A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

被引:4
作者
Baensch, Dietmar [1 ]
Schneider, Ralph [1 ]
Akin, Ibrahim [1 ]
Nienaber, Cristoph A. [1 ]
机构
[1] Univ Hosp Rostock, Heart Ctr Rostock, Rostock, Germany
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2012年 / 60期
关键词
Medicine; Issue; 60; Implantable defibrillator; dual chamber; single chamber; tachycardia detection;
D O I
10.3791/3750
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Implantable cardioverter-defibrillators (ICDs) terminate ventricular tachycardia (VT) and ventricular fibrillation (VF) with high efficacy and can protect patients from sudden cardiac death (SCD). However, inappropriate shocks may occur if tachycardias are misdiagnosed. Inappropriate shocks are harmful and impair patient quality of life. The risk of inappropriate therapy increases with lower detection rates programmed in the ICD. Single-chamber detection poses greater risks for misdiagnosis when compared with dual-chamber devices that have the benefit of additional atrial information. However, using a dual-chamber device merely for the sake of detection is generally not accepted, since the risks associated with the second electrode may outweigh the benefits of detection. Therefore, BIOTRONIK developed a ventricular lead called the Linox(SMART) S DX, which allows for the detection of atrial signals from two electrodes positioned at the atrial part of the ventricular electrode. This device contains two ring electrodes; one that contacts the atrial wall at the junction of the superior vena cava (SVC) and one positioned at the free floating part of the electrode in the atrium. The excellent signal quality can only be achieved by a special filter setting in the ICD (Lumax 540 and 740 VR-T DX, BIOTRONIK). Here, the ease of implantation of the system will be demonstrated.
引用
收藏
页数:10
相关论文
共 24 条
  • [21] European clinical experience with a dual chamber single pass sensing and pacing defibrillation lead
    Gradaus, R
    Gonska, BD
    Stellbrink, C
    Cron, T
    Tebbenjohanns, J
    Blomström-Lundqvist, C
    Himmrich, E
    Salerno, JA
    Osswald, S
    Gommer, ED
    Van Veen, BK
    Böcker, D
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (07): : 1079 - 1086
  • [22] Discrimination between ventricular and supraventricular tachycardia by dual chamber cardioverter defibrillators:: Importance of the atrial sensing function
    Israel, CW
    Grönefeld, G
    Iscolo, N
    Stöppler, C
    Hohnloser, SH
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (02): : 183 - 190
  • [23] Electrical proarrhythmia:: Induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator
    Wolpert, C
    Jung, W
    Scholl, C
    Spehl, S
    Cyran, J
    Lüderitz, B
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (08) : 859 - 863
  • [24] Improvement of myocardial contractility with leadless endocardial single-lead atrial sensing ventricular pacing in patients with prolonged PQ interval
    Guaricci, Andrea Igoren
    Santobuono, Vincenzo Ezio
    Soldato, Nicolo
    Basile, Paolo
    Bozza, Nicola
    Carella, Maria Cristina
    Siena, Paola
    Forleo, Cinzia
    Pontone, Gianluca
    Ciccone, Marco Matteo
    [J]. FUTURE CARDIOLOGY, 2024, 20 (01) : 21 - 25