Potential External Contamination with Bisphenol A and Other Ubiquitous Organic Environmental Chemicals during Biomonitoring Analysis: An Elusive Laboratory Challenge

被引:113
作者
Ye, Xiaoyun [1 ]
Zhou, Xiaoliu [1 ]
Hennings, Ryan [1 ]
Kramer, Joshua [1 ]
Calafat, Antonia M. [1 ]
机构
[1] Ctr Dis Control & Prevent, Div Sci Lab, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
关键词
benzophenone-3; biomonitoring; bisphenol A; exposure assessment; parabens; reagent blank; triclosan; STANDARD REFERENCE MATERIALS; HPLC-MS/MS METHOD; HUMAN EXPOSURE; PRENATAL EXPOSURE; INDOOR DUST; HUMAN SERUM; URINE; EXTRACTION; SAMPLES; MILK;
D O I
10.1289/ehp.1206093
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
BACKGROUND: Biomonitoring studies are conducted to assess internal dose (i.e., body burden) to environmental chemicals. However, because of the ubiquitous presence in the environment of some of these chemicals, such as bisphenol A (BPA), external contamination during handling and analysis of the biospecimens collected for biomonitoring evaluations could compromise the reported concentrations of such chemicals. OBJECTIVES: We examined the contamination with the target analytes during analysis of biological specimens in biomonitoring laboratories equipped with state-of-the-art analytical instrumentation. DISCUSSIONS: We present several case studies using the quantitative determination of BPA and other organic chemicals (i.e., benzophenone-3, triclosan, parabens) in human urine, milk, and serum to identify potential contamination sources when the biomarkers measured are ubiquitous environmental contaminants. CONCLUSIONS: Contamination with target analytes during biomonitoring analysis could result from solvents and reagents, the experimental apparatus used, the laboratory environment, and/or even the analyst. For biomonotoring data to be valid-even when obtained from high-quality analytical methods and good laboratory practices-the following practices must be followed to identify and track unintended contamination with the target analytes during analysis of the biological specimens: strict quality control measures including use of laboratory blanks; replicate analyses; engineering controls (e. g., clean rooms, biosafety cabinets) as needed; and homogeneous matrix-based quality control materials within the expected concentration ranges of the study samples.
引用
收藏
页码:283 / 286
页数:4
相关论文
共 35 条
  • [31] Twenty-Four Hour Human Urine and Serum Profiles of Bisphenol A during High-Dietary Exposure
    Teeguarden, Justin G.
    Calafat, Antonia M.
    Ye, Xiaoyum
    Doerge, Daniel R.
    Churchwell, Mona I.
    Gunawan, Rudy
    Graham, Morgan K.
    [J]. TOXICOLOGICAL SCIENCES, 2011, 123 (01) : 48 - 57
  • [32] Development and validation of a method for the determination of trace alkylphenols and phthalates in the atmosphere
    Xie, ZY
    Selzer, J
    Ebinghaus, R
    Caba, A
    Ruck, W
    [J]. ANALYTICA CHIMICA ACTA, 2006, 565 (02) : 198 - 207
  • [33] Automated on-line column-switchning HPLC-MS/MS method with peak focusing for measuring parcabens, triclosan, and other environmental phenols in human milk
    Ye, Xiaoyun
    Bishop, Amber M.
    Needham, Larry L.
    Calafat, Antonia M.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 622 (1-2) : 150 - 156
  • [34] Quantification of the urinary concentrations of parabens in humans by on-line solid phase extraction-high performance liquid chromatography-isotope dilution tandem mass spectrometry
    Ye, Xiaoyun
    Kuklenyik, Zsuzsanna
    Bishop, Amber M.
    Needham, Larry L.
    Calafat, Antonia M.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 53 - 59
  • [35] Automated on-line column-switching HPLC-MS/MS method with peak focusing for the determination of nine environmental phenols in urine
    Ye, XY
    Kuklenyik, Z
    Needham, LL
    Calafat, AM
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (16) : 5407 - 5413