A pixel chamber to monitor the beam performances in hadron therapy

被引:15
作者
Bonin, R
Boriano, A
Bourhaleb, F
Cirio, R
Donetti, M
Garelli, E
Giordanengo, S
Marchetto, F
Peroni, C
Freire, CJS
Simonetti, L
机构
[1] Univ Turin, Dipartimento Fis Sperimentale, I-10125 Turin, Italy
[2] Ist Nazl Fis Nucl, I-10125 Turin, Italy
[3] Fdn TERA, I-28100 Novara, Italy
[4] ASP, I-10125 Turin, Italy
关键词
radiotherapy; beam monitor; ionization chamber; dosimetry; carbon ion;
D O I
10.1016/j.nima.2003.11.104
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper we describe the design, construction, and tests of a parallel plate ionization chamber with the anode segmented in (32 x 32) square pixels. The performance of the read out and data acquisition systems is also discussed. The design of the chamber has been finalized to be used as a beam monitor for therapeutical treatments. Position and flux resolution obtained with a carbon ion beam are presented. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:674 / 686
页数:13
相关论文
共 8 条
[1]  
Belletti S, 1999, PHYS MEDICA, V15, P137
[2]  
Belletti S, 2001, PHYS MEDICA, V17, P49
[3]   Pixel segmented ionization chamber for therapeutical beams of photons and hadrons [J].
Belletti, S ;
Cirio, R ;
Cocuzza, L ;
Degiorgis, PG ;
Donetti, M ;
Madon, E ;
Marcherto, F ;
Marletti, M ;
Marzoli, L ;
Peroni, C ;
Trevisiol, E ;
Urgesi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3) :420-421
[4]   Performances of a VLSI wide dynamic range current-to-frequency converter for strip ionization chambers [J].
Bonazzola, GC ;
Cirio, R ;
Donetti, M ;
Marchetto, F ;
Mazza, G ;
Peroni, C ;
Zampieri, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 405 (01) :111-120
[5]   A dosimetry system for fast measurement of 3D depth-dose profiles in charged-particle tumor therapy with scanning techniques [J].
Brusasco, C ;
Voss, B ;
Schardt, D ;
Krämer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 168 (04) :578-592
[6]   Tumor therapy with heavy charged particles [J].
Kraft, G .
PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, VOL 45, SUPPLEMENT 2, 2000, 45 :S473-S544
[7]   Treatment planning for heavy-ion radiotherapy:: Biological optimization of multiple beam ports [J].
Krämer, M .
JOURNAL OF RADIATION RESEARCH, 2001, 42 (01) :39-46
[8]   Depth scanning for a conformal ion beam treatment of deep seated tumours [J].
Weber, U ;
Becher, W ;
Kraft, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3627-3641