Time-resolved 3D contrast-enhanced MRA of an extended FOV using continuous table motion

被引:29
|
作者
Madhuranthakam, AJ [1 ]
Kruger, DG [1 ]
Riederer, SJ [1 ]
Glockner, JF [1 ]
Hu, HCH [1 ]
机构
[1] Mayo Clin, MR Res Lab, Dept Radiol, Coll Med, Rochester, MN 55905 USA
关键词
moving-table MRI; peripheral MRA; time-resolved 3D MRA; extended-FOV MRI; contrast kinetics;
D O I
10.1002/mrm.10729
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is presented for acquiring 3D time-resolved MR images of an extended (> 100 cm) longitudinal field of view (FOV), as used for peripheral MR angiographic runoff studies. Previous techniques for long-FOV peripheral MRA have generally provided a single image (i.e., with no time resolution). The technique presented here generates a time series of 3D images of the FOV that lies within the homogeneous volume of the magnet. This is achieved by differential sampling of 3D k-space during continuous motion of the patient table. Each point in the object is interrogated in five consecutive 3D image sets generated at 2.5-s intervals. The method was tested experimentally in eight human subjects, and the leading edge of the bolus was observed in real time and maintained within the imaging FOV. The data revealed differential bolus velocities along the vasculature of the legs. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:568 / 576
页数:9
相关论文
共 50 条
  • [41] Postoperative assessment of extracranial-intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging
    Tsuchiya, K
    Honya, K
    Fujikawa, A
    Tateishi, H
    Shiokawa, Y
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (09) : 2243 - 2247
  • [42] Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients
    Alex Frydrychowicz
    Thorsten A. Bley
    Jan T. Winterer
    Andreas Harloff
    Mathias Langer
    Jürgen Hennig
    Michael Markl
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 187 - 195
  • [43] Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients
    Frydrychowicz, Alex
    Bley, Thorsten A.
    Winterer, Jan T.
    Harloff, Andreas
    Langer, Mathias
    Hennig, Juergen
    Markl, Michael
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (04) : 187 - 195
  • [44] High Temporal and Spatial Resolution 3D Time-Resolved Contrast-Enhanced Magnetic Resonance Angiography of the Hands and Feet
    Haider, Clifton R.
    Riederer, Stephen J.
    Borisch, Eric A.
    Glockner, James F.
    Grimm, Roger C.
    Hulshizer, Thomas C.
    Macedo, Thanila A.
    Mostardi, Petrice M.
    Rossman, Phillip J.
    Vrtiska, Terri J.
    Young, Phillip M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) : 2 - 12
  • [45] Improve temporal and spatial resolution in contrast-enhanced 3D MRA using paralle imaging
    Quijano, CV
    Chen, Q
    Li, W
    Storey, P
    Mai, VM
    Edelman, RT
    RADIOLOGY, 2002, 225 : 571 - 572
  • [46] Intracranial time-resolved contrast-enhanced MR angiography at 3T
    Cashen, TA
    Carr, JC
    Shin, W
    Walker, MT
    Futterer, SF
    Shaibani, A
    McCarthy, FM
    Carroll, TJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (04) : 822 - 829
  • [47] Contrast-Enhanced Time-Resolved MRA for Follow-Up of Intracranial Aneurysms Treated with the Pipeline Embolization Device
    Boddu, S. R.
    Tong, F. C.
    Dehkharghani, S.
    Dion, J. E.
    Saindane, A. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) : 2112 - 2118
  • [48] Use of anisotropic resolution in azimuthally undersampled time-resolved 3D MRA
    Vigen, KK
    Holden, JE
    Block, WF
    Grist, TM
    Mistretta, CA
    RADIOLOGY, 1999, 213P : 286 - 286
  • [49] Evaluation of large intracranial aneurysms by combined application of cine MRA and 3D contrast-enhanced MRA
    Zhu, W
    Qi, J
    Xia, L
    Feng, D
    Wang, C
    RADIOLOGY, 2002, 225 : 522 - 522
  • [50] Time-resolved contrast-enhanced MR angiography of intracranial lesions
    Zou, Zhitong
    Ma, Lin
    Cheng, Liuquan
    Cai, Youquan
    Meng, Xianghui
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 692 - 699