Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels

被引:20
作者
Moutsatsos, A. [1 ]
Karaiskos, P. [1 ,2 ]
Petrokokkinos, L. [3 ]
Sakelliou, L. [3 ]
Pantelis, E. [1 ]
Georgiou, E. [1 ]
Torrens, M. [2 ]
Seimenis, I. [4 ]
机构
[1] Univ Athens, Sch Med, Med Phys Lab, GR-11527 Athens, Greece
[2] Hygeia Hosp, Gamma Knife Dept, Athens 15123, Greece
[3] Univ Athens, Dept Phys, Nucl & Particle Phys Sect, GR-15771 Athens, Greece
[4] Democritus Univ Thrace, Med Phys Lab, Sch Med, Alexandroupolis 68100, Greece
关键词
geometric uncertainty; distortion; MRI; Gamma Knife; COMPLETE DISTORTION CORRECTION; MAGNETIC-RESONANCE IMAGES; MR-IMAGES; STEREOTACTIC LOCALIZATION; FIELD INHOMOGENEITIES; TRIGEMINAL NEURALGIA; SPATIAL DISTORTION; PROSTATE-CANCER; ACCURACY; DOSIMETRY;
D O I
10.1118/1.4789922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work proposes and implements an experimental methodology, based on polymer gels, for assessing the total geometric uncertainty and characterizing its contributors in Gamma Knife (GK) radiosurgery. Methods: A treatment plan consisting of 26, 4-mm GK single shot dose distributions, covering an extended region of the Leksell stereotactic space, was prepared and delivered to a polymer gel filled polymethyl methacrylate (PMMA) head phantom (16 cm diameter) used to accurately reproduce every link in the GK treatment chain. The center of each shot served as a "control point" in the assessment of the GK total geometric uncertainty, which depends on (a) the spatial dose delivery uncertainty of the PERFEXION GK unit used in this work, (b) the spatial distortions inherent in MR images commonly used for target delineation, and (c) the geometric uncertainty contributor associated with the image registration procedure performed by the Leksell GammaPlan (LGP) treatment planning system (TPS), in the case that registration is directly based on the apparent fiducial locations depicted in each MR image by the N-shaped rods on the Leksell localization box. The irradiated phantom was MR imaged at 1.5 T employing a T2-weighted pulse sequence. Four image series were acquired by alternating the frequency encoding axis and reversing the read gradient polarity, thus allowing the characterization of the MR-related spatial distortions. Results: MR spatial distortions stemming from main field (B-0) inhomogeneity as well as from susceptibility and chemical shift phenomena (also known as sequence dependent distortions) were found to be of the order of 0.5 mm, while those owing to gradient nonlinearities (also known as sequence independent distortions) were found to increase with distance from the MR scanner isocenter extending up to 0.47 mm at an Euclidean distance of 69.6 mm Regarding the LGP image registration procedure, the corresponding average contribution to the total geometric uncertainty ranged from 0.34 to 0.80 mm The average total geometric uncertainty, which also includes the GK spatial dose delivery uncertainty, was found equal to (0.88 +/- 0.16), (0.88 +/- 0.26), (1.02 +/- 0.09), and (1.15 +/- 0.24) mm for the MR image series acquired with the read gradient polarity (direction) set toward right, left, posterior, and anterior, respectively. Conclusions: The implemented methodology seems capable of assessing the total geometric uncertainty, as well as of characterizing its contributors, ascribed to the entire GK treatment delivery (i.e., from MR imaging to GK dose delivery) for an extended region of the Leksell stereotactic space. Results obtained indicate that the selection of both the frequency encoding axis and the read gradient polarity during MRI acquisition may affect the magnitude as well as the spatial components of the total geometric uncertainty. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4789922]
