Determination of cadmium in environmental and biological reference materials using isotope dilution analysis with a double focusing ICP-MS: a comparison with quadrupole ICP-MS

被引:0
作者
Valles Mota, JP [1 ]
Encinar, JR [1 ]
de la Campa, MRF [1 ]
Alonso, JIG [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/a901753d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A detailed examination of the performance of a double focusing (DF) sector field ICP-MS (Element, Finnigan MAT) for the ID-ICP-MS determination of cadmium in biological and environmental samples is described and compared with a quadrupole-based instrument (HP4500, Hewlett Packard). Experimental parameters governing the instrumental precision and accuracy for isotope ratio measurements of cadmium in the DF-ICP-MS are first characterized. Systematic errors, including dead time, mass bias effects and spectroscopic interferences, can be easily corrected in the two instruments studied. Detector dead time has only to be taken into account using the DF-ICP-MS. Typical isotope ratio precisions of 0.2-0.3% can be obtained routinely with both instruments. However, the precision of the measurements in the DF-ICP-MS can be improved (< 0.1%) by increasing the number of scans. Moreover, for very low cadmium concentrations the DF-ICP-MS at low resolution setting (R=300) can provide better isotope ratio precision than the quadrupole ICP-MS because of its higher sensitivity. Both ICP-MS instruments were successfully applied to the determination of very low levels of cadmium by ID-ICP-MS (by both conventional and on-line ID modes) in biological and environmental certified reference materials, including Freeze-Dried Urine NIST SRM-2670, Horse Kidney IAEA H-8, Lichens BCR TP-25, Marine Sediment PACS-1 and Riverine Water SLRS-3. Combined uncertainty associated with the determinations is addressed.
引用
收藏
页码:1467 / 1473
页数:7
相关论文
共 50 条
[41]   Time-of-flight ICP-MS laser ablation zircon geochronology: assessment and comparison against quadrupole ICP-MS [J].
Thompson, Jay M. ;
Danyushevsky, Leonid, V ;
Borovinskaya, Olga ;
Tanner, Martin .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (10) :2282-2297
[42]   THE ANALYSIS OF GEOLOGICALS USING ICP-MS [J].
LUNDSTROM, CC ;
BOWER, NW ;
GLADNEY, ES .
ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 :33-CHED
[43]   COMPARISON OF QUADRUPOLE ICP-MS AND MAGNETIC-SECTOR ICP-MS FOR THE ANALYSIS OF U-TH SERIES ISOTOPES IN NATURAL SAMPLES [J].
SHAW, TJ .
ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 :105-NUCL
[44]   RADIONUCLIDE ANALYSIS USING ICP-MS [J].
GONG, ML .
ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 :72-ANYL
[45]   Analysis of light lithophile elements (Li, Be, B) by laser ablation ICP-MS: Comparison between magnetic sector and quadrupole ICP-MS [J].
Kent, Adam J. R. ;
Ungererz, C. A. Andy .
AMERICAN MINERALOGIST, 2006, 91 (8-9) :1401-1411
[46]   A comparison of double-focusing sector field ICP-MS, ICP-OES and octopole collision cell ICP-MS for the high-accuracy determination of calcium in human serum [J].
Simpson, LA ;
Hearn, R ;
Merson, S ;
Catterick, T .
TALANTA, 2005, 65 (04) :900-906
[47]   DETERMINATION OF PB AND CD IN WHOLE-BLOOD USING ISOTOPE-DILUTION ICP-MS [J].
STROH, A .
ATOMIC SPECTROSCOPY, 1993, 14 (05) :141-143
[48]   EDXRF and ICP-MS analysis of environmental samples [J].
Nguyen, TH ;
Boman, J ;
Leermakers, M .
X-RAY SPECTROMETRY, 1998, 27 (04) :265-276
[49]   EDXRF and ICP-MS Analysis of Environmental Samples [J].
Physics and Engineering Physics, Chalmers University of Technology, S-412 96 Gothenburg, Sweden ;
不详 ;
不详 .
X-Ray Spectrom., 4 (265-276)
[50]   Interlaboratory studies for the analysis of metal ions in solution by isotope dilution ICP-MS [J].
Nonose, N ;
Hioki, A ;
Kurahashi, M ;
Kubota, M .
BUNSEKI KAGAKU, 1998, 47 (04) :239-247