Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels

被引:20
|
作者
Moutsatsos, A. [1 ]
Karaiskos, P. [1 ,2 ]
Petrokokkinos, L. [3 ]
Sakelliou, L. [3 ]
Pantelis, E. [1 ]
Georgiou, E. [1 ]
Torrens, M. [2 ]
Seimenis, I. [4 ]
机构
[1] Univ Athens, Sch Med, Med Phys Lab, GR-11527 Athens, Greece
[2] Hygeia Hosp, Gamma Knife Dept, Athens 15123, Greece
[3] Univ Athens, Dept Phys, Nucl & Particle Phys Sect, GR-15771 Athens, Greece
[4] Democritus Univ Thrace, Med Phys Lab, Sch Med, Alexandroupolis 68100, Greece
关键词
geometric uncertainty; distortion; MRI; Gamma Knife; COMPLETE DISTORTION CORRECTION; MAGNETIC-RESONANCE IMAGES; MR-IMAGES; STEREOTACTIC LOCALIZATION; FIELD INHOMOGENEITIES; TRIGEMINAL NEURALGIA; SPATIAL DISTORTION; PROSTATE-CANCER; ACCURACY; DOSIMETRY;
D O I
10.1118/1.4789922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work proposes and implements an experimental methodology, based on polymer gels, for assessing the total geometric uncertainty and characterizing its contributors in Gamma Knife (GK) radiosurgery. Methods: A treatment plan consisting of 26, 4-mm GK single shot dose distributions, covering an extended region of the Leksell stereotactic space, was prepared and delivered to a polymer gel filled polymethyl methacrylate (PMMA) head phantom (16 cm diameter) used to accurately reproduce every link in the GK treatment chain. The center of each shot served as a "control point" in the assessment of the GK total geometric uncertainty, which depends on (a) the spatial dose delivery uncertainty of the PERFEXION GK unit used in this work, (b) the spatial distortions inherent in MR images commonly used for target delineation, and (c) the geometric uncertainty contributor associated with the image registration procedure performed by the Leksell GammaPlan (LGP) treatment planning system (TPS), in the case that registration is directly based on the apparent fiducial locations depicted in each MR image by the N-shaped rods on the Leksell localization box. The irradiated phantom was MR imaged at 1.5 T employing a T2-weighted pulse sequence. Four image series were acquired by alternating the frequency encoding axis and reversing the read gradient polarity, thus allowing the characterization of the MR-related spatial distortions. Results: MR spatial distortions stemming from main field (B-0) inhomogeneity as well as from susceptibility and chemical shift phenomena (also known as sequence dependent distortions) were found to be of the order of 0.5 mm, while those owing to gradient nonlinearities (also known as sequence independent distortions) were found to increase with distance from the MR scanner isocenter extending up to 0.47 mm at an Euclidean distance of 69.6 mm Regarding the LGP image registration procedure, the corresponding average contribution to the total geometric uncertainty ranged from 0.34 to 0.80 mm The average total geometric uncertainty, which also includes the GK spatial dose delivery uncertainty, was found equal to (0.88 +/- 0.16), (0.88 +/- 0.26), (1.02 +/- 0.09), and (1.15 +/- 0.24) mm for the MR image series acquired with the read gradient polarity (direction) set toward right, left, posterior, and anterior, respectively. Conclusions: The implemented methodology seems capable of assessing the total geometric uncertainty, as well as of characterizing its contributors, ascribed to the entire GK treatment delivery (i.e., from MR imaging to GK dose delivery) for an extended region of the Leksell stereotactic space. Results obtained indicate that the selection of both the frequency encoding axis and the read gradient polarity during MRI acquisition may affect the magnitude as well as the spatial components of the total geometric uncertainty. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4789922]
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Characterization of system-related geometric distortions in MR images employed in Gamma Knife radiosurgery applications
    Pappas, E. P.
    Seimenis, I.
    Moutsatsos, A.
    Georgiou, E.
    Nomikos, P.
    Karaiskos, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (19) : 6993 - 7011
  • [2] Assessment of the accuracy and stability of frameless gamma knife radiosurgery
    Chung, Hyun-Tai
    Park, Woo-Yoon
    Kim, Tae Hoon
    Kim, Yong Kyun
    Chun, Kook Jin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 148 - 154
  • [3] Application of polymer gel dosimetry in gamma knife radiosurgery
    Novotny, J
    Novotny, J
    Spevácek, V
    Dvorák, P
    Cechák, T
    Liscák, R
    Brozek, G
    Tintera, J
    Vymazal, J
    JOURNAL OF NEUROSURGERY, 2002, 97 : 556 - 562
  • [4] Total workflow uncertainty of frameless radiosurgery with the Gamma Knife Icon cone-beam computed tomography
    Duggar, William N.
    Morris, Bart
    He, Rui
    Yang, Claus
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [5] Gamma knife radiosurgery using 90 Gy for trigeminal neuralgia
    Nicol, B
    Regine, WF
    Courtney, C
    Meigooni, A
    Sanders, M
    Young, B
    JOURNAL OF NEUROSURGERY, 2000, 93 : 152 - 154
  • [6] Assessment of spatial uncertainty in computed tomography-based Gamma Knife stereotactic radiosurgery process with automated positioning system
    Nakazawa, Hisato
    Komori, Masataka
    Oguchi, Hiroshi
    Shibamoto, Yuta
    Tsugawa, Takahiko
    Uchiyama, Yukio
    Kobayashi, Tatsuya
    ACTA NEUROCHIRURGICA, 2014, 156 (10) : 1929 - 1935
  • [7] Gamma knife radiosurgery using 90 Gy for trigeminal neuralgia
    Nicol, Bradley
    Regine, William F.
    Courtney, Claire
    Meigooni, Ali
    Sanders, Michael
    Young, Byron
    JOURNAL OF NEUROSURGERY, 2011, 115 : 28 - 30
  • [8] A quality assurance program in stereotactic radiosurgery using the gamma knife unit
    Stuecklschweiger, GE
    Feichtinger, K
    STRAHLENTHERAPIE UND ONKOLOGIE, 1998, 174 : 43 - 46
  • [9] Stereotactic radiosurgery using the gamma knife: Indications and results
    Kondziolka, D
    Lunsford, LD
    Flickinger, JC
    NEUROLOGIST, 1997, 3 (01) : 45 - 52
  • [10] STEREOTAXIC RADIOSURGERY USING THE GAMMA-KNIFE FOR ACOUSTIC NEUROMAS
    FOOTE, RL
    COFFEY, RJ
    SWANSON, JW
    HARNER, SG
    BEATTY, CW
    KLINE, RW
    STEVENS, LN
    HU, TC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (04): : 1153 - 1160