An experimental study on the digital precision of internal fixation via the sinus tarsi approach for calcaneal fractures

被引:5
|
作者
Xu, Jing [1 ]
He, Zaopeng [2 ]
Zhang, Guodong [3 ]
Chen, Yongshao [4 ]
Wei, Chunrong [2 ]
Zheng, Yudong [2 ]
Lin, Haibin [3 ]
Li, Wei [2 ]
Huang, Wenhua [1 ]
机构
[1] Southern Med Univ, Sch Basic Med Sci, Natl Key Discipline Human Anat, 1838 Guangzhou Rd North, Guangzhou 510515, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Affiliated Shunde Hosp, Hand & Foot Surg & Plast Surg, A163,Middle Rd, Foshan 528315, Gudong Province, Peoples R China
[3] Putian Univ, Affiliated Hosp, Dept Orthoped, Putian City, Peoples R China
[4] Guangzhou Med Univ, Affiliated Shunde Hosp, Foshan, Peoples R China
基金
国家重点研发计划;
关键词
Calcaneal fracture; internal fixation; locking bone plate; 3-D printing; navigation; EXTENSILE LATERAL APPROACH; DISPLACED INTRAARTICULAR FRACTURES; SUSTENTACULUM-TALI; ANATOMICAL PLATE; PLACEMENT; SCREWS; METAANALYSIS; MANAGEMENT; TEMPLATES;
D O I
10.1177/2309499019834072
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To investigate the effectiveness and accuracy of internal fixation of calcaneal fractures with a three-dimensional (3-D) printing navigation module via the sinus approach. Methods: Eleven lateral lower extremity specimens were used in the experiment and divided into the digital design (DD) group (n = 11) and the real surgery (RS) group (n = 11). For the DD group, thin-section computed tomography (CT) scans, virtual fracture modeling, virtual bone plate fixation, sinus occlusal module design, and navigation module design were performed for the cadaver specimens. A 3-D navigation module was printed using a 3-D printer. For the RS group, the sinus approach incision was made, and the navigation module was used to assist the placement of screw fixation and anatomically locked bone plate fixation. Thin-layer CT scans, 3-D reconstructions, and reconstruction of the nail paths were performed in the RS group and 3-D registered with the DD group. 3-D coordinate values for the screw entry and exit points in the RS and DD groups were recorded, and the corresponding offset values of the screw points were calculated. The number of qualified nails at different accuracy levels was counted. The chi(2) test was used to compare the data for the DD and RS groups to obtain the accuracy level for both groups when p > 0.05, which is the critical value for experimental accuracy. Results: A total of 11 bone plates were placed and 120 screws were locked. None of them protruded from the inferior articular surface. The screw entry and exit point offsets were 1.71 +/- 0.11 mm and 3.10 +/- 0.19 mm, respectively. When the accuracy requirement for the entry point was 3.8 mm, there was no statistically significant difference between the two groups (p > 0.05). Similarly, the accuracy of the exit point of the screw could only reach 6.6 mm. Conclusion: Internal fixation of calcaneal fractures via the sinus tarsi approach with an anatomical locking plate based on the 3-D printing navigation module can achieve accurate screw placement and good overall internal fixation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Sinus Tarsi Approach with Screws-Only Fixation for Displaced Intra-Articular Calcaneal Fractures
    Schepers, Tim
    CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2019, 36 (02) : 211 - +
  • [2] Sinus Tarsi Approach for Calcaneal Fractures The New Gold Standard?
    Khazen, Gabriel
    Rassi, Cesar Khazen
    FOOT AND ANKLE CLINICS, 2020, 25 (04) : 667 - +
  • [3] Comparison between Percutaneous Screw Fixation and Plate Fixation via Sinus Tarsi Approach for Calcaneal Fractures: An 8-10-Year Follow-up Study
    Weng, Qi-hao
    Dai, Gao-le
    Tu, Qi-ming
    Liu, Yang
    Lutchooman, Vinesh
    Hong, Jian-jun
    Yu, Yang
    ORTHOPAEDIC SURGERY, 2020, 12 (01) : 124 - 132
  • [4] Minimally invasive (sinus tarsi) approach for calcaneal fractures
    Wang, Zhe
    Wang, Xiu Hui
    Li, Sheng Long
    Tang, Xin
    Fu, Bei Gang
    Wang, Ming Hui
    Xia, Sheng Li
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
  • [5] Surgical Treatment of Sanders Type 2 Calcaneal Fractures Using a Sinus Tarsi Approach
    Park, Chul Hyun
    Lee, Dong Yeol
    INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (04) : 461 - 467
  • [6] A windows technique for sustentaculum tali screw fixation using the sinus tarsi approach for calcaneal fractures: a cadaveric study
    Mat Rodi, Mohd Saiful
    Vaseenon, Tanawat
    Phanphaisarn, Areerak
    Hayadin, Noor Mahazrinna
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 637 - 643
  • [7] Minimally Invasive Sinus Tarsi Approach for Open Reduction and Internal Fixation of Calcaneal Fractures: Complications, Risk Factors, and Outcome Predictors
    Alajmi, Turki
    Sharif, Asmaa F.
    Majoun, Majd A.
    Alshehri, Fedaa S.
    Albaqami, Alanood M.
    Alshouli, Mohammed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (01)
  • [8] Sinus Tarsi Approach With Percutaneous Screw Fixation for Intra-Articular Calcaneal Fractures
    Xu, Hao
    Ju, Jihui
    Hou, Ruixing
    Liu, Yuefei
    Zhou, Rong
    Chen, Lucheng
    Hu, Changqing
    Yang, Liang
    JOURNAL OF FOOT & ANKLE SURGERY, 2022, 61 (04) : 792 - 797
  • [9] Role of Subtalar Arthroscopy in Operative Treatment of Sanders Type 2 Calcaneal Fractures Using a Sinus Tarsi Approach
    Park, Chul Hyun
    Yoon, Doo Hyung
    FOOT & ANKLE INTERNATIONAL, 2018, 39 (04) : 443 - 449
  • [10] A windows technique for sustentaculum tali screw fixation using the sinus tarsi approach for calcaneal fractures: a cadaveric study
    Mohd Saiful Mat Rodi
    Tanawat Vaseenon
    Areerak Phanphaisarn
    Noor Mahazrinna Hayadin
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 637 - 643