Percutaneous implantation of the Edwards SAPIEN™ pulmonic valve: initial results in the first 22 patients

被引:68
作者
Haas, Nikolaus A. [1 ]
Moysich, Axel [1 ]
Neudorf, Ulrich [2 ]
Mortezaeian, Hojjat [3 ]
Abdel-Wahab, Mohamed [4 ]
Schneider, Heike [5 ]
De Wolf, Daniel [6 ]
Petit, Jerome [7 ]
Narayanswami, Sreeram [8 ]
Laser, Kai Thorsten [1 ]
Sandica, Eugen [1 ]
机构
[1] Heart & Diabet Ctr NRW, Ctr Congenital Heart Defects, D-32545 Bad Oeynhausen, Germany
[2] Univ Essen Gesamthsch, Dept Pediat Cardiol, D-45147 Essen, Germany
[3] Rajaie Heart Ctr, Dept Pediat Cardiol, Tehran, Iran
[4] Segeberger Kliniken, Herzzentrum, Dept Cardiol, D-23795 Bad Segeberg, Germany
[5] Univ Gottingen, Dept Pediat Cardiol & Intens Care, D-37075 Gottingen, Germany
[6] Univ Ghent, Dept Pediat Cardiol, Ghent, Belgium
[7] Hop Marie Lannelongue, F-92350 Le Plessis Robinson, France
[8] Univ Cologne, Dept Pediat Cardiol, D-50937 Cologne, Germany
关键词
Percutaneous pulmonary valve implantation (PPVI); Edwards SAPIEN (TM) pulmonic valve; Congenital heart disease; Pulmonary stenosis; Pulmonary regurgitation; TRANSCATHETER HEART-VALVE; CONDUIT;
D O I
10.1007/s00392-012-0503-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Percutaneous pulmonary valve implantation (PPVI) was introduced in 2000 as an interventional procedure for the treatment of right ventricular outflow tract (RVOT) dysfunction. The new Edwards SAPIEN((TM)) pulmonic valve has reached CE certification at the end of 2010 thus offering an attractive alternative with extended sizes (23 and 26 mm) to the conventional Melody(A (R)) valve (sizes 18, 20 and 22 mm). Over a 1-year period, PPVI using the Edwards SAPIEN((TM)) pulmonic valve was performed in 22 patients using a standardized procedure. Primary diagnosis was tetralogy of Fallot (n = 11), pulmonary atresia (n = 2), Truncus arteriosus (n = 3), TGA/PS-Rastelli (n = 1), Ross surgery (n = 2), double outlet right ventricle (n = 2) and absent pulmonary valve syndrome (n = 1). The character of the RVOT for PPVI was transannular patch (n = 4), bioprosthesis (n = 2), homograft (n = 5) and Contegra(A (R)) conduit (n = 11). The leading hemodynamic problem consisted of a pulmonary stenosis (PS) (n = 2), pulmonary regurgitation (PR) (n = 11) and a combined PS/PR lesion (n = 9). In 21/22 patients, PPVI was performed successfully (10 x 23 and 11 x 26 mm). There were 9 female and 13 male patients; the mean age was 21.7 years (range 6-83 years), the mean length was 162 cm (range 111-181 cm) and the weight 56.5 kg (range 20-91 kg). Invasive data showed a decrease of RV-systolic pressure from 61.2 mmHg (+/- 23.1) to 41.2 mmHg (+/- 8.6) and reduction of RV-PA gradient from 37.3 mmHg (+/- 23.2) to 6.9 mmHg (+/- 5.3). The PA-systolic pressure increased from 25.8 mmHg (+/- 8.6) to 33.9 mmHg (+/- 9.3) as did the PA diastolic pressure (from 6.0 mmHg (+/- 5.6) to 14.6 mmHg (+/- 4.3). There was a substantial reduction of pulmonary regurgitation from before (none/trivial n = 0, mild n = 2, mode rate n = 9, severe n = 11) to after PPVI (none/trivial n = 20, mild n = 1). During the short-term follow-up of 5.7 months there was no change in the immediate results. PPVI using the Edwards SAPIEN((TM)) pulmonic valve can be performed safely in a wide range of patients with various diagnoses and underlying pathology of the RVOT and enables the restoration of an adult-size RVOT diameter. Although the immediate and short-term results seem promising, the long-term effects and safety have to be assessed in further clinical follow-up studies.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 23 条
  • [1] Percutaneous pulmonary valve implantation within bioprosthetic valves
    Asoh, Kentaro
    Walsh, Mark
    Hickey, Edward
    Nagiub, Mohamed
    Chaturvedi, Rajiv
    Lee, Kyong-Jin
    Benson, Lee N.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (11) : 1404 - 1409
  • [2] Edwards SAPIEN transcatheter heart valve in native pulmonary valve position
    Bertels, R. A.
    Blom, N. A.
    Schalij, M. J.
    [J]. HEART, 2010, 96 (09) : 661 - 661
  • [3] Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction
    Bonhoeffer, P
    Boudjemline, Y
    Saliba, Z
    Merckx, J
    Aggoun, Y
    Bonnet, D
    Acar, P
    Le Bidois, J
    Sidi, D
    Kachaner, J
    [J]. LANCET, 2000, 356 (9239) : 1403 - 1405
  • [4] Transcatheter Pulmonary Valve Implantation Using the Edwards SAPIEN™ Transcatheter Heart Valve
    Boone, Robert H.
    Webb, John G.
    Horlick, Eric
    Benson, Lee
    Cao, Qi-Ling
    Nadeem, N.
    Kiess, Maria
    Hijazi, Ziyad M.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (02) : 286 - 294
  • [5] Bailout Perventricular Pulmonary Valve Implantation Following Failed Percutaneous Attempt Using The Edwards Sapien Transcatheter Heart Valve
    Cubeddu, Roberto J.
    Hijazi, Ziyad M.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (02) : 276 - 280
  • [6] Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients
    Eicken, Andreas
    Ewert, Peter
    Hager, Alfred
    Peters, Bjoern
    Fratz, Sohrab
    Kuehne, Titus
    Busch, Raymonde
    Hess, John
    Berger, Felix
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 (10) : 1260 - 1265
  • [7] First implantation of the CE-marked transcatheter Sapien pulmonic valve in Europe
    Ewert, Peter
    Horlick, Eric
    Berger, Felix
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (01) : 85 - 87
  • [8] Martins JDF, 2010, REV PORT CARDIOL, V29, P1839
  • [9] Fiszer R, 2011, KARDIOL POL, V69, P749
  • [10] Percutaneous replacement of pulmonary valve using the Edwards-Cribier percutaneous heart valve: First report in a human patient
    Garay, F
    Webb, J
    Hijazi, ZM