Fatigue strength: effect of welding type and joint design executed in Ti-6Al-4V structures

被引:6
作者
Nunez Pantoja, Juliana M. C. [1 ]
Farina, Ana P. [1 ]
Vaz, Luis G. [2 ]
Consani, Rafael L. X. [1 ]
de Arruda Nobilo, Mauro A. [1 ]
Mesquita, Marcelo F. [1 ]
机构
[1] Univ Estadual Campinas, Dept Prosthodont & Periodontol, Piracicaba Dent Sch, Sao Paulo, Brazil
[2] State Univ Sao Paulo Julio de Mesquita Filho, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
titanium alloys; fatigue Performance; laser-weld Joint; TIG Welding; dental implant prostheses; COMMERCIALLY PURE TITANIUM; MECHANICAL-PROPERTIES; CORROSION-FATIGUE; WELDED TITANIUM; LASER; ALLOYS; ENVIRONMENTS; DEPTH; LIFE;
D O I
10.1111/j.1741-2358.2011.00598.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Fatigue strength: effect of welding type and joint design executed in Ti-6Al-4V structures Background: This study evaluated the fatigue strength of Ti-6Al-4V-machined structures submitted to laser (L)-welding and TIG (TIG)-welding procedures, varying the joint designs. Materials and methods: Seventy dumbbell rods were machined in Ti-6Al-4V alloy with central diameters of 3.5 mm. The specimens were sectioned and welded using TIG or L and three joint designs {'I' design, varying welding distances [0.0 mm (I00) or 0.6 mm (I06)], or 'X' [X] design}. The combinations of variables created six groups, which, when added to the intact group, made a total of seven groups (n = 10). L was executed as follows: 360 V/8 ms (X) and 390 V/9 ms (I00 and I06), with focus and frequency regulated to zero. TIG was executed using 2: 2 (X) and 3: 2 (I00 and I06) as welding parameters. Joints were finished, polished and submitted to radiographic examination to be analysed visually for the presence of porosity. The specimens were then subjected to mechanical cyclic tests, and the number of cycles completed until failure was recorded. The fracture surface was examined using a scanning electron microscope. Results: The Kruskal-Wallis and Dunn test (alpha = 0.05) indicated that the number of cycles resisted for fracture was higher to X for both welding procedures. To L, I06 was as resistant as X. The Mann-Whitney U-test (alpha = 0.05) indicated that L joints were more resistant than TIG to I00 and I06. Spearman's correlation coefficient (alpha = 0.05) indicated a negative correlation between the number of cycles and presence of porosity. Conclusion: Thus, to weld Ti-6Al-4V structures, the best condition is X, independent of the welding method employed.
引用
收藏
页码:E1005 / E1010
页数:6
相关论文
共 50 条
  • [41] Friction welding of conventional Ti-6Al-4V alloy with a Ti-6Al-4V based metal matrix composite reinforced by TiC
    Prikhodko, Sergey, V
    Savvakin, Dmytro G.
    Markovsky, Pavlo E.
    Stasuk, Olexander O.
    Penney, James
    Enzinger, Norbert
    Gaskill, Michael
    Deley, Frank
    WELDING IN THE WORLD, 2021, 65 (03) : 415 - 428
  • [42] Ti-6Al-4V Fatigue Strength After Shot Peening: The Role of a Corrosive Environment
    Sonntag, Robert
    Reinders, Joern
    Gibmeier, Jens
    Jaeger, Sebastian
    Kretzer, J. Philippe
    FATIGUE AND FRACTURE OF MEDICAL METALLIC MATERIALS AND DEVICES: 3RD VOLUME, 2014, 1559 : 98 - 108
  • [43] Effect of TiN/Ti coating combined with laser shock peening pre-treatment on the fatigue strength of Ti-6Al-4V titanium alloy
    Cao, Xin
    He, Weifeng
    Liao, Bin
    He, Guangyu
    Jiao, Yang
    Huang, Da
    Wang, Shiguang
    SURFACE & COATINGS TECHNOLOGY, 2020, 403
  • [44] Deformation and strength of Ti-6Al-4V alloyed with B at cryogenic temperatures
    Singh, Gaurav
    Bajargan, Govind
    Datta, Ranjan
    Ramamurty, Upadrasta
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2014, 611 : 45 - 57
  • [45] Experimental investigation of pug cutter embedded TIG welding of Ti-6Al-4V titanium alloy
    Gope, Deepak Kumar
    Kumar, Uday
    Chattopadhyaya, Somnath
    Mandal, Sanjoy
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (06) : 2715 - 2721
  • [46] Genesis of Microstructures in Friction Stir Welding of Ti-6Al-4V
    Jacques Tchein, Gnofam
    Jacquin, Dimitri
    Coupard, Dominique
    Lacoste, Eric
    Girot Mata, Franck
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2018, 49A (06): : 2113 - 2123
  • [47] Zirconia to Ti-6Al-4V braze joint for implantable biomedical device
    Jiang, GQ
    Mishler, D
    Davis, R
    Mobley, JP
    Schulman, JH
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 316 - 321
  • [48] A literature review of Ti-6Al-4V linear friction welding
    McAndrew, Anthony R.
    Colegrove, Paul A.
    Buhr, Clement
    Flipo, Bertrand C. D.
    Vairis, Achilleas
    PROGRESS IN MATERIALS SCIENCE, 2018, 92 : 225 - 257
  • [49] Effect of the Ultrasonic Surface Rolling Process on the Fretting Fatigue Behavior of Ti-6Al-4V Alloy
    Liu, Chengsong
    Liu, Daoxin
    Zhang, Xiaohua
    Yu, Shouming
    Zhao, Weidong
    MATERIALS, 2017, 10 (07): : 833
  • [50] Linear friction welding of Ti-6Al-4V: Modelling and validation
    Turner, R.
    Gebelin, J. -C.
    Ward, R. M.
    Reed, R. C.
    ACTA MATERIALIA, 2011, 59 (10) : 3792 - 3803