Study of non-linear energy response of POLAR plastic scintillators to electrons

被引:7
作者
Zhang, Xiaofeng [1 ,3 ]
Xiao, Hualin [1 ]
Yu, Boxiang [2 ]
Orsi, Silvio [4 ,5 ]
Wu, Bobing [1 ]
Hu, Wei [2 ,3 ]
Zhang, Xuan [2 ,3 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing 100049, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Univ Genoa, DPNC, CH-1205 Geneva, Switzerland
[5] CAP, Geneva, Switzerland
关键词
POLAR; Non-linear energy response; Coincidence; Least squares; Monte Carlo simulation; Birks' constant; GAMMA-RAY BURSTS; POLARIZATION; EMISSION; DETECTOR; SPECTRA;
D O I
10.1016/j.nima.2015.06.031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The POLAR experiment is a joint Chinese-European project conceived for a precise measurement of gamma ray polarization and optimized for the detection of the prompt emission of Gamma-Ray Bursts (GRBs) in the energy range 50-500 keV. POLAR is a novel compact space-borne Compton polarimeter consisting of 1600 low-Z plastic scintillator bars (EJ-248M), read out by 25 flat-panel multi-anode photomultiplier tubes. In the paper, we first present a dedicated experiment to study the non-linear energy response of EJ-248N1 plastic scintillator bars to electrons and the detailed data analysis. Second we obtained the Birks` constant of EJ-248M plastic scintillator as kB = 0.143 mm/NleV by least squares fitting. Filially we used Geant4 simulation to study the influence of non-linear energy response on the performance of POLAR, through which it was found that non-linear energy response will lead to a significant decrease in statistics and result in larger uncertainty in polarization measurement. The paper presents a general solution to the study of non-linear energy response of plastic scintillators to electrons. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 20 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] [Anonymous], 1964, THEORY PRACTICE SCIN
  • [3] ENERGY-SPECTRA OF X-RAY CLUSTERS OF GALAXIES
    AVNI, Y
    [J]. ASTROPHYSICAL JOURNAL, 1976, 210 (03) : 642 - 646
  • [4] NON-LINEAR RESPONSE OF PLASTIC SCINTILLATOR NE102
    BADHWAR, GD
    DENEY, CL
    DENNIS, BR
    KAPLON, MF
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1967, 57 (01): : 116 - &
  • [5] BATSE OBSERVATIONS OF GAMMA-RAY BURST SPECTRA .1. SPECTRAL DIVERSITY
    BAND, D
    MATTESON, J
    FORD, L
    SCHAEFER, B
    PALMER, D
    TEEGARDEN, B
    CLINE, T
    BRIGGS, M
    PACIESAS, W
    PENDLETON, G
    FISHMAN, G
    KOUVELIOTOU, C
    MEEGAN, C
    WILSON, R
    LESTRADE, P
    [J]. ASTROPHYSICAL JOURNAL, 1993, 413 (01) : 281 - 292
  • [6] Testing of photomultiplier tubes for use in the surface detector of the Pierre Auger observatory
    Barnhill, D.
    Suarez, F.
    Arisaka, K.
    Garcia, B.
    Gongora, J. P.
    Lucero, A.
    Navarro, I.
    Ohnukia, T.
    Risi, A.
    Tripathi, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (03) : 453 - 466
  • [7] Polarization of the prompt γ-ray emission from the γ-ray burst of 6 December 2002
    Coburn, W
    Boggs, SE
    [J]. NATURE, 2003, 423 (6938) : 415 - 417
  • [8] ANALYSIS OF RESPONSE DATA FOR SEVERAL ORGANIC SCINTILLATORS
    CRAUN, RL
    SMITH, DL
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 80 (02): : 239 - &
  • [9] Towards a complete theory of gamma-ray bursts
    Dar, A
    De Rújula, A
    [J]. PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 2004, 405 (04): : 203 - 278
  • [10] Wide field compact detector for hard X-ray polarization measurements
    Hajdas, W.
    Produit, N.
    Suarez-Garcia, E.
    Barao, F.
    Casella, C.
    Deiters, K.
    Deluit, S.
    Leluc, C.
    Mchedlishvili, A.
    Pohl, M.
    Rapin, D.
    Tao, Ch.
    Vialle, J. -P.
    Walter, R.
    Wigger, C.
    Zehnder, A.
    [J]. SPACE TELESCOPES AND INSTRUMENTATION II: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2006, 6266