Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer

被引:10
|
作者
Boehnke, Frank [1 ]
Bretan, Theodor [2 ]
Lehner, Stefan [2 ]
Strenger, Tobias [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Otorhinolaryngol Head & Neck Surg, D-81675 Munich, Germany
[2] Munich Univ Appl Sci, Dept Appl Sci & Mechatron, D-80335 Munich, Germany
来源
MATERIALS | 2013年 / 6卷 / 10期
关键词
middle ear; mu CT; Multi-body System (MBS); floating mass transducer (FMT); laser-Doppler vibrometry (LDV); FINITE-ELEMENT-METHOD; BEHAVIOR; MODEL;
D O I
10.3390/ma6104675
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The transfer characteristic of the human middle ear with an applied middle ear implant (floating mass transducer) is examined computationally with a Multi-body System approach and compared with experimental results. For this purpose, the geometry of the middle ear was reconstructed from mu-computer tomography slice data and prepared for a Multi-body System simulation. The transfer function of the floating mass transducer, which is the ratio of the input voltage and the generated force, is derived based on a physical context. The numerical results obtained with the Multi-body System approach are compared with experimental results by Laser Doppler measurements of the stapes footplate velocities of five different specimens. Although slightly differing anatomical structures were used for the calculation and the measurement, a high correspondence with respect to the course of stapes footplate displacement along the frequency was found. Notably, a notch at frequencies just below 1 kHz occurred. Additionally, phase courses of stapes footplate displacements were determined computationally if possible and compared with experimental results. The examinations were undertaken to quantify stapes footplate displacements in the clinical practice of middle ear implants and, also, to develop fitting strategies on a physical basis for hearing impaired patients aided with middle ear implants.
引用
收藏
页码:4675 / 4688
页数:14
相关论文
共 3 条
  • [1] Human middle-ear nonlinearity measurements using laser Doppler vibrometry
    Gladine, Kilian
    Muyshondt, Pieter G. G.
    Dirckx, Joris J. J.
    OPTICS AND LASERS IN ENGINEERING, 2017, 99 : 98 - 102
  • [2] Minimally invasive laser vibrometry (MIVIB) with a floating mass transducer - A new method for objective evaluation of the middle ear demonstrated on stapes fixation
    Wales, Jeremy
    Gladine, Kilian
    Van de Heyning, Paul
    Topsakal, Vedat
    von Unge, Magnus
    Dirckx, Joris
    HEARING RESEARCH, 2018, 357 : 46 - 53
  • [3] Vibration Analysis of Human Middle Ear with Differential Floating Mass Transducer Using Electrical Model
    Seong, Ki-Woong
    Jung, Eui-Sung
    Lim, Hyung-Gyu
    Lee, Jang-Woo
    Kim, Min-Woo
    Woo, San -Hyo
    Lee, Jung-Hyun
    Park, Il-Yong
    Cho, Jin-Ho
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2009, E92D (10): : 2156 - 2158