Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients

被引:83
作者
Cheung, LP [1 ]
Li, KCP [1 ]
Hollett, MD [1 ]
Bergman, AG [1 ]
Herfkens, RJ [1 ]
机构
[1] STANFORD UNIV,CTR MED,DEPT DIAGNOST RADIOL,STANFORD,CA 94305
关键词
knee; abnormalities; ligaments; menisci; and cartilage; MR; magnetic resonance (MR); pulse sequences;
D O I
10.1148/radiology.203.2.9114113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the accuracy of a magnetic resonance (MR) imaging strategy that uses primarily fast spin-echo (SE) sequences for the diagnosis of meniscal tears. MATERIALS AND METHODS: The original clinical interpretations of MR images in 293 patients who underwent imaging for suspected internal derangement of a knee joint were correlated with results from subsequent arthroscopy. MR examination included a double-echo fast SE sequence as the only imaging in the sagittal plane. RESULTS: The sensitivity and specificity for 143 confirmed tears of the medial meniscus were 89% and 84%, respectively, while the values for 96 confirmed tears of the lateral meniscus were 72% and 93%. These values are within the ranges of values recently reported for imaging strategies relying predominantly on conventional SE sequences. CONCLUSION: Fast SE imaging of the knee can be an alternative to conventional SE imaging for the detection of meniscal tears.
引用
收藏
页码:508 / 512
页数:5
相关论文
共 27 条
[1]   EVALUATION OF MENISCAL TEARS - FAST SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO MAGNETIC-RESONANCE-IMAGING [J].
ANDERSON, MW ;
RAGHAVAN, N ;
SEIDENWURM, DJ ;
GREENSPAN, A ;
DRAKE, C .
ACADEMIC RADIOLOGY, 1995, 2 (03) :209-214
[2]   MR DIAGNOSIS OF MENISCAL TEARS OF THE KNEE - VALUE OF AXIAL 3-DIMENSIONAL FOURIER TRANSFORMATION GRASS IMAGES [J].
ARAKI, Y ;
OOTANI, F ;
TSUKAGUCHI, I ;
OOTANI, M ;
FURUKAWA, T ;
YAMAMOTO, T ;
TOMODA, K ;
MITOMO, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (03) :587-590
[3]   MR KNEE IMAGING - AXIAL 3DFT GRASS PULSE SEQUENCE VERSUS SPIN-ECHO IMAGING FOR DETECTING MENISCAL TEARS [J].
AUBEL, S ;
HEYD, RL ;
THAETE, FL ;
WOZNEY, P .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :531-539
[4]   MR DIAGNOSIS OF INTERNAL DERANGEMENTS OF THE KNEE - EFFECT OF FIELD-STRENGTH ON EFFICACY [J].
BARNETT, MJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) :115-118
[5]  
Bonamo J J, 1994, Magn Reson Imaging Clin N Am, V2, P481
[6]   SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING [J].
CONSTABLE, RT ;
SMITH, RC ;
GORE, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :41-47
[7]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[8]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[9]   MENISCAL TEARS OF THE KNEE - ACCURACY OF MR IMAGING [J].
CRUES, JV ;
MINK, J ;
LEVY, TL ;
LOTYSCH, M ;
STOLLER, DW .
RADIOLOGY, 1987, 164 (02) :445-448
[10]   DIAGNOSIS OF MENISCAL TEARS OF THE KNEE WITH MR IMAGING - EFFECT OF OBSERVER VARIATION AND SAMPLE-SIZE ON SENSITIVITY AND SPECIFICITY [J].
DESMET, AA ;
NORRIS, MA ;
YANDOW, DR ;
GRAF, BK ;
KEENE, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :555-559