Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle

被引:12
作者
Huang, Shengwei [1 ]
Li, Chengzhou [1 ]
Tan, Tianyu [1 ]
Fu, Peng [2 ]
Wang, Ligang [3 ]
Yang, Yongping [1 ]
机构
[1] North China Elect Power Univ, Natl Res Ctr Thermal Power Engn & Technol, Beijing 102206, Peoples R China
[2] Shenhua Guohua Beijing Elect Power Res Inst, Beijing 100025, Peoples R China
[3] Swiss Fed Inst Technol Lausanne, Ind Proc & Energy Syst Engn, CH-1951 Sion, Switzerland
关键词
coal-fired power plants; waste heat utilization; organic Rankine cycle; exergy analysis; in-depth boiler-turbine integration; SUPERSTRUCTURE-FREE SYNTHESIS; LOW-PRESSURE ECONOMIZER; AIR-COOLING CONDENSER; FLUE-GAS; THERMODYNAMIC ANALYSIS; RECOVERY SYSTEM; OPTIMIZATION; TEMPERATURE; PERFORMANCE; ORC;
D O I
10.3390/e20020089
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
To maximize the system-level heat integration, three retrofit concepts of waste heat recovery via organic Rankine cycle (ORC), in-depth boiler-turbine integration, and coupling of both are proposed, analyzed and comprehensively compared in terms of thermodynamic and economic performances. For thermodynamic analysis, exergy analysis is employed with grand composite curves illustrated to identify how the systems are fundamentally and quantitatively improved, and to highlight key processes for system improvement. For economic analysis, annual revenue and investment payback period are calculated based on the estimation of capital investment of each component to identify the economic feasibility and competitiveness of each retrofit concept proposed. The results show that the in-depth boiler-turbine integration achieves a better temperature match of heat flows involved for different fluids and multi-stage air preheating, thus a significant improvement of power output (23.99 MW), which is much larger than that of the system with only ORC (6.49 MW). This is mainly due to the limitation of the ultra-low temperature (from 135 to 75 degrees C) heat available from the flue gas for ORC. The thermodynamic improvement is mostly contributed by the reduction of exergy destruction within the boiler subsystem, which is eventually converted to mechanical power; while the exergy destruction within the turbine system is almost not changed for the three concepts. The selection of ORC working fluids is performed to maximize the power output. Due to the low-grade heat source, the cycle with R11 offers the largest additional net power generation but is not significantly better than the other preselected working fluids. Economically, the in-depth boiler-turbine integration is the most economic completive solution with a payback period of only 0.78 year. The ORC concept is less attractive for a sole application due to a long payback time (2.26 years). However, by coupling both concepts, a net power output of 26.51 MW and a payback time of almost one year are achieved, which may promote the large-scale production and deployment of ORC with a cost reduction and competitiveness enhancement.
引用
收藏
页数:22
相关论文
共 87 条
[31]   A new principle of synthetic cascade utilization of chemical energy and physical energy [J].
Jin, HG ;
Hong, H ;
Wang, BQ ;
Han, W ;
Lin, RM .
SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 (02) :163-179
[32]   Low-Rank Coal Drying TechnologiesCurrent Status and New Developments [J].
Karthikeyan, Muthusamy ;
Wu Zhonghua ;
Mujumdar, Arun S. .
DRYING TECHNOLOGY, 2009, 27 (03) :403-415
[33]   Generic superstructure synthesis of organic Rankine cycles for waste heat recovery in industrial processes [J].
Kermani, Maziar ;
Wallerand, Anna S. ;
Kantor, Ivan D. ;
Marechal, Francois .
APPLIED ENERGY, 2018, 212 :1203-1225
[34]   A MODIFIED DOUBLE REHEAT CYCLE [J].
Kjaer, Sven ;
Drinhaus, Frank .
ASME POWER CONFERENCE, 2010, 2010, :285-293
[35]   Thermodynamic and economic analysis of a supercritical and an ultracritical oxy-type power plant without and with waste heat recovery [J].
Kotowicz, Janusz ;
Michalski, Sebastian .
APPLIED ENERGY, 2016, 179 :806-820
[36]  
Kreutz T, 2005, INT J HYDROGEN ENERG, V30, P769, DOI 10.1016/j.ijhydene.2004.08.001
[37]   A data-driven model for the air-cooling condenser of thermal power plants based on data reconciliation and support vector regression [J].
Li, Xiaoen ;
Wang, Ningling ;
Wang, Ligang ;
Kantor, Ivan ;
Robineau, Jean-Loup ;
Yang, Yongping ;
Marechal, Francois .
APPLIED THERMAL ENGINEERING, 2018, 129 :1496-1507
[38]   Identification of optimal operating strategy of direct air-cooling condenser for Rankine cycle based power plants [J].
Li, Xiaoen ;
Wang, Ningling ;
Wang, Ligang ;
Yang, Yongping ;
Marechal, Francois .
APPLIED ENERGY, 2018, 209 :153-166
[39]   Economical evaluation and optimization of subcritical organic Rankine cycle based on temperature matching analysis [J].
Li, You-Rong ;
Du, Mei-Tang ;
Wu, Chun-Mei ;
Wu, Shuang-Ying ;
Liu, Chao ;
Xu, Jin-Liang .
ENERGY, 2014, 68 :238-247
[40]   Influence of coupled pinch point temperature difference and evaporation temperature on performance of organic Rankine cycle [J].
Li, You-Rong ;
Wang, Jian-Ning ;
Du, Mei-Tang .
ENERGY, 2012, 42 (01) :503-509