A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

被引:4
|
作者
Baensch, Dietmar [1 ]
Schneider, Ralph [1 ]
Akin, Ibrahim [1 ]
Nienaber, Cristoph A. [1 ]
机构
[1] Univ Hosp Rostock, Heart Ctr Rostock, Rostock, Germany
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2012年 / 60期
关键词
Medicine; Issue; 60; Implantable defibrillator; dual chamber; single chamber; tachycardia detection;
D O I
10.3791/3750
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Implantable cardioverter-defibrillators (ICDs) terminate ventricular tachycardia (VT) and ventricular fibrillation (VF) with high efficacy and can protect patients from sudden cardiac death (SCD). However, inappropriate shocks may occur if tachycardias are misdiagnosed. Inappropriate shocks are harmful and impair patient quality of life. The risk of inappropriate therapy increases with lower detection rates programmed in the ICD. Single-chamber detection poses greater risks for misdiagnosis when compared with dual-chamber devices that have the benefit of additional atrial information. However, using a dual-chamber device merely for the sake of detection is generally not accepted, since the risks associated with the second electrode may outweigh the benefits of detection. Therefore, BIOTRONIK developed a ventricular lead called the Linox(SMART) S DX, which allows for the detection of atrial signals from two electrodes positioned at the atrial part of the ventricular electrode. This device contains two ring electrodes; one that contacts the atrial wall at the junction of the superior vena cava (SVC) and one positioned at the free floating part of the electrode in the atrium. The excellent signal quality can only be achieved by a special filter setting in the ICD (Lumax 540 and 740 VR-T DX, BIOTRONIK). Here, the ease of implantation of the system will be demonstrated.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparison study on sensing and identification of Single-Lead Atrial Sensing System, Single-Chamber and Dual-Chamber Implantable Cardioverter Defibrillator System
    Long, Qilin
    Sun, Jie
    Dong, Jianting
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C135 - C135
  • [2] The role of atrial sensing for new-onset atrial arrhythmias diagnosis and management in single-chamber implantable cardioverter-defibrillator recipients: Results from the THINGS registry
    Biffi, Mauro
    Iori, Matteo
    De Maria, Elia
    Bolognesi, Maria Giulia
    Placci, Angelo
    Calvi, Valeria
    Allocca, Giuseppe
    Ammendola, Ernesto
    Carinci, Valeria
    Boggian, Giulio
    Saporito, Davide
    Grassini, Diego
    Giacopelli, Daniele
    Statuto, Giovanni
    Ziacchi, Matteo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (04) : 846 - 853
  • [3] Implantable Cardioverter Defibrillator System with Floating Atrial Sensing Dipole: A Single-Center Experience
    Iori, Matteo
    Giacopelli, Daniele
    Quartieri, Fabio
    Bottoni, Nicola
    Manari, Antonio
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (10): : 1265 - 1273
  • [4] Ability to remotely monitor atrial high-rate episodes using a single-chamber implantable cardioverter-defibrillator with a floating atrial sensing dipole
    Hindricks, Gerhard
    Theuns, Dominic A.
    Bar-Lev, David
    Anguera, Ignasi
    Ayala Paredes, Felix Alejandro
    Arnold, Martin
    Geller, J. Christoph
    Merkely, Bela
    Dyrda, Katia Marjolaine
    Perings, Christian
    Maglia, Giampiero
    Ploux, Sylvain
    Meyhoefer, Juergen
    Blomstroem-Lundqvist, Carina
    Karjalainen, Pasi
    Liang, Yanchun
    Diemberger, Igor
    Wranicz, Jerzy Krzysztof
    Barr, Craig
    Quartieri, Fabio
    Timmel, Tobias
    Bollmann, Andreas
    EUROPACE, 2023, 25 (05):
  • [5] Atrial sensing performance of a recently developed defibrillation lead with a free-floating atrial dipole connected to a single chamber defibrillator with enhanced atrial sensing characteristics
    Zerm, T
    Schmitz, D
    Bondke, HJ
    Lemke, B
    Wiegand, U
    Tiroke, A
    Mitzenheim, S
    Schuchert, A
    EUROPEAN HEART JOURNAL, 2003, 24 : 275 - 275
  • [6] Isorhythmic dissociation with smart sensing in a dual-chamber implantable cardioverter defibrillator
    Strohmer, Bernhard
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (07): : 765 - 768
  • [7] Myopotential sensing by a dual chamber implantable cardioverter defibrillator: Two case reports
    Deshmukh, P
    Anderson, K
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (07) : 767 - 772
  • [8] Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing
    Kühlkamp, V
    Dörnberger, V
    Mewis, C
    Suchalla, R
    Bosch, RF
    Seipel, L
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (07) : 905 - 915
  • [9] Complications associated with implantable cardioverter defibrillator implantation: Single chamber versus atrioventricular devices
    Verdino, RJ
    Russo, AM
    Kocovic, DZ
    Pavri, BB
    Hsia, HH
    Patel, VV
    Ashar, M
    Callans, DJ
    Marchlinski, FE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 123A - 124A
  • [10] Trends in Inappropriate Sensing of the Subcutaneous Implantable Defibrillator
    Brouwer, Tom F.
    Quast, Anne-Floor
    Kooiman, Kirsten
    Baalman, Sarah
    Knops, Reinoud
    CIRCULATION, 2017, 136