Dose equivalent transmission data for shielding industrial x-ray facilities up to 800 kV

被引:0
作者
Bourgois, L. [1 ]
Menard, S. [1 ]
机构
[1] CEA, DAM, DIF, F-91297 Arpajon, France
关键词
x-rays shielding; Monte Carlo calculations; industrial x-ray device; MONTE-CARLO; ATTENUATION; SPECTRA;
D O I
10.1088/1361-6498/aaae20
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The transmission factors used to calculate radiation shielding around an industrial x-ray device are determined using the MCNP6 code. The transmission factors are given for high voltages ranging between 120 and 800 kV for lead and between 200 and 800 kV for concrete. In view of the high usage intensity of industrial devices, the transmission factors are evaluated up to 1.10(-10). The parameters used in the classic equation of Archer et al are derived from the transmission data calculated here. This type of data exists in the literature, but only for voltages lower than 150 kV to meet the design demands for facilities used in the medical field. In addition, this study markedly supplements the existing data, in particular for industrial and research installations.
引用
收藏
页码:471 / 479
页数:9
相关论文
共 15 条
  • [1] Antoni R., 2017, Applied Physics of External Radiation Exposure Dosimetry and Radiation Protection
  • [2] DIAGNOSTIC-X-RAY SHIELDING DESIGN BASED ON AN EMPIRICAL-MODEL OF PHOTON ATTENUATION
    ARCHER, BR
    THORNBY, JI
    BUSHONG, SC
    [J]. HEALTH PHYSICS, 1983, 44 (05): : 507 - 517
  • [3] ATTENUATION PROPERTIES OF DIAGNOSTIC-X-RAY SHIELDING MATERIALS
    ARCHER, BR
    FEWELL, TR
    CONWAY, BJ
    QUINN, PW
    [J]. MEDICAL PHYSICS, 1994, 21 (09) : 1499 - 1507
  • [4] Bouniol P, 2001, BN3740, V1
  • [5] Evaluation of X-ray spectra transmitted by different concrete compositions
    Costa, P. R.
    Vieira, D. V.
    Naccache, V. K.
    Ferreira, K. R.
    Priszkulnik, S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 349 - 354
  • [6] Hideki K, 2003, JAPN J RADIOL TECH, V59
  • [7] International Commission on Radiological Protection (ICRP), 1996, ANN ICRP, V26
  • [8] Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities
    Kharrati, Hedi
    Agrebi, Amel
    Karaoui, Mohamed-Karim
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1398 - 1404
  • [9] NCRP, 1976, 49 NCRP
  • [10] NCRP, 2008, 147 NCRP