Background: This study exploits the speed benefits of echo-planar spectroscopic imaging (EPSI) to acquire lipid spectra of skeletal muscle. The main purpose was to develop a high-resolution EPSI technique for clinical MR scanner, to visualise the bulk magnetic susceptibility (BMS) shifts of extra-myocellular lipid (EMCL) spectral lines, and to investigate the feasibility of this method for the assessment of intra-myocellular (IMCL) lipids. Methods: The study group consisted of six healthy volunteers. A two dimensional EPSI sequence with point-resolved spectroscopy (PRESS) spatial localization was implemented on a 3T clinical MR scanner. Measurements were performed by means of 64664 spatial matrix and nominal voxel size 363615 mm(3). The total net measurement time was 3 min 12 sec for non-water-suppressed (1 acquisition) and 12 min 48 sec for water-suppressed scans (4 acquisitions). Results: Spectra of the human calf had a very good signal-to-noise ratio and linewidths sufficient to differentiate IMCL resonances from EMCL. The use of a large spatial matrix reduces inter-voxel signal contamination of the strong EMCL signals. Small voxels enabled visualisation of the methylene EMCL spectral line splitting and their BMS shifts up to 0.5 ppm relative to the correspondent IMCL line. The mean soleus muscle IMCL content of our six volunteers was 0.30 +/- 0.10 vol% (range 0.18-0.46) or 3.6 +/- 1.2 mmol/kg wet weight (range: 2.1-5.4). Conclusion: This study demonstrates that high-spatial resolution PRESS EPSI of the muscle lipids is feasible on standard clinical scanners.
引用
收藏
页数:9
相关论文
共 43 条
[1]   In vivo determination of intra-myocellular lipids in human muscle by means of localized H-1-MR-spectroscopy [J].
Boesch, C ;
Slotboom, J ;
Hoppeler, H ;
Kreis, R .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :484-493
[2]   Role of proton MR for the study of muscle lipid metabolism [J].
Boesch, Chris ;
Machann, Juergen ;
Vermathen, Peter ;
Schick, Fritz .
NMR IN BIOMEDICINE, 2006, 19 (07) :968-988
[3]   High-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding [J].
Chen, Albert P. ;
Cunningham, Charles H. ;
Ozturk-Isik, Esin ;
Xu, Duan ;
Hurd, Ralph E. ;
Kelley, Douglas A. C. ;
Pauly, John M. ;
Kurhanewicz, John ;
Nelson, Sarah J. ;
Vigneron, Daniel B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) :1288-1292
[4]  
CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
[5]   Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging [J].
Cunningham, CH ;
Vigneron, DB ;
Chen, AP ;
Xu, D ;
Nelson, SJ ;
Hurd, RE ;
Kelley, DA ;
Pauly, JM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1286-1289
[6]   Assessment of 3D proton MR echo-planar spectroscopic imaging using automated spectral analysis [J].
Ebel, A ;
Soher, BJ ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1072-1078
[7]   MEASUREMENTS OF MAGNETIC-FIELD VARIATIONS IN THE HUMAN BRAIN USING A 3D-FT MULTIPLE GRADIENT-ECHO TECHNIQUE [J].
ERICSSON, A ;
WEIS, J ;
HEMMINGSSON, A ;
WIKSTROM, M ;
SPERBER, GO .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :171-177
[8]   Spectroscopic imaging using concentrically circular echo-planar trajectories in vivo [J].
Furuyama, Jon K. ;
Wilson, Neil E. ;
Thomas, M. Albert .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) :1515-1522
[9]  
Guimaraes AR, 1999, MAGNET RESON MED, V41, P877, DOI 10.1002/(SICI)1522-2594(199905)41:5<877::AID-MRM4>3.0.CO
[10]  
2-3