Determination of cadmium in environmental and biological reference materials using isotope dilution analysis with a double focusing ICP-MS: a comparison with quadrupole ICP-MS

被引:0
|
作者
Valles Mota, JP [1 ]
Encinar, JR [1 ]
de la Campa, MRF [1 ]
Alonso, JIG [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/a901753d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A detailed examination of the performance of a double focusing (DF) sector field ICP-MS (Element, Finnigan MAT) for the ID-ICP-MS determination of cadmium in biological and environmental samples is described and compared with a quadrupole-based instrument (HP4500, Hewlett Packard). Experimental parameters governing the instrumental precision and accuracy for isotope ratio measurements of cadmium in the DF-ICP-MS are first characterized. Systematic errors, including dead time, mass bias effects and spectroscopic interferences, can be easily corrected in the two instruments studied. Detector dead time has only to be taken into account using the DF-ICP-MS. Typical isotope ratio precisions of 0.2-0.3% can be obtained routinely with both instruments. However, the precision of the measurements in the DF-ICP-MS can be improved (< 0.1%) by increasing the number of scans. Moreover, for very low cadmium concentrations the DF-ICP-MS at low resolution setting (R=300) can provide better isotope ratio precision than the quadrupole ICP-MS because of its higher sensitivity. Both ICP-MS instruments were successfully applied to the determination of very low levels of cadmium by ID-ICP-MS (by both conventional and on-line ID modes) in biological and environmental certified reference materials, including Freeze-Dried Urine NIST SRM-2670, Horse Kidney IAEA H-8, Lichens BCR TP-25, Marine Sediment PACS-1 and Riverine Water SLRS-3. Combined uncertainty associated with the determinations is addressed.
引用
收藏
页码:1467 / 1473
页数:7
相关论文
共 50 条
  • [31] Multi-element isotope dilution analyses using ICP-MS
    Volpe, A.M.
    Atomic Energy of Canada Limited, AECL (Report), 1996, (11342):
  • [32] Quantitative correction of matrix effects in the determination of copper in human serum by isotope dilution quadrupole ICP-MS
    Feng, Liuxing
    Wang, Jun
    Li, Hongmei
    Cui, Yanjie
    Lu, Hai
    Shi, Naijie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (10) : 2046 - 2052
  • [33] Determination of iodine and molybdenum in milk by quadrupole ICP-MS
    Reid, Helen J.
    Basharnmakh, Abdul A.
    Goodall, Phillip S.
    Landon, Mark R.
    O'Connor, Ciaran
    Sharp, Barry L.
    TALANTA, 2008, 75 (01) : 189 - 197
  • [34] Determination of plutonium concentrations and isotope ratios in environmental samples with a double-focusing sector field ICP-MS
    Rodushkin, I
    Lindahl, P
    Holm, E
    Roos, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 423 (2-3): : 472 - 479
  • [35] Determination of neptunium in plutonium materials by ICP-MS
    Xu, N.
    Gallimore, D.
    Martinez, A.
    Townsend, L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 297 (01) : 127 - 132
  • [36] Determination of neptunium in plutonium materials by ICP-MS
    N. Xu
    D. Gallimore
    A. Martinez
    L. Townsend
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 297 : 127 - 132
  • [37] Application of isotope dilution ICP-MS techniques to quantitative proteomics
    Bettmer, Joerg
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (08) : 3495 - 3502
  • [38] Strategies for isotope ratio measurements with a double focusing sector field ICP-MS
    M. Hamester
    D. Wiederin
    J. Wills
    W. Kerl
    C. B. Douthitt
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 495 - 498
  • [39] Strategies for isotope ratio measurements with a double focusing sector field ICP-MS
    Hamester, M
    Wiederin, D
    Wills, J
    Kerl, W
    Douthitt, CB
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05): : 495 - 497
  • [40] Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS
    Boulyga, SF
    Heumann, KG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 291 - 296