Detection of tricyclic antidepressants in whole blood by headspace solid-phase microextraction and capillary gas chromatography

被引:65
作者
Lee, XP
Kumazawa, T
Sato, K
Suzuki, O
机构
[1] SHOWA UNIV, SCH MED, DEPT LEGAL MED, SHINAGAWA KU, TOKYO 142, JAPAN
[2] HAMAMATSU UNIV SCH MED, DEPT LEGAL MED, HAMAMATSU, SHIZUOKA 43131, JAPAN
关键词
D O I
10.1093/chromsci/35.7.302
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method for the extraction of four tricyclic antidepressants from whole blood by headspace solid-phase microextraction (SPME) is presented. The whole blood samples contain four drugs (amitriptyline, chlorimipramine, imipramine, and trimipramine) and are heated at 100°C in a septum-capped vial in the presence of distilled water and NaOH solution; a polydimethylsiloxane-coated SPME fiber is exposed to the headspace of the vial to allow adsorption of the drugs before capillary gas chromatography (GC) with flame-ionization detection. The headspace SPME-GC produces intense peaks for each drug with very little background noise. Recoveries of the four drugs by the present method are 5.3-12.9%. The calibration curves for the drugs show linearity in the range of 31-1000 ng/0.5 ml. The detection limits of each drug are 16-25 ng/0.5 mL. Imipramine is detectable from rat blood 5 h after oral administration of imipramine (500 mg/kg body weight); the concentration is 1.44 ± 0.209 μg/mL.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 20 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]  
CHRISTMORE DS, 1984, J FORENSIC SCI, V29, P1038
[3]   NEW SENSITIVE AND SELECTIVE DETECTOR FOR GAS-CHROMATOGRAPHY - SURFACE-IONIZATION DETECTOR WITH A HOT PLATINUM EMITTER [J].
FUJII, T ;
ARIMOTO, H .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2625-2628
[4]   SENSITIVE DETERMINATION OF PHENOTHIAZINES IN BODY-FLUIDS BY GAS-CHROMATOGRAPHY WITH SURFACE-IONIZATION DETECTION [J].
HATTORI, H ;
YAMAMOTO, S ;
IWATA, M ;
TAKASHIMA, E ;
YAMADA, T ;
SUZUKI, O .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 579 (02) :247-252
[5]   COMPONENTS OF PAINT THINNER IN BODY-FLUIDS CLEARLY DETECTED USING THE SALTING-OUT TECHNIQUE [J].
KATO, K ;
NAGATA, T ;
KIMURA, K ;
KUDO, K ;
IMAMURA, T ;
NODA, M .
FORENSIC SCIENCE INTERNATIONAL, 1990, 44 (01) :55-60
[6]   Detection of ethanol in human body fluids by headspace solid-phase micro extraction (SPME) capillary gas chromatography [J].
Kumazawa, T ;
Seno, H ;
Lee, XP ;
Ishii, A ;
Suzuki, O ;
Sato, K .
CHROMATOGRAPHIA, 1996, 43 (7-8) :393-397
[7]   Extraction of local anaesthetics from human blood by direct immersion solid phase micro extraction (SPME) [J].
Kumazawa, T ;
Sato, K ;
Seno, H ;
Ishii, A ;
Suzuki, O .
CHROMATOGRAPHIA, 1996, 43 (1-2) :59-62
[8]  
Kumazawa T., 1995, JPN J FORENSIC TOXIC, V13, P207
[9]   A SIMPLE ANALYSIS OF 5 THINNER COMPONENTS IN HUMAN-BODY FLUIDS BY HEADSPACE SOLID-PHASE MICROEXTRACTION (SPME) [J].
LEE, XP ;
KUMAZAWA, T ;
SATO, K .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 1995, 107 (06) :310-313
[10]   Detection of organophosphate pesticides in human body fluids by headspace solid-phase microextraction (SPME) and capillary gas chromatography with nitrogen-phosphorus detection [J].
Lee, XP ;
Kumazawa, T ;
Sato, K ;
Suzuki, O .
CHROMATOGRAPHIA, 1996, 42 (3-4) :135-140