The upgrade of the Belle II forward calorimeter

被引:0
|
作者
Manoni, E. [1 ,2 ]
Aloisio, A. [3 ,4 ]
Baccaro, S. [5 ,6 ]
Branchini, P. [7 ]
Cecchi, C. [1 ,2 ]
Cemmi, A. [5 ,6 ]
De Lucia, E. [8 ]
De Nardo, G. [3 ,4 ]
de Sangro, R. [8 ]
Felici, G. [8 ]
Finocchiaro, G. [8 ]
Fiore, S. [3 ]
Giordano, R. [3 ]
Merola, M. [3 ]
Oberhof, B. [8 ]
Passeri, A. [7 ]
Peruzzi, I. M. [8 ]
Piccolo, M. [8 ]
Rossi, A. [9 ]
Sciacca, C. [3 ,4 ]
机构
[1] INFN Perugia, Perugia, Italy
[2] Univ Perugia, Perugia, Italy
[3] INFN Naples, Naples, Italy
[4] Univ Naples Federico II, Naples, Italy
[5] ENEA FSN, Rome, Italy
[6] INFN, Sez Roma, Rome, Italy
[7] INFN Roma3, Rome, Italy
[8] INFN, Lab Nazl Frascati, Frascati, Italy
[9] INFN Perugia, Perugia, Italy
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2017年 / 845卷
关键词
Calorimetry; Photodetectors; Cesium iodide; Belle II;
D O I
10.1016/j.nima.2016.06.074
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The new facility SuperKEKB will be an upgrade of the existing KEKB electron-positron asymmetric collider, with a target luminosity of 8 x 10(35) cm(-2) s(-1), about 40 times greater than that of KEKB. The detector will also be upgraded to cope with the higher luminosity, pile-up and occupancy. We report here on the design and development of the new pure CsI calorimeter for the forward region. An intensive R&D is being carried on to study the performance of pure CsI crystals with Avalanche Photodiodes readout. Results about the relative energy resolution of this detector, along with radiation hardness studies of all the components, are presented. A matrix of 16 crystals has been put on an electron beam at the BTF facility in Frascati and results in terms of energy resolution of this prototype are also discussed. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:524 / 527
页数:4
相关论文
共 50 条
  • [1] Upgrade of the Belle II electromagnetic calorimeter
    Miyabayashi, K.
    Aulchenko, V.
    Cheon, B. G.
    Kuzmin, A. S.
    Matvienko, D.
    Nakamura, I.
    Shebalin, V.
    Shwartz, B.
    Unno, Y.
    Usov, Y.
    Vinokurova, A.
    Zhulanov, V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [2] A Low Noise Front End for the Belle II Forward Electromagnetic Calorimeter Upgrade
    Branchini, P.
    Budano, A.
    Galasso, M.
    Tagnani, D.
    Aloisio, A.
    Corradi, G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (06) : 1409 - 1414
  • [3] Belle calorimeter upgrade
    Shwartz, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 220 - 223
  • [4] The BELLE Electromagnetic Calorimeter and its Upgrade to Bellell
    Cecchi, C.
    Aloisio, A.
    Baccaro, S.
    Branchini, P.
    Cemmi, A.
    De Lucia, E.
    De Nardo, G.
    De Sangro, R.
    Epifanov, D.
    Finocchiaro, G.
    Fiore, S.
    Giordano, R.
    Kuzmin, A. S.
    Manoni, E.
    Merola, M.
    Oberhof, B.
    Passeri, A.
    Peruzzi, I. M.
    Piccolo, M.
    Rossi, A.
    Tagnani, D.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [5] Belle Electromagnetic Calorimeter and its sBelle Upgrade
    Nakamura, Isamu
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [6] Electromagnetic Calorimeter Upgrade for Belle2
    Nakamura, Isamu
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293
  • [7] A FOrward CALorimeter Upgrade For PHENIX
    Hollis, Richard S.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY: TWENTY-FIRST INTERNATIONAL CONFERENCE, 2011, 1336 : 556 - 559
  • [8] A Low Noise Front-end for the Belle2 Forward Electromagnetic Calorimeter Upgrade
    Branchini, P.
    Aloisio, A.
    Budano, A.
    Corradi, G.
    Galasso, M.
    Tagnani, D.
    2016 IEEE-NPSS REAL TIME CONFERENCE (RT), 2016,
  • [9] APD readout for Belle II Endcap Calorimeter Upgrade with Undoped Cesium Iodide Crystals
    Fiore, S.
    Aloisio, A.
    Baccaro, S.
    Branchini, P.
    Cavaliere, S.
    Cecchi, C.
    Cemmi, A.
    Corradi, G.
    De Lucia, E.
    De Nardo, G.
    de Sangro, R.
    Felici, G.
    Finocchiaro, G.
    Giordano, R.
    Lubrano, P.
    Manoni, E.
    Montecchi, M.
    Oberhof, B.
    Ordine, A.
    Passeri, A.
    Patteri, P.
    Peruzzi, I.
    Piccolo, M.
    Rossi, A.
    Sciacca, C.
    Tagnani, D.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [10] Electromagnetic calorimeter for Belle II
    Aulchenkol, V.
    Bobrov, A.
    Bondar, A.
    Cheon, B. G.
    Eidelman, S.
    Epifanov, D.
    Garmash, Yu
    Goh, Y. M.
    Kim, S. H.
    Krokovny, P.
    Kuzmin, A.
    Lee, I. S.
    Matvienko, D.
    Miyabayashi, K.
    Nakamura, I.
    Shebalin, V.
    Shwartz, B.
    Unno, Y.
    Usov, Yu
    Vinokurova, A.
    Vorobjev, V.
    Zhilich, V.
    Zhulanov, V.
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587