RETRACTED: Accuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid (Retracted Article)

被引:21
作者
Bergek, Christian [1 ]
Zdolsek, Joachim H. [1 ]
Hahn, Robert G. [1 ]
机构
[1] Linkoping Univ, Fac Hlth Sci, Sect Anaesthesia, Linkoping, Sweden
关键词
colloid; crystalloid; haemoglobin; pulse oximetry; SPINAL-ANESTHESIA; VOLUME EXPANSION; BLOOD HEMOGLOBIN; RINGERS SOLUTION; KINETICS; SURGERY; PLASMA;
D O I
10.1097/EJA.0b013e3283592733
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Context Measurement of blood haemoglobin concentration by pulse oximetry could be of value in determining when erythrocytes should be transfused during surgery, but the effect of infusion fluids on the results is unclear. Objective To study the effect of crystalloid and colloid fluid on the accuracy (bias) and precision of pulse oximetry haemoglobin estimation to indicate the venous haemoglobin concentration in volunteers. Design Open interventional crossover study. Setting Single university hospital. Participants Ten male volunteers aged 18-28 (mean 22) years. Interventions Each volunteer underwent three infusion experiments on separate days and in random order. The infusions were Ringer's acetate (20 ml kg(-1)), hydroxyethyl starch 130/0.4 (10 ml kg(-1)) and a combination of both. Results At the end of the infusions of Ringer's acetate, pulse oximetry haemoglobin concentration had decreased more than the true haemoglobin concentration (15 vs. 8%; P < 0.005; n = 10) whereas starch solution decreased pulse oximetry haemoglobin concentration less than true haemoglobin concentration (7 vs. 11%; P < 0.02; n 20). The same differences were seen when the fluids were infused separately and when they were combined. The overall difference between all 956 pairs of pulse oximetry haemoglobin concentration and true haemoglobin concentrations (the bias) averaged only -0.7 g l(-1) whereas the 95% prediction interval was wide, ranging from -24.9 to 23.7 g l(-1). In addition to the choice of infusion fluid, the bias was strongly dependent on the volunteer (each factor, P < 0.001). Conclusion The bias of measuring haemoglobin concentration by pulse oximetry is dependent on whether a crystalloid or a colloid fluid is infused. Trial registration ClinicalTrials identifier: NCT01195025. Eur J Anaesthesiol 2012; 29: 586-592 Published online 8 October 2012
引用
收藏
页码:586 / 592
页数:7
相关论文
共 20 条
[1]   The Accuracy of Noninvasive Hemoglobin Measurement by Multiwavelength Pulse Oximetry After Cardiac Surgery [J].
Ba-Vinh Nguyen ;
Vincent, Jean-Louis ;
Nowak, Emmanuel ;
Coat, Michelle ;
Paleiron, Nicolas ;
Gouny, Pierre ;
Ould-Ahmed, Mehdi ;
Guillouet, Maite ;
Arvieux, Charles Christian ;
Gueret, Gildas .
ANESTHESIA AND ANALGESIA, 2011, 113 (05) :1052-1057
[2]   Continuous Noninvasive Hemoglobin Monitoring During Complex Spine Surgery [J].
Berkow, Lauren ;
Rotolo, Stephanie ;
Mirski, Erin .
ANESTHESIA AND ANALGESIA, 2011, 113 (06) :1396-1402
[3]   Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station [J].
Causey, Marlin Wayne ;
Miller, Seth ;
Foster, Andrew ;
Beekley, Alec ;
Zenger, David ;
Martin, Matthew .
AMERICAN JOURNAL OF SURGERY, 2011, 201 (05) :590-596
[4]   Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin [J].
Colquhoun, Douglas A. ;
Forkin, Katherine T. ;
Durieux, Marcel E. ;
Thiele, Robert H. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) :69-73
[5]   Kinetics of isotonic and hypertonic plasma volume expanders [J].
Drobin, D ;
Hahn, RG .
ANESTHESIOLOGY, 2002, 96 (06) :1371-1380
[6]   Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients [J].
Frasca, Denis ;
Dahyot-Fizelier, Claire ;
Catherine, Karen ;
Levrat, Quentin ;
Debaene, Bertrand ;
Mimoz, Olivier .
CRITICAL CARE MEDICINE, 2011, 39 (10) :2277-2282
[7]   Performance Evaluation of a Noninvasive Hemoglobin Monitoring Device [J].
Gayat, Etienne ;
Bodin, Antoine ;
Sportiello, Caroline ;
Boisson, Mireille ;
Dreyfus, Jean-Francois ;
Mathieu, Emmanuel ;
Fischler, Marc .
ANNALS OF EMERGENCY MEDICINE, 2011, 57 (04) :330-333
[8]   Volume kinetics of acetated Ringer's solution during experimental spinal anaesthesia [J].
Hahn, R. G. ;
Lindahl, C. C. ;
Drobin, D. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (08) :987-994
[9]   Non-invasive monitoring of blood haemoglobin for analysis of fluid volume kinetics [J].
Hahn, R. G. ;
Li, Y. ;
Zdolsek, J. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (10) :1233-1240
[10]   Volume expansion and plasma protein clearance during intravenous infusion of 5% albumin and autologous plasma [J].
Hedin, A ;
Hahn, RG .
CLINICAL SCIENCE, 2005, 108 (03) :217-224