摘要
This paper presents a new approach to solve line outage detection (LOD) problem utilizing current phasors obtained from phasor measurement units (PMUs). A new term that is, objective coefficient value (OCV), is introduced utilizing the rank correlation coefficient (RCC) and line outage detection is carried out based on the OCV. Moreover, the effect of bad data (BD) and measurement noises are also considered in the developed mathematical model. Furthermore, it has been proved that the suggested scheme can identify outage of parallel lines (PLs), whereas the existing voltage phasor-based algorithms fail to do so. Moreover, a new logical index that is, performance improvement w.r.t detection accuracy (PIDA) is introduced to quantify the superiority of the proposed scheme over some existing techniques. The developed algorithm is implemented on IEEE 5-bus, 14-bus, 57-bus, 118-bus systems, and large-scale Polish 2383-bus system. The comparison of test results with some existing methods proves the applicability and brevity of the developed algorithm.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Line Outage Detection Using Phasor Measurement Units
    Srikumar, M. S.
    Ananthapadmanbha, T.
    Khan, Faraz Zafar
    Girish, V
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 88 - 95
  • [2] Line Outage Detection Using Phasor Angle Measurements
    Tate, Joseph Euzebe
    Overbye, Thomas J.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (04) : 1644 - 1652
  • [3] Double Line Outage Detection Using Phasor Angle Measurements
    Tate, Joseph Euzebe
    Overbye, Thomas J.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 3277 - +
  • [4] Line outage detection using optimal number of Phasor Measurement Unit
    Kumar, Hemant
    Dahiya, Ratna
    2019 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2019,
  • [5] PMU based line outage identification using comparison of current phasor measurement technique
    Alam, Mehebub
    Kundu, Shubhrajyoti
    Thakur, Siddhartha Sankar
    Banerjee, Sumit
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 115
  • [6] Robust Power Line Outage Detection with Unreliable Phasor Measurements
    Cordova-Garcia, Jose
    Wang, Xin
    2017 IEEE 33RD INTERNATIONAL CONFERENCE ON DATA ENGINEERING (ICDE 2017), 2017, : 1309 - 1319
  • [7] Effects of Phasor Measurement Uncertainty on Power Line Outage Detection
    Chen, Chen
    Wang, Jianhui
    Zhu, Hao
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2014, 8 (06) : 1127 - 1139
  • [8] A new cost effective algorithm for online identification of line outage contingency using current phasor of PMU
    Alam, Mehebub
    Kundu, Shubhrajyoti
    Thakur, Siddhartha Sankar
    Banerjee, Sumit
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2020, 23
  • [9] External System Line Outage Identification Using Phasor Measurement Units
    Emami, Roozbeh
    Abur, Ali
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (02) : 1035 - 1040
  • [10] Line Outage Localization Using Phasor Measurement Data in Transient State
    Garcia, Manuel
    Catanach, Thomas
    Wiel, Scott Vander
    Bent, Russell
    Lawrence, Earl
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (04) : 3019 - 3027