Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels

被引:20
作者
Moutsatsos, A. [1 ]
Karaiskos, P. [1 ,2 ]
Petrokokkinos, L. [3 ]
Sakelliou, L. [3 ]
Pantelis, E. [1 ]
Georgiou, E. [1 ]
Torrens, M. [2 ]
Seimenis, I. [4 ]
机构
[1] Univ Athens, Sch Med, Med Phys Lab, GR-11527 Athens, Greece
[2] Hygeia Hosp, Gamma Knife Dept, Athens 15123, Greece
[3] Univ Athens, Dept Phys, Nucl & Particle Phys Sect, GR-15771 Athens, Greece
[4] Democritus Univ Thrace, Med Phys Lab, Sch Med, Alexandroupolis 68100, Greece
关键词
geometric uncertainty; distortion; MRI; Gamma Knife; COMPLETE DISTORTION CORRECTION; MAGNETIC-RESONANCE IMAGES; MR-IMAGES; STEREOTACTIC LOCALIZATION; FIELD INHOMOGENEITIES; TRIGEMINAL NEURALGIA; SPATIAL DISTORTION; PROSTATE-CANCER; ACCURACY; DOSIMETRY;
D O I
10.1118/1.4789922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work proposes and implements an experimental methodology, based on polymer gels, for assessing the total geometric uncertainty and characterizing its contributors in Gamma Knife (GK) radiosurgery. Methods: A treatment plan consisting of 26, 4-mm GK single shot dose distributions, covering an extended region of the Leksell stereotactic space, was prepared and delivered to a polymer gel filled polymethyl methacrylate (PMMA) head phantom (16 cm diameter) used to accurately reproduce every link in the GK treatment chain. The center of each shot served as a "control point" in the assessment of the GK total geometric uncertainty, which depends on (a) the spatial dose delivery uncertainty of the PERFEXION GK unit used in this work, (b) the spatial distortions inherent in MR images commonly used for target delineation, and (c) the geometric uncertainty contributor associated with the image registration procedure performed by the Leksell GammaPlan (LGP) treatment planning system (TPS), in the case that registration is directly based on the apparent fiducial locations depicted in each MR image by the N-shaped rods on the Leksell localization box. The irradiated phantom was MR imaged at 1.5 T employing a T2-weighted pulse sequence. Four image series were acquired by alternating the frequency encoding axis and reversing the read gradient polarity, thus allowing the characterization of the MR-related spatial distortions. Results: MR spatial distortions stemming from main field (B-0) inhomogeneity as well as from susceptibility and chemical shift phenomena (also known as sequence dependent distortions) were found to be of the order of 0.5 mm, while those owing to gradient nonlinearities (also known as sequence independent distortions) were found to increase with distance from the MR scanner isocenter extending up to 0.47 mm at an Euclidean distance of 69.6 mm Regarding the LGP image registration procedure, the corresponding average contribution to the total geometric uncertainty ranged from 0.34 to 0.80 mm The average total geometric uncertainty, which also includes the GK spatial dose delivery uncertainty, was found equal to (0.88 +/- 0.16), (0.88 +/- 0.26), (1.02 +/- 0.09), and (1.15 +/- 0.24) mm for the MR image series acquired with the read gradient polarity (direction) set toward right, left, posterior, and anterior, respectively. Conclusions: The implemented methodology seems capable of assessing the total geometric uncertainty, as well as of characterizing its contributors, ascribed to the entire GK treatment delivery (i.e., from MR imaging to GK dose delivery) for an extended region of the Leksell stereotactic space. Results obtained indicate that the selection of both the frequency encoding axis and the read gradient polarity during MRI acquisition may affect the magnitude as well as the spatial components of the total geometric uncertainty. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4789922]
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Gamma Knife Stereotactic Radiosurgery for Brain Metastases Using Only 3 Pins
    Ho, Jennifer C.
    Luo, Dershan
    Guha-Thakurta, Nandita
    Ferguson, Sherise D.
    Ghia, Amol J.
    Yang, James N.
    Brown, Paul D.
    Voong, Khinh Ranh
    NEUROSURGERY, 2016, 78 (06) : 877 - 882
  • [22] 3D dose prediction for Gamma Knife radiosurgery using deep learning and data modification
    Zhang, Binghao
    Babier, Aaron
    Chan, Timothy C. Y.
    Ruschin, Mark
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 106
  • [23] Mechanical and dose delivery accuracy evaluation in radiosurgery using polymer gels
    Sandilos, Panagiotis
    Tatsis, Elias
    Vlachos, Lampros
    Dardoufas, Constantinos
    Karaiskos, Pantelis
    Georgiou, Evangelos
    Baras, Panagiotis
    Kipouros, Panagiotis
    Torrens, Michael
    Angelopoulos, Angelos
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (04): : 13 - 21
  • [24] Application of polymer dose gels for millimeter scale target/tumor pre-treatment immitation using gamma knife facility
    Jaselske, Evelina
    Adliene, Diana
    Rudzianskas, Viktoras
    Korobeinikova, Erika
    Radziunas, Andrius
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 470 (470) : 56 - 60
  • [25] Multistage stereotactic radiosurgery for large cerebral arteriovenous malformations using the Gamma Knife platform
    Ding, Chuxiong
    Hrycushko, Brian
    Whitworth, Louis
    Li, Xiang
    Nedzi, Lucien
    Weprin, Bradley
    Abdulrahman, Ramzi
    Welch, Babu
    Jiang, Steve B.
    Wardak, Zabi
    Timmerman, Robert D.
    MEDICAL PHYSICS, 2017, 44 (10) : 5010 - 5019
  • [26] Long-term geometric quality assurance of radiation focal point and cone-beam computed tomography for Gamma Knife radiosurgery system
    Ohira, Shingo
    Imae, Toshikazu
    Minamitani, Masanari
    Katano, Atsuto
    Aoki, Atsushi
    Ohta, Takeshi
    Umekawa, Motoyuki
    Shinya, Yuki
    Hasegawa, Hirotaka
    Nishio, Teiji
    Koizumi, Masahiko
    Yamashita, Hideomi
    Saito, Nobuhito
    Nakagawa, Keiichi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 389 - 395
  • [27] Assessment of intra-fraction motion during frameless image guided Gamma Knife stereotactic radiosurgery
    Li, Winnie
    Bootsma, Gregory
    Shultz, David
    Laperriere, Normand
    Millar, Barbara-Ann
    Cho, Young Bin
    Jaffray, David A.
    Chung, Caroline
    Coolens, Catherine
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 25
  • [28] Trigeminal neuralgia associated with multiple sclerosis: A multimodal assessment of brainstem plaques and response to Gamma Knife radiosurgery
    Li, Cathy Meng Fei
    Hung, Peter Shih-Ping
    Chu, Powell P. W.
    Tohyama, Sarasa
    Hodaie, Mojgan
    MULTIPLE SCLEROSIS JOURNAL, 2020, 26 (14) : 1877 - 1888
  • [29] MRI-based polymer gel dosimetry for validating plans with multiple matrices in Gamma Knife stereotactic radiosurgery
    Gopishankar, N.
    Watanabe, Yoichi
    Subbiah, Vivekanandhan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 133 - 145
  • [30] Dose verification to cochlea during gamma knife radiosurgery of acoustic schwannoma using MOSFET dosimeter
    Sharma, Sunil D.
    Kumar, Rajesh
    Akhilesh, Philomina
    Pendse, Anil M.
    Deshpande, Sudesh
    Misra, Basant K.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (04) : 528 - 531