Double mobility cup total hip arthroplasty in patients at high risk for dislocation: a single-center analysis

被引:12
作者
Kaiser, Dominik [1 ]
Kamath, Atul F. [1 ]
Zingg, Patrick [1 ]
Dora, Claudio [1 ]
机构
[1] Uniklin Balgrist, CH-8008 Zurich, Switzerland
关键词
Double cup mobility system; Dislocation; Total hip arthroplasty; Primary; Revision; Complications; CONSTRAINED ACETABULAR COMPONENTS; FEMORAL-HEAD SIZE; REVISION THA; ROTATOR CUFF; REPLACEMENT; RATES; DEGENERATION; INSTABILITY; SOCKETS; MUSCLES;
D O I
10.1007/s00402-015-2316-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Double mobility cup systems (DMCS) have gained increasing acceptance, especially in patients at high risk for dislocation. The aim of this investigation was to analyze the frequency and indications of the DMCS use in our praxis and to evaluate dislocation and cup revision rates after a minimum follow-up of 2 years. All patients implanted with a DMCS from May 2008 to August 2011 were identified from our institutional database of primary and revision THA procedures. Patient demographics, including ASA score, were recorded, along with details of the surgical procedures, indications for DMCS use, and post-operative clinical course and any complications. Radiographs were analyzed for implant positioning and radiological signs of loosening. 1046 primary THA were implanted, of these 39 (4 %) primary DMCS. Indications were severe neuromuscular disease (SND) (14), hip abductor degeneration (HAD) (9), cognitive dysfunction (CD) (8) and others. 345 revision THA were performed, of these 50 (14 %) revision DMCS. Indications were recurrent dislocations (27), multiple prior hip surgeries (13), HAD (5), CD (3) and others. Overall dislocation rate was 2/89 (2 %); both in revision THA. Overall cup revision rate was 5/89 (6 %): 3 septic, 1 periprosthetic acetabular fracture, 1 "intraprosthetic dissociation". 67 patients were available for the standardized questionnaire at a median follow-up of 43 months (range 25-78). 19 patients were not available for two-year follow-up: 17 died and two were lost to follow-up. This study supports the use of DMCS constructs in primary and revision hip arthroplasty for specific high-risk patients. We continue to indicate DMCS in this patient group. We do caution against extending indications for DMCS to lower risk patient groups due to unknown issues surrounding wear and component longevity.
引用
收藏
页码:1755 / 1762
页数:8
相关论文
共 42 条
[1]   Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[2]  
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[3]  
[Anonymous], 2013, NAT AUSTR JOINT HIP
[4]   The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty - Examining the successes and failures [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Adams, JB ;
Russell, JH ;
Groseth, KL .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :93-102
[5]   The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :9-14
[6]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]   5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets -: Two randomized studies using radiostereometric analysis [J].
Digas, Georgios ;
Karrholm, Johan ;
Thanner, Jonas ;
Herberts, Peter .
ACTA ORTHOPAEDICA, 2007, 78 (06) :746-754
[8]  
EKELUND A, 1992, CLIN ORTHOP RELAT R, P101
[9]  
FACKLER CD, 1980, CLIN ORTHOP RELAT R, P169
[10]   Fatty degeneration of the muscles of the rotator cuff: Assessment by computed tomography versus magnetic resonance imaging [J].
Fuchs, B ;
Weishaupt, D ;
Zanetti, M ;
Hodler, J ;
Gerber, C .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1999, 8 (06) :599-605