Evaluation of LeadCare Ultra® as an initial screen for elevated blood lead levels

被引:3
作者
Johnson, Lisa M. [1 ]
Lynch, Maureen [1 ]
Johnson, Cindy [1 ]
Karger, Amy B. [1 ]
机构
[1] Univ Minnesota, Dept Lab Med & Pathol, 420 Delaware St SE MMC 609, Minneapolis, MN 55455 USA
关键词
LeadCare; ICP-MS; Lead; Screen; Children; WHOLE-BLOOD; CAPILLARY;
D O I
10.1016/j.clinbiochem.2019.02.010
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: The LeadCare Ultra (R) (LCU) was compared to inductively coupled plasma mass spectrometry ICP-MS for use as a screening test for elevated blood lead levels (BLLs) in capillary samples from children. Methods: During the validation, method comparisons between LCU and ICP-MS were analyzed to determine the bias above, near, and below the BLL cut-off of 5 mu g/dL. Additionally, capillary samples that screened positive by LCU (above the 5 mu g/dL cut-off) were compared to venous samples analyzed by ICP-MS for confirmatory testing. Results: LCU had a positive bias (1.7 mu g/dL) below the cut-off of BLL < 5 mu g/dL, no bias near the cut-off from BLL 5-10 mu g/dL, and a negative bias (-0.8 mu g/dL) for BLL > 10 mu g/dL compared to ICP-MS. Of the 59 capillary samples that screened positive by LCU between May of 2017 to April of 2018, 19 were confirmed positive by ICP-MS, 30 were confirmed negative by ICP-MS, and 10 did not have a confirmed result. Conclusion: The LCU assay is an acceptable screen for capillary samples with the BLL cut-off of 5 mu g/dL.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 18 条
  • [1] [Anonymous], 2013, C40A2 CLSI
  • [2] An interactive website for analytical method comparison and bias estimation
    Bahar, Burak
    Tuncel, Ayse F.
    Holmes, Earle W.
    Holmes, Daniel T.
    [J]. CLINICAL BIOCHEMISTRY, 2017, 50 (18) : 1025 - 1029
  • [3] Bannon DI, 2001, CLIN CHEM, V47, P1703
  • [4] Blood lead misclassification due to defective LeadCare® blood lead testing equipment
    Bossarte, Robert M.
    Brown, Mary Jean
    Jones, Robert L.
    [J]. CLINICAL CHEMISTRY, 2007, 53 (05) : 994 - 995
  • [5] Measurement Challenges at Low Blood Lead Levels
    Caldwell, Kathleen L.
    Cheng, Po-Yung
    Jarrett, Jeffery M.
    Makhmudov, Amir
    Vance, Kathryn
    Ward, Cynthia D.
    Jones, Robert L.
    Mortensen, Mary E.
    [J]. PEDIATRICS, 2017, 140 (02)
  • [6] CDC, LOW LEV LEAD EXP HAR
  • [7] Center for Disease Control, SOURC LEAD
  • [8] FDA, SAF ISS MAG DIAGN LE
  • [9] Determination of essential and toxic metals in blood by ICP-MS with calibration in synthetic matrix
    Gajek, Ryszard
    Barley, Frank
    She, Jianwen
    [J]. ANALYTICAL METHODS, 2013, 5 (09) : 2193 - 2202
  • [10] Johnson NH, 1997, ANN CLIN LAB SCI, V27, P179