Transform-based backprojection for volume reconstruction of large format electron microscope tilt series

被引:87
作者
Lawrence, A [1 ]
Bouwer, JC [1 ]
Perkins, G [1 ]
Ellisman, MH [1 ]
机构
[1] Univ Calif San Diego, Natl Ctr Microscopy & Imaging Res, Ctr Res Biol Struct, La Jolla, CA 92093 USA
关键词
electron microscopy; tomography; reconstruction; bundle adjustment; nonlinear projection; radon transform;
D O I
10.1016/j.jsb.2005.12.012
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Alignment of the individual images of a tilt series is a critical step in obtaining high-quality electron microscope reconstructions. We report on general methods for producing good alignments, and utilizing the alignment data in Subsequent reconstruction steps. Our alignment techniques utilize bundle adjustment. Bundle adjustment is the simultaneous calculation of the position of distinguished markers in the object space and the transforms of these markers to their positions in the observed images, along the bundle of particle trajectories along which the object is projected to each EM image. Bundle adjustment techniques are general enough to encompass the Computation of linear, projective or nonlinear transforms for backprojection, and can compensate for curvilinear trajectories through the object, sample warping, and optical aberration, We will also report on new reconstruction codes and describe our results using these codes. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:144 / 167
页数:24
相关论文
共 64 条
[1]  
AGAR AW, 1974, PRINCIPLES PRACTICE
[2]  
AIKENS RS, 1989, METHOD CELL BIOL, V29, P291
[3]  
Anderson E, 1999, LAPACK USERS GUIDE
[4]  
[Anonymous], 2001, SIAM monographs on mathematical modeling and computation
[5]  
ARII T, 1987, J ELECTRON MICROSC, V36, P177
[6]   Estimating alignment errors in sets of 2-D images [J].
Baldwin, PR ;
Penezek, PA .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 150 (02) :211-225
[7]   THE INVERSION PROBLEM AND APPLICATIONS OF THE GENERALIZED RADON-TRANSFORM [J].
BEYLKIN, G .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 1984, 37 (05) :579-599
[8]   Automated most-probable loss tomography of thick selectively stained biological specimens with quantitative measurement of resolution improvement [J].
Bouwer, JC ;
Mackey, MR ;
Lawrence, A ;
Deerinck, TJ ;
Jones, YZ ;
Terada, M ;
Martone, ME ;
Peltier, S ;
Ellisman, MH .
JOURNAL OF STRUCTURAL BIOLOGY, 2004, 148 (03) :297-306
[9]   3D surface reconstruction using occluding contours [J].
Boyer, E ;
Berger, MO .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (03) :219-233
[10]   Automatic alignment of transmission electron microscope tilt series without fiducial markers [J].
Brandt, S ;
Heikkonen, J ;
Engelhardt, P .
JOURNAL OF STRUCTURAL BIOLOGY, 2001, 136 (03) :201-213