引用
收藏
页数:14
相关论文
共 50 条
  • [41] An investigation of eye lens dose of stereotactic radiosurgery for trigeminal neuralgia using Leksell Gamma Knife model C
    Liang, Cheng-Loong
    Ho, Meng-Wei
    Lu, Kang
    Tsai, Yu-Duan
    Liliang, Po-Chou
    Wang, Kuo-Wei
    Chen, Han-Jung
    JOURNAL OF NEUROSURGERY, 2006, 105 : 112 - 116
  • [42] Stereotactic radiosurgery of essential trigeminal neuralgia using Leksell Gamma Knife model C with automatic positioning system
    Hayashi, Motohiro
    Chernov, Mikhail
    Tamura, Noriko
    Taira, Takaomi
    Izawa, Masahiro
    Yomo, Shoji
    Nagai, Mariko
    Chang, Cheng-Siu
    Ivanov, Pavel
    Tamura, Manabu
    Muragaki, Yoshihiro
    Okada, Yoshikazu
    Iseki, Hiroshi
    Takakura, Kintomo
    NEUROSURGICAL REVIEW, 2011, 34 (04) : 497 - 508
  • [43] Evaluation of inverse treatment planning for gamma knife radiosurgery using fMRI brain activation maps as organs at risk
    Abramian, David
    Blystad, Ida
    Eklund, Anders
    MEDICAL PHYSICS, 2023, 50 (09) : 5297 - 5311
  • [44] Dosimetric characterization of hypofractionated Gamma Knife radiosurgery of large or complex brain tumors versus linear accelerator-based treatments
    Dong, Peng
    Perez-Andujar, Angelica
    Pinnaduwage, Dilini
    Braunstein, Steve
    Theodosopoulos, Philip
    McDermott, Michael
    Sneed, Penny
    Ma, Lijun
    JOURNAL OF NEUROSURGERY, 2016, 125 : 97 - 103
  • [45] Stereotaktische Konvergenzbestrahlung großer uvealer Melanome mit dem Gamma-Knife Vorläufige Ergebnisse bei 100 PatientenStereotactic radiosurgery using the Gamma Knife for large uveal melanomas
    A. J. Mueller
    U. Schaller
    S. Talies
    G. A. Horstmann
    B. Wowra
    A. Kampik
    Der Ophthalmologe, 2003, 100 (2): : 122 - 128
  • [46] Postoperative stereotactic radiosurgery and hypofractionated radiotherapy for brain metastases using Gamma Knife and CyberKnife - a dual-center analysis
    Kuebler, Jens
    Wester-Ebbinghaus, Michael
    Wenz, Frederik
    Stieler, Florian
    Bathen, Bastian
    Mai, Sabine K.
    Wolff, Robert
    Haenggi, Daniel
    Blanck, Oliver
    Giordano, Frank Anton
    JOURNAL OF NEUROSURGICAL SCIENCES, 2020, : 22 - 30
  • [47] Characterization of a new polymer gel for radiosurgery dosimetry using Magnetic Resonance Imaging
    Petrokokkinos, L.
    Kozicki, M.
    Pantelis, E.
    Antypas, C.
    Fijuth, J.
    Karaiskos, P.
    Sakelliou, L.
    Seimenis, I.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [48] Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation
    Pourfallah, Tayyeb Allahverdi
    Allahverdi, Mahmoud
    Alam, Nader Riahi
    Ay, Mohammad-Reza
    Zahmatkesh, Mohammad-Hasan
    MEDICAL PHYSICS, 2009, 36 (07) : 3002 - 3012
  • [49] Quantitative assessment of choroidal melanoma response to gamma knife radiosurgery (GKR) treatment with contrast-enhanced ultrasound (CEUS): preliminary results
    Di Nicola, Maura
    Miserocchi, Elisabetta
    Venturini, Massimo
    Colantoni, Caterina
    Del Maschio, Alessandro
    Ratiglia, Roberto
    Bandello, Francesco
    Modorati, Giulio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [50] Lesion delineation framework for vestibular schwannoma, meningioma and brain metastasis for gamma knife radiosurgery using stereotactic magnetic resonance images
    Lee, Wei-Kai
    Yang, Huai-Che
    Lee, Cheng-Chia
    Lu, Chia-Feng
    Wu, Chih-Chun
    Chung, Wen-Yuh
    Wu, Hsiu-Mei
    Guo, Wan-Yuo
    Wu, Yu-Te
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 229