In Vitro Evaluation of the Primary Stability of Short and Conventional Implants

被引:10
作者
Pimentel Lopes de Oliveira, Guilherme Jose [1 ]
Borelli Barros-Filho, Luiz Antonio [1 ]
Borelli Barros, Luiz Antonio [2 ]
Queiroz, Thalita Pereira [3 ]
Marcantonio, Elcio, Jr. [1 ]
机构
[1] Araraquara Univ Estadual Paulista, Sch Dent, Dept Diag & Surg, Sect Periodontol, Araraquara, SP, Brazil
[2] Araraquara Univ Estadual Paulista, Sch Dent, Dept Oral Social Hlth, Sect Clin, Araraquara, SP, Brazil
[3] Univ Ctr Araraquara Araraquara, Sch Dent, Dept Hlth Sci, Sao Paulo, Brazil
关键词
bone density; short implants; osseointegration; SHORT DENTAL IMPLANTS; RESONANCE-FREQUENCY; INSERTION TORQUE; SURVIVAL RATE; SINUS FLOOR; MULTICENTER; PROSTHESES; DIAMETER; STANDARD; OUTCOMES;
D O I
10.1563/aaid-joi-D-16-00094
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this study was to evaluate the primary stability of short and conventional dental implants with different platform types at different site densities in vitro. One hundred twenty implants were placed in polyurethane blocks that simulate different bone densities (bone types I and IV). The implants were divided into 10 groups, with 12 implants each according to the type of prosthetic connections (external hexagon, EH; morse taper, MT) and size of the implants (conventional: 4 x 10 mm; short: 5 x 5, 5.5 x 5, 5 x 6, and 5.5 x 6 mm). Insertion torque and resonance frequency analyses were performed to evaluate the primary stability. The Kruskal-Wallis test complemented by Dunn's test and the Mann-Whitney test were used for statistical analysis. These tests were applied at the confidence level of 95% (P<.05). The implants installed in blocks with density type IV exhibited reduced insertion torque compared with implants placed in blocks with density type I. Short implants with EH exhibited increased insertion torque compared with short implants with MT in blocks with bone density type I. In general, implants installed in blocks with density type I exhibited greater primary stability. The short implants with EH with a 5.5-mm diameter and the short implants with MT with a 5-mm diameter exhibited reduced primary stability. No differences between short and conventional implants were noted. Short implants have primary stability and insertion torque at least equivalent to conventional implants irrespective of the platform type and density of the site.
引用
收藏
页码:458 / 463
页数:6
相关论文
共 29 条
  • [1] Al-Quran FA, 2011, BMC ORAL HEALTH, V21, P11
  • [2] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [3] Analysis of Short Implants and Lateralization of the Inferior Alveolar Nerve With 2-Stage Dental Implants by Finite Element Method
    Amorim Vasco, Marco Antonio
    Hecke, Mildred Ballin
    Bezzon, Osvaldo Luiz
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) : 2064 - 2071
  • [4] Anitua E, 2008, J PERIODONTOL, V79, P42, DOI [10.1902/jop.2008.070142, 10.1902/jop.2008.070142 ]
  • [5] Arlin ML, 2006, INT J ORAL MAX IMPL, V21, P769
  • [6] Barewal RM, 2012, INT J ORAL MAX IMPL, V27, P945
  • [7] Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study
    Bilhan, Hakan
    Bilmenoglu, Caglar
    Urgun, Aliye Ceren
    Ates, Gokcen
    Bural, Canan
    Cilingir, Altug
    Geckili, Onur
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (05) : 1036 - 1040
  • [8] Implant stability measurement of delayed and immediately loaded implants during healing. A clinical resonance-frequency analysis study with sandblasted-and-etched ITI implants
    Bischof, M
    Nedir, R
    Szmukler-Moncler, S
    Bernard, JP
    Samson, J
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) : 529 - 539
  • [9] BOYNE PJ, 1980, J ORAL SURG, V38, P613
  • [10] Autogenous onlay bone grafts vs. alveolar distraction osteogenesis for the correction of vertically deficient edentulous ridges: a 2-4-year prospective study on humans
    Chiapasco, Matteo
    Zaniboni, Marco
    Rimondini, Lia
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (04) : 432 - 440