TESTING SYSTEM SET-UP TO EVALUATE ACOUSTIC INDUCED VIBRATION

被引:0
|
作者
Mann, . J. Adin, III [1 ]
Eilers, Daniel [1 ]
Jackson, Trent [1 ]
Swindell, Rob [2 ]
Middleton, Christopher [2 ]
Arnett, David [3 ]
Horder, Nicolas [4 ]
Izuchi, Hisao [5 ]
Evans, Geoff [6 ]
机构
[1] Fisher Controls Int LLC, Emerson Proc Management, Marshalltown, IA USA
[2] Wood Grp Kenny, Southampton, Hants, England
[3] Chevron Energy Technol Co, Houston, TX USA
[4] Xodus Grp, Aberdeen, Scotland
[5] Chiyoda Corp, Yokohama, Kanagawa, Japan
[6] BP Explorat & Prod Co Ltd, Sunbury On Thames, Middx, England
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A consortium of companies is collaborating in a Joint Industry Project (JIP) for Acoustic Induced Vibration (MV). Laboratory testing is one of the work areas of the JIP. The goals of the tests are to evaluate typical pipe fittings for AIV induced fatigue, to rank order their AIV risk and to obtain data for validation of computational models. An NPS6x8 (6R8) pressure safety valve was the flow and noise input to a 10S piping system, which consisted of an NPS12 tailpipe input into an NPS12x20 tee. Small bore connectors (SBCs) were included in both the NPS12 tailpipe and the NPS20 header. The type of fitting used as the connection between the SBC and the pipe was varied. The system was operating in a Carucci-Mueller acoustic power of around 175 dB. Vibration acceleration response of the system was measured, and dynamic strain data was also gathered to evaluate fatigue life. The piping and data acquisition system setup will be discussed along with the type of results that are being obtained.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Experimental set-up
    Prace Naukowe Instytutu Technologii Budowy Maszyn Politechniki Wroclawskiej, 1991, 48 (13):
  • [32] An acoustic set up for the vibration analysis of silicon wafers
    Mitterhofer, S.
    Puehringer, J. D.
    Schlosser, V.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 8068 - 8073
  • [33] Vibration reduction in a set-up of two split type Stirling cryocoolers
    Rijpma, AP
    Verberne, JFC
    Witbreuk, EHR
    terBrake, HJM
    CRYOCOOLERS 9, 1997, : 727 - 736
  • [34] Design of a pulse-echo set-up and measurement of acoustic velocity
    De, S.S.
    Jana, D.
    Ghosh, A.K.
    Haldar, J.C.
    Electron Technology (Warsaw), 1993, 26 (2-3): : 77 - 89
  • [35] EXPERIMENTAL SET-UP FOR THE STUDY OF ACOUSTIC-EMISSION FROM MATERIALS
    RAO, BM
    KUMAR, JS
    RAO, SPM
    SURYANARAYANA, M
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1982, 20 (04) : 284 - 288
  • [36] Development of an automated fixture set-up system for inspection
    B. K. A. Ngoi
    M. L. Tay
    C. S. Wong
    The International Journal of Advanced Manufacturing Technology, 1997, 13 : 342 - 349
  • [37] MULTIPRODUCT INVENTORY SYSTEM WITH INTERACTIVE SET-UP COSTS
    ANDRES, F
    EMMONS, H
    MANAGEMENT SCIENCE SERIES A-THEORY, 1975, 21 (09): : 1055 - 1063
  • [38] THE SET-UP OF A SYSTEM FOR MITOTIC-ACTIVITY SCORING
    SMEULDERS, AWM
    BAAK, JPA
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1983, 5 (03): : 221 - 222
  • [39] Set-up generation system for a tandem cold mill
    Ferreira, HC
    Sales, RM
    Pires, CTD
    Conference Record of the 2005 IEEE Industry Applications Conference, Vols 1-4, 2005, : 508 - 514
  • [40] AUTOMATIC SET-UP OF TOOL MONITORS BY A CAM SYSTEM
    ANSELMETTI, B