A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

被引:80
作者
Bennett, D. A. [1 ,2 ]
Horansky, R. D. [1 ,2 ]
Schmidt, D. R. [1 ,3 ]
Hoover, A. S. [4 ]
Winkler, R. [4 ]
Alpert, B. K. [1 ]
Beall, J. A. [1 ]
Doriese, W. B. [1 ,3 ]
Fowler, J. W. [1 ,3 ]
Fitzgerald, C. P. [1 ]
Hilton, G. C. [1 ]
Irwin, K. D. [1 ]
Kotsubo, V. [1 ,3 ]
Mates, J. A. B. [1 ,3 ]
O'Neil, G. C. [1 ]
Rabin, M. W. [4 ]
Reintsema, C. D. [1 ]
Schima, F. J. [1 ]
Swetz, D. S. [1 ]
Vale, L. R. [1 ]
Ullom, J. N. [1 ]
机构
[1] NIST, Boulder, CO 80305 USA
[2] Univ Denver, Denver, CO 80208 USA
[3] Univ Colorado, Boulder, CO 80309 USA
[4] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
TRANSITION-EDGE SENSORS; ENERGY-RESOLUTION; X-RAY; DETECTORS; ARRAYS; SPECTROSCOPY; NOISE;
D O I
10.1063/1.4754630
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gammaray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the non-destructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm(2). We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4754630]
引用
收藏
页数:14
相关论文
共 28 条
  • [1] Predicted Energy Resolution of a Running-Sum Algorithm for Microcalorimeters
    Alpert, Bradley K.
    Doriese, W. Bertrand
    Fowler, Joseph W.
    Ullom, Joel N.
    [J]. JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (5-6) : 582 - 587
  • [2] [Anonymous], J LOW TEMP PHYS
  • [3] Large-Area Microcalorimeter Detectors for Ultra-High-Resolution X-Ray and Gamma-Ray Spectroscopy
    Bacrania, M. K.
    Hoover, A. S.
    Karpius, P. J.
    Rabin, M. W.
    Rudy, C. R.
    Vo, D. T.
    Beall, J. A.
    Bennett, D. A.
    Doriese, W. B.
    Hilton, G. C.
    Horansky, R. D.
    Irwin, K. D.
    Jethava, N.
    Sassi, E.
    Ullom, J. N.
    Vale, L. R.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (04) : 2299 - 2302
  • [4] An analytical model for pulse shape and electrothermal stability in two-body transition-edge sensor microcalorimeters
    Bennett, D. A.
    Horansky, R. D.
    Hoover, A. S.
    Hoteling, N. J.
    Rabin, M. W.
    Schmidt, D. R.
    Swetz, D. S.
    Vale, L. R.
    Ullom, J. N.
    [J]. APPLIED PHYSICS LETTERS, 2010, 97 (10)
  • [5] 14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV
    Doriese, W. B.
    Ullom, J. N.
    Beall, J. A.
    Duncan, W. D.
    Ferreira, L.
    Hilton, G. C.
    Horansky, R. D.
    Irwin, K. D.
    Mates, J. A. B.
    Reintsema, C. D.
    Vale, L. R.
    Xu, Y.
    Zink, B. L.
    Rabin, M. W.
    Hoover, A. S.
    Rudy, C. R.
    Vo, D. T.
    [J]. APPLIED PHYSICS LETTERS, 2007, 90 (19)
  • [6] Progress toward kilopixel arrays: 3.8 eV microcalorimeter resolution in 8-channel SQUID multiplexer
    Doriese, WB
    Beall, JA
    Duncan, WD
    Ferreira, L
    Hilton, GC
    Irwin, KD
    Reintsema, CD
    Ullom, JN
    Vale, LR
    Xu, Y
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02) : 808 - 810
  • [7] Molecular Beam Epitaxially Grown HgTe and HgCdTe-on-Silicon for Space-Based X-Ray Calorimetry Applications
    Dreiske, P.
    Carmody, M.
    Grein, C. H.
    Zhao, J.
    Bommena, R.
    Kilbourne, C. A.
    Kelley, R.
    McCammon, D.
    Brandl, D.
    [J]. JOURNAL OF ELECTRONIC MATERIALS, 2010, 39 (07) : 1087 - 1096
  • [8] SCUBA-2: A large format submillimetre camera on the James Clerk maxwell telescope
    Holland, WS
    Duncan, WD
    Kelly, BD
    Irwin, KD
    Walton, AJ
    Ade, PAR
    Robson, EI
    [J]. MILLIMETER AND SUBMILLIMETER DETECTORS FOR ASTRONOMY, 2003, 4855 : 1 - 18
  • [9] Large microcalorimeter arrays for high-resolution X- and gamma-ray spectroscopy
    Hoover, A. S.
    Hoteling, N.
    Rabin, M. W.
    Ullom, J. N.
    Bennett, D. A.
    Karpius, P. J.
    Vo, D. T.
    Doriese, W. B.
    Hilton, G. C.
    Horansky, R. D.
    Irwin, K. D.
    Kotsubo, V.
    Lee, D. W.
    Vale, L. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01) : 302 - 305
  • [10] Microcalorimeter arrays for ultra-high energy resolution X- and gamma-ray detection
    Hoover, A. S.
    Bacrania, M. K.
    Hoteling, N. J.
    Karpius, P. J.
    Rabin, M. W.
    Rudy, C. R.
    Vo, D. T.
    Beall, J. A.
    Bennett, D. A.
    Doriese, W. B.
    Hilton, G. C.
    Horansky, R. D.
    Irwin, K. D.
    Ullom, J. N.
    Vale, L. R.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (01) : 227 - 232