houda
    Juan, Cristina
    TOXINS, 2016, 8 (11)