A numerical imperfection sensitivity study of cold-formed thin-walled tubular steel columns at uniform elevated temperatures

被引:38
|
作者
Feng, M
Wang, YC
Davies, JM
机构
[1] Univ Manchester, Ctr Civil & Construct Engn, Manchester M60 1QD, Lancs, England
[2] UMIST, Manchester M60 1QD, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
cold-formed structures; axial strength; design method; initial imperfection; local buckling; flexural buckling; fire resistance;
D O I
10.1016/j.tws.2003.12.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A numerical study is carried out on cold-formed rectangular hollow section columns to evaluate the sensitivity of column failure strength to initial imperfections, stress-strain relationships and to assess the existing design methods. It is shown that the magnitude of initial local buckling imperfection has a significant effect on the ultimate strength of short columns where failure is predominantly local buckling. Its effect on long columns is relatively small. Similarly the magnitude of initial global imperfection has more influence on the ultimate strength of a long column, whose failure is governed by global buckling, than on short columns, where local buckling controls. The shape of the stress-strain relationship of cold-formed steel will have noticeable effect on the column failure load. Current design methods, for high temperatures in ENV1993-1-2 and for ambient temperature in ENV1993-1-3, can provide a valid basis of calculation but modification will be necessary, depending on the exact model of stress-strain relationship of cold-formed steel at elevated temperatures. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:533 / 555
页数:23
相关论文
共 50 条
  • [21] Global buckling analysis on cold-formed steel built-up box-shape columns at ambient and elevated temperatures
    Yang, Jingjie
    Wang, Weiyong
    Xu, Lei
    Shi, Yu
    STRUCTURES, 2023, 57
  • [22] Optimization of Cold-Formed Thin-Walled Cross-Sections in Portal Frames
    Stulpinas, Mantas
    Daniunas, Alfonsas
    BUILDINGS, 2024, 14 (08)
  • [23] Structural design of cold-formed stainless steel tubular X- and T-joints at elevated temperatures
    Lan, Xiaoyi
    Huang, Yuner
    THIN-WALLED STRUCTURES, 2016, 108 : 270 - 279
  • [24] An experimental study of loaded full-scale cold-formed thin-walled steel structural panels under fire conditions
    Feng, M
    Wang, YC
    FIRE SAFETY JOURNAL, 2005, 40 (01) : 43 - 63
  • [25] EXPERIMENTAL INVESTIGATION AND DESIGN OF CONCRETE-FILLED COLD-FORMED THIN-WALLED STEEL TUBES SUBJECT TO BENDING
    Jiang, Aoyu
    Chen, Ju
    Jin, Weiliang
    PROCEEDINGS OF THE TWELFTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS I AND II, 2012, : 855 - 861
  • [26] Buckling Strength of Cold-Formed Stiffened Thin-Walled Steel Box Bridge Piers under Cyclic Loading
    Mamaghani, Iraj H. P.
    Mwaura, Njiru
    EUROPEAN ASSOCIATION ON QUALITY CONTROL OF BRIDGES AND STRUCTURES, EUROSTRUCT 2023, VOL 6, ISS 5, 2023, : 1291 - 1294
  • [27] Buckling analysis of thin-walled cold-formed steel structural members using complex finite strip method
    Naderian, H. R.
    Ronagh, H. R.
    THIN-WALLED STRUCTURES, 2015, 90 : 74 - 83
  • [28] Cold-formed ferritic stainless steel perforated tubular stub columns: Behaviour and design
    Anbarasu, M.
    Subalakshmi, M.
    Dar, M. Adil
    Hassanein, M. F.
    THIN-WALLED STRUCTURES, 2022, 170
  • [29] Local buckling studies of cold-formed steel compression members at elevated temperatures
    Gunalan, Shanmuganathan
    Heva, Yasintha Bandula
    Mahendran, Mahen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 108 : 31 - 45
  • [30] Buckling and optimal design of cold-formed thin-walled beams: Review of selected problems
    Magnucka-Blandzi, E.
    Magnucki, K.
    THIN-WALLED STRUCTURES, 2011, 49 (05) : 554 - 